|
|
|
|
|
Test & Measuring Instruments
(Showing headlines 11921 - 11940) << 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 ...
|
 FieldPoint Modules deliver fast analog I/O.National Instruments Corp.
Austin, TX 78759-3504
Aug 16, 2004 Suited for systems that require accurate manipulation of analog measurements, Compact FieldPoint and FieldPoint analog modules deliver analog inputs with 16-bit resolution and combination analog I/O. Models cFP-AI-112 and FP-AI-112 are 16-bit, 16-channel analog input modules, while cFP-AIO-610 and FP-AIO-610 are 12-bit, 4-input/4-output analog I/O modules. They feature balanced input and output channel count and 1.4 kHz update rate. |
 Wireless Temperature Recorder permits real-time monitoring.MadgeTech
Warner, NH 03278
Aug 16, 2004 Portable, 2-channel Model RF TC4000A Thermocouple Recorder and Wireless Transmitter can record up to 4,095 readings per channel and display data in real-time while continuing to log. Capable of transmitting information to receiver located up to 1 mile away using repeater, compact device is compatible with all common thermocouples and provides NIST-calibrated accuracy of ±0.5°C. Battery-powered unit can be started, stopped, and configured directly from computer. |
 Data Acquisition System works with handhelds and laptops.Analog & Digital Peripherals, Inc. (ADPI)
Troy, OH 45373 0499
Aug 13, 2004 Designed for Windows tablet and laptop computers, DATAQ CF2 consists of universal virtual instrument package and DAQ system. It incorporates 24-bit compact flash card with 32 Kb RAM; sleep mode; and programmable Pocket PC Test Panel Software, which enables users to acquire, analyze, store, and view data. Data can be imported into software using Labview 7 and Express, and Excel, Access, and MATLAB, or analyzed scientifically with C++ using FFT's. |
 Image Analyzer suits column chromatography applications.Malvern Instruments Inc.
Westborough, MA 01581
Aug 13, 2004
Flow Particle Image Analyzer, Model FPIA-2100 provides information on particle size, shape, and distribution of packing materials for column chromatography. Digital image analysis helps trace non-spherical particles that regularly occur if operating pressure is raised too high. Instrument produces scattergram plots of size against shape, which provide method of fingerprinting materials, enabling visual comparisons to be made between samples.
|
 Digital Crane Scale withstands induced torque.Measurement Systems International, Inc. (MSI)
Seattle, WA 98168 4660
Aug 13, 2004 Porta-Weigh Plus MSI-9300HT Hi-Torque RF Scale is suited for situations where powered rotation of lifted material is required. With options for top and bottom attachments, unit comes in 4 models with capacities to 35 tons. It provides wireless data-gathering network suitable for process control, safety monitoring, and data collection. RF transmission of real-time weight and product information can be networked and communicated to CellScale indicators and modems. |
 Temperature Sensors come in 3 application categories.Endress + Hauser Inc.
Greenwood, IN 46143
Aug 13, 2004 General-purpose sensors are suited for use in all types of manufacturing and HVAC applications as well as factory automation, while heavy-duty sensors are designed for oil and gas, offshore, petrochemical, and power industries. Conforming to 3-A sanitary standards, sanitary sensors suit clean-in place (CIP) and sterilize-in-place (SIP) environments. |
 Tachometer offers contact and non-contact functionality.E Instruments International LLC
Langhorne, PA 19047
Aug 13, 2004
Suited for use in HVAC industry, handheld Mini Speed Pro - CT50 is designed one-hand operation and is accurate to ±1% of reading. Portable, compact unit, able to operate as optical or contact tachometer, has dual display that continuously shows measurement, data hold, and min and max values. Protective rubber boot is available.
|
Meter measures energy consumption in singlephase services.GE Energy
Atlanta, GA 30339
Aug 12, 2004 Type I-210â„¢ electronic watt-hour meter delivers solid-state measurement performance through its sensor design and mechanical construction. It meets or exceeds ANSI® industry standards with 60 Hz model, which operates at 120 and 240 Vac for Class 20, 100, 200, and 320 socket-based residential or commercial installations. Unit measures energy consumption in 2- or 3-wire transformer-rated or self-contained residential or commercial singlephase services. |
 Data Acquisition Board offers update rates to 100 kS/s.Measurement Computing Corp.
Norton, MA 02766
Aug 12, 2004
Fully supported by LabVIEW, SoftWIRE, Agilent VEE, and MATLAB, PCI-DAS6031 board provides 64 single-ended or 32 differential channels of 16-bit analog input in addition to dual 16-bit analog outputs. Measurements on any of 14 input ranges may be taken at max sampling rate. Equipped with two 16-bit counter/timers, board has 8 digital, bi-directional I/O lines that can control relays and solenoids and monitor switch and contact closures.
|
 Terminal Modules feature increased packing density.Beckhoff Automation LLC
Minneapolis, MN 55337
Aug 11, 2004 KMxxxx Terminal Modules combine 16, 32, or 64 digital inputs or outputs in compact, slimline units, resulting in smaller control cabinets and terminal boxes. Compatible with all common fieldbuses, modules can be integrated into I/O system and connected with internal terminal bus. Bus Terminals with 1, 2, 4, or 8 channels are 12 mm wide and enable bit-precise configuration of required I/O channels. |
 Signal Interface Modules have up to 8 inputs per unit.Heim Data Systems, Inc.
