|
|
|
|
|
Test & Measuring Instruments
(Showing headlines 11101 - 11120) << 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 ...
|
 Digital-to-Synchro Converters require +5 Vdc input power.Computer Conversions Corp.
East Northport, NY 11731
May 20, 2005 Measuring 2.6 x 3.1 x .51 in., reference-powered Digital-to-Synchro Converter modules accept 14-bit natural binary angle and convert it into 3-wire synchro signal. Output is short circuit proof and current limited with transient protection and thermal cutoff. Units rated at 400 Hz have 4.5 Va load capability, while 60 Hz units feature 2 Va capability. All utilize thermally conductive encapsulant and metal top plate. Operating temperatures are 0–70°C or -55 to +90°C. |
 Battery-Operated Flowmeter is suited for water industry.Siemens Energy & Automation, Inc., Spring House Location
Spring House, PA 19477-0900
May 20, 2005 With typ battery life of 6 years, MAG 8000 W measures flow in both directions to provide both leak detection and billing information with precision of 0.5%. It features internal sensor coned-down design, has no moving parts, and is rated NEMA 6P. Integrated data logger stores consumption figures up to 26 months, along with alarm signals of special events. Unit can be integrated into recording systems via its integral IR interface and 2 pulse outputs. |
Test Kit measures dyne levels.ADM Tronics Unlimited, Inc.
Northvale, NJ 07647 1904
May 20, 2005 Surface Energy Test Kit, VU-DYNE allows user to determine dyne levels of any film or substrate surface. Indicator solutions in kit are those commonly used for ink, coating, and adhesive wettability tests on films, especially for water-based products. Kit includes test board, test sheet, 2 wire-wound draw-down rods, 6 bottles of VU-Dyne Indicator Solution, and 6 dropper bottles. |
Digital I/O Module enables remote monitoring and control.Measurement Computing Corp.
Norton, MA 02766
May 20, 2005
Ethernet-based Measurement Advantage model E-PDISO16 offers PCI-based functionality with 16 isolated digital inputs, 500 Vdc isolation, and 16 form C relays with 6 A at 240 Vac/28 Vdc contact ratings. It can be distributed anywhere network connection and power exists. Users connect device to network at point of measurement and configure, monitor, and control device from anywhere else on network. Features include screw terminals, metal enclosure, and power supply.
|
Pressure Transmitter features compact design.Gefran ISI, Inc.
Winchester, MA 01890
May 20, 2005 Built to handle hydraulic, pneumatic, and process measurement applications, TK Series has design that is insensitive to mounting torque and resists RFI, corrosive media, and mechanical shock and vibration. It is offered with 6 different electrical connector options and choice of 5 Vdc, 10 Vdc, or 4–20 mA outputs. Available for pressures from vacuum to 0–7,500 psi, IP65/IP67-rated series has response time under 1 mS and accuracy of 0.3% FS output. |
 Rack Mount DAQ Recorder provides 8 channels.Astro-Med, Inc.
West Warwick, RI 02893
May 19, 2005 Dash 8XeR can simultaneously capture 8 analog channels and 4 scope channels at sample rate of 5 MHz per channel, for total of 12 channels of data acquisition. It features GBit Ethernet interface, on-board DVD burner, and 15 in. color monitor for touch-screen control and real-time data viewing and analysis. Compatibility with USB devices for data transfer is achieved through USB 2.0 port. Modular inputs allow each channel to be configured independently. |
 Test Tools combine insulation tester and multimeter.Fluke Corp.
Everett, WA 98203
May 19, 2005 Insulation Multimeter Models 1587 and 1577 combine 1 kV digital insulation tester with full-featured true-rms digital multimeter in single, handheld device that fits in toolbox or on tool belt. Model 1587 provides insulation resistance testing up to 2 GW with 5 output voltages from 50–1,000 V, while Model 1577 tests up to 600 MW of resistance with 500 or 1,000 V. Insulation testing is disabled if meters are connected to live circuit with more than 30 V. |
 Fluorescence Detector simultaneously detects 4 samples.McPherson, Inc.
Chelmsford, MA 01824
May 19, 2005 Quad-channel filter fluorometer gathers data for atmospheric photochemistry to determine effects of pollution on climate and air quality. It uses line emission light sources and band filters for discrete wavelength excitation and is compatible with 6–24 µL HPLC flow cells. Configurable for series or parallel detection, unit employs 4 photomultiplier detectors and provides consolidated control of output amplifier time constant and photomultiplier voltage. |
 Multi-Parameter Test Kit is fiber-optic based.Fiso Technologies Inc.
Quebec, QC G2E 5R9 Canada
May 19, 2005 Dynamic Multi-Parameter Test Kit comes with BUS Commander Software and variety of Fabry-Perot fiber optic sensors, including temperature, pressure, strain, and refractive index sensors. BUS signal conditioner and acquisition system is configured with 2 channels, offering simultaneous reading with sampling rate to 1,000 Hz. System is upgradeable to up 8 channels per chassis, can be cascaded, and can be controlled from remote computer. |
 Spectrophotometer uses electronic and diode array technology.AMETEK Process Instruments
Newark, DE 19702
May 19, 2005 Suited for UV-VIS spectroscopy of liquids and gases, Model IPS-4 can measure up to 8 wavelengths and quantify 5 measurement components simultaneously. It comes with chemometric capability to solve complex measurement problems, has no moving parts, and offers full spectral acquisition from 220–1,100 nm. Utilizing Xenon lamp, self-aligning unit includes analog and digital communications capabilities, built-in web browser, and 4-line VFD display. |
 Multifunction Module enables isolated signal conditioning.IOtech, Inc.
