Test & Measuring Instruments
(Showing headlines 10881 - 10900) << 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 ...
|
 Dewpoint Transmitter displays trends and history.Vaisala, Inc.
Woburn, MA 01801 1008
Jul 29, 2005 Comprised of 4 models, DRYCAP® Dewpoint Transmitter Series DMT340 features numerical and graphical display with multilingual interface that lets users monitor measurement trends and view up to 1-year history. Product covers industrial dewpoint measurements down to -60°C Td, with ±2°C accuracy, and incorporates condensation-resistant DRYCAP® Sensor. Along with auto-calibration, series features choice of analog outputs, serial interfaces, and alarm relays. |
 Flame Detectors provide high false alarm immunity.General Monitors
Lake Forest, CA 92630
Jul 29, 2005
Microcontroller-based, ATEX-approved UV/IR Model FL3110 and UV Model FL3111 include flicker-discrimination circuitry and self-checking continuous optical path monitoring to ensure fire protection. Both feature segregated wiring compartment where field terminations can be made without exposing ex-proof section to elements. Electronics are integral within stainless steel explosion-proof housing, allowing information to be processed at point of detection.
|
 Digital I/O USB Modules come in pin connector versions.Measurement Computing Corp.
Norton, MA 02766
Jul 28, 2005
Based on industry standard 82C55, 2.77 x 3.2 x 0.5 in. modules use 37-pin connectors that facilitate switching from PCI to USB in existing applications. Model USB-DIO24/37 offers 24 bits of logic level digital I/O, while USB-DIO24H/37 offers 24 bits of DIO with 15 mA source, 64 mA sink output capability. Both products are USB 1.1 and 2.0 compatible, incorporate 32-bit external event counter, and are supported under MS Windows 98SE/ME/2000/XP.
|
 Digital Multimeters feature single probe detection.Greenlee Textron, Inc.
Rockford, IL 61109
Jul 28, 2005 Comprised of 4 auto-ranging TRMS and averaging multimeters, DM-300 series carries UL safety ratings of Category IV 600V and Category III 1000V. All models offer non-contact detection and can measure ac and dc voltage, check diodes, and verify continuity. Models DM-310, DM-330 and DM-350 multimeters are capable of measuring ac and dc current and capacitance and have input error warning. Model DM-350 adds low current measurement feature and backlit display. |
DeviceNet Interface Cards come with software tools.Woodhead Canada Ltd. / SST
Waterloo On N2V 1n3, CD Canada
Jul 28, 2005 SST DeviceNet network interface cards are available with configuration console (SST-DN3-CNF), network analyzer (SST-DN3-DNA), and diagnostic tool (SST-DN3-DIA). Configuration console is used to configure DeviceNet network and OPC Server, while network analyzer captures DeviceNet network activity to aid in troubleshooting and diagnosing device problems. Diagnostic tool provides card initialization tools and diagnostic information on scanner related activity. |
 LC/MS System features metal capillary electrospray probe.Shimadzu Scientific Instruments, Inc.
Columbia, MD 21046
Jul 27, 2005 Liquid Chromatograph/Mass Spectrometer, Model LCMS-2010EV incorporates ion source design that uses additional drying gas at inlet of capillary for greater control of solvent adduct formation. Ion optical system consists of Q-array design, Octopole lens, and Hyperbolic Quadrupole rod system. Supplied as standard, ESI operates with flow rates up to 2 mL/min without flow splitting, and scanning electronics support 6,000 amu/sec acquisition rates. |
 Tool Recognition System uses laser to detect broken tools.Renishaw, Inc.
Hoffman Estates, IL 60192
Jul 27, 2005
Suited for high-speed detection in real machining conditions, System TRS1 uses Tool Recognition Technology to distinguish intact tools from broken tools including drills, taps, reamers, and end mills. Laser precision makes it effective with tools down to .019 in. dia. With operating range of 12-79 in. system can be mounted outside working envelope, and is suited for range of CNC machines, from large machining centers to small drilling systems.
|
 Light Analyzer combines integral and spectral measurement.Gigahertz-Optik Inc.
Newburyport, MA 01950 4009
Jul 27, 2005 Designed for photometric and colorimetric measurement of LEDs and other light sources, modular X4 works with PC under remote control operation via USB interface with supplied OS-X4 software. Unit simultaneously measures light signal integrally and spectrally with photopic detector and spectrometer, allowing on-line correction calculation to yield measurement uncertainty under 2%. Color coordinates are indicated with accuracy of less than 0.005. |
 Laser Meter includes PC host interface.Coherent Inc., Laser