Belmar, NJ 07719
Aug 11, 2004 Compact modules in D5000 Series, designed for acquisition of video and PCM and avionics bus data, offer plug-in functionality for operation in systems producing DATaRec-3 and IRIG-106 Chapter 10 data format. Each PCM module can record and replay from up to 8 data streams, with each stream having independent configuration and data rates up to 20 Mbps. Contained within aluminum housing, modules record data with high-resolution time tagging and provide multi-mission operation. |
 Pressure Transducer offers submersible operation.Setra Systems, Inc.
Boxborough, MA 01719
Aug 11, 2004 Utilizing CVD technology, Model 526 strain gauge pressure transducer features thick diaphragm for general-purpose industrial and submersible applications. It offers 0.25% FS accuracy and compensated temperature range of –5 to +180°F. Gauge pressure ranges from –14.7 to 6,000 psi, while absolute or compound pressure ranges from –14.7 to 300 psi. Modular design is offered in choice of millivolt, voltage, or current outputs over almost any pressure range. |
 Temperature Probes meet small space requirements.Selco Products Co.
Reno, NV 89521-5908
Aug 11, 2004
Featuring accuracy to ±0.1°C, miniature Series LSMN is available in 0.035 in. dia with 0.250 in. length and 0.055 in. dia with nominal 0.125-0.375 in. length. Units feature epoxy-filled polyimide tube and 28 AWG Kynar® insulation or 32 AWG Poly/Nylon insulation. They offer intermittent cycling capability at temperatures from -50 to +150°C. Dissipation constants are 1.5 mW/°C in still air and 10 mW/°C in stirred oil.
|
 Loadstring Adjustment System ensures accurate test data.Instron Corporation
Canton, MA 02021 1089
Aug 11, 2004 AlignPROâ„¢, designed to provide real-time concentricity and angularity adjustment under load, measures unwanted specimen bending due to loadstring misalignment. Compliant with ASTM E 1012 standards, it ensures that load string is correctly aligned before testing. System consists of alignment fixture, strain-gauged specimen, software, and electronics. Compact, portable electronics can be carried from machine to machine. |
Spectrum Analyzers have EMI measurement capability.Agilent Technologies, Inc.
Santa Clara, CA 95051
Aug 11, 2004
Designed to perform EMI precompliance measurements, PSA Series analyzers come standard with peak, average, and quasi-peak detectors and 6 dB resolution bandwidths of 200 Hz, 9 kHz, and 120 kHz. They are compliant with International Special Committee on Radio Perturbations and offer compliant MIL-STD bandwidths and detectors. PSA displays up to 3 detected traces, and all detected EMI signals appear in single display.
|
 Tester measures DOI on small and curved parts.BYK Gardner USA
Columbia, MD 21046 2729
Aug 10, 2004 Micro-wave-scan allows measuring of orange peel and distinctness of image (DOI) on automotive add-on parts such as bumpers, gas tank doors, mirror housings, or motorcycle parts. Unit objectively measures for brilliance and gloss, independent of paint system and curvature of surface. Large display shows complete statistics and allows input of alphanumeric names. Instrument includes docking station for recharging battery pack and transferring saved data to PC. |
 Optical System measures turbidity in process liquids.Mettler-Toledo Ingold
Bedford, MA 01730
Aug 10, 2004 Optical Turbidity System consists of Trb8300 F/S transmitter and InPro8400 and InPro8500 sensors. Forward scattered light technique of InPro8400 sensor enables measurements in liquids which appear clear to human eye. Combined forward/90° scattered light technique of InPro8500 sensor makes it possible to distinguish between turbidity caused by colloidal particles or larger particles. Both flow-through sensors can be installed in main pipes or bypass line. |
 Paperless Recorder displays up to 18 channels of data.Fuji Electric Corp. Of America
Saddle Brook, NJ 07663
Aug 10, 2004 PHL Paperless Recorder displays multiple channels of data on 5.7 in. TFT color LCD and lets users switch between display modes via 8-key front panel. Unit comes with 9 channels, scalable to 18, and records up to 12 types of thermocouples, 5 types of resistance bulbs, and dc voltage/current input. PC support software allows configuration from PC, monitoring of real-time data, and viewing of historical data. Unit comes with math and totalizing functions. |
 Gauging Sensor Head suits limited work envelopes.LMI Technologies Inc.
Southfield, MI 48075
Aug 10, 2004
Based on laser triangulation, Selcom® SLS 2401 offers stand-off distance of 1.97 or 3.15 in., depending on model, measuring range of 0.8 or 3.15 in., and spot size of 0.002 or 0.004 in. Class IIIb and optional Class II and Class 3R PSD-based unit features microprocessor-based Fast Light Control Circuit, which reacts in less than 8 µs for error-free measurements up to 16,000 times/sec. It includes 16 kHz sampling rate as well as RS232, RS422, and high-speed RS-422 digital outputs.
|
Bonding Meter is intrinsically safe.PPM, Inc.
Cleveland, OH 44122
Aug 10, 2004 Bearing ATEX directive, UL, CSA, and CE markings, Model R1L-E2 Ruggedized Ohmmeter/Bonding Meter provides safe measurement of mechanical and electrical bonds in explosive environments. Applications include diesel or jet-fuel storage units, fuel tanks and system components, and transport lines where explosive fumes might create hazard for operators using standard test instruments. |
(Showing headlines 11921 - 11940) << 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754
|
|
|