Bedford Heights, OH 44146-1833
May 19, 2005 Using 8B isolated signal conditioning modules, DBK48™ provides up to 16 channels of I/O with 250 V isolation from channel-to-channel. Up to 16 modules can attach to one P1 expansion port on IOtech DAQ products. All signal connections are accomplished via removable screw-terminal connectors on front panel. Product incorporates cold junction compensation and dc/dc converter. Modules are available for measuring volts, thermocouples, RTDs, current, and strain gages. |
 Video Inspection System is designed for steel mills.Unilux, Inc.
Saddle Brook, NJ 07663
May 19, 2005 Available as single- or double-sided remote inspection system, Q-EYE enables one inspector to spot defects as small as 0.04 in. across 60 in. wide strip at speeds to 4,400 fpm in real time. Menu-driven software enables unit to be programmed for video capture, storage, and replay. System uses Unilux inspection lights and two 8-bit black and white cameras with video resolution of 1,392 x 1,040 pixels and comes with 20 in. flat-panel monitor. |
 Digital Multimeter measures 4.9 x 2.4 x .9 in.Ideal Industries, Inc.
Sycamore, IL 60178
May 19, 2005 With built-in leads that store snugly behind built-in test stand, PocketPro™ fits inside pants or shirt pocket. Three buttons and thumb switch allow electrician to select between continuity/resistance, diode, and ac/dc voltage testing, as well as cycle through test ranges and hold measurement. Unit includes 3.5 digit LCD screen, overload protection on all ranges, audible continuity, low battery indicator, and auto power off. |
Biaxial Inclinometers suit automation applications.FRABA Inc.
Hamilton, NJ 08609-2020
May 19, 2005
Offered with measuring range of ±5°, 15°, or 30°, AnguSens inclinometers are manufactured in IP66 metal housing and incorporate customizable filters along with microcontroller. Sensors feature 3-point support on casing for safe hold and come equipped with RS232 or CANbus interface combined with analog output for current, voltage, or PWM. Internally, incline is measured 100 times/sec, filtered, and output at 10 readings/sec.
|
 Wireless I/O System utilizes FHSS technology.Phoenix Contact
Harrisburg, PA 17111 0100
May 18, 2005 Multipoint-to-point Model RAD-ISM-900-BD-BUS brings multiple channels of I/O from up to 8 remote locations back to one master station. Bi-directional feature enables use of device in monitoring and control applications and eliminates cable and conduit for analog and digital signals in harsh industrial environments. Typical in-plant range is 600–1,000 ft with no line of sight. Transceivers and I/O modules are featured in 22.5 mm DIN-rail mount housing. |
 Rotary Position Systems work in hazardous environments.BEI Sensors (BEI Industrial Encoders)
Goleta, CA 93117
May 18, 2005
Intrinsically Safe (IS) rotary position and speed sensing system meets international CENELEC/ATEX ratings. Rotary encoder, cable assembly, and intrinsic safety barrier components combine to satisfy requirements for loop-approved, Class I, Division 1, Group A, B, C, and D sensing system. Built with BEI IS components, system can provide precision position measurement in wireline, slickline, logging, drawworks, coiled tubing, blenders, and power tong applications.
|
 Compact Absolute Encoder delivers 12 bits of resolution.CUI, Inc.
Tualatin, OR 97062
May 17, 2005
Designed for limited-space applications, MAS42 and MAH42 measure 52 mm dia x 30 mm high and are available in shaft and hollow shaft versions with 6 mm shaft diameter and 10 mm bore diameter respectively. Units deliver 8 bits (256 PPR) to 12 bits (4096 PPR) of absolute position information with gray code, natural binary, or BDC output. Capable of operating within -10 to +70şC, units measure rotary process up to 6,000 rpm.
|
 Electrostatic Voltmeter features non-contact design.Trek, Inc.
Medina, NY 14103 9710
May 17, 2005 Built to measure and monitor electrostatic charge, Model 400 incorporates vibrating reed probe sensor and noise null control potentiometer. It can be used with single chopper probe or dual chopper probe, which provides response time of less than 200 µsec for 1 kV step response with zero phase lag. There is no overshoot or undershoot when measuring step voltage changes, and measurement accuracy is better than ±0.05% of reading ±0.5 V at monitor output. |
 Development Kit works with high-voltage DACs.Goal Semiconductor Inc.
Montreal, QC H3B 1H4 Canada
May 17, 2005 HVDAC DevKit, model UVK-HVDAC200-4, provides plug-and-play platform for evaluation and prototype development using HVDAC200-4 quad, 9-bit, serially configurable voltage/current DAC with outputs of up to 200 V. Kit comes with Windows®-based demo program and consists of Goal VERSA MIX 8051 MCU, onboard voltage reference, and 2 adjustment potentiometers. Kit also offers over-temperature and temperature-sensor-threshold adjustment, terminal block, and PLCC-44 socket. |
 Sample Cell is designed for LA-ICP-MS applications.New Wave Research
Fremont, CA 94539
May 17, 2005 Used to provides aerosol washout and transient signal analysis, SuperCell™ features 18.5 cm˛ work area that accommodates multiple samples and standards simultaneously. When analyzing single-pulse, transient signals, design reduces aerosol dispersion, compressing and amplifying analytical information. For steady-state acquisitions, when sample is continuously ablated, unit displays typical signal rise times and rinse times of less than few seconds each. |
(Showing headlines 11101 - 11120) << 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756
|
|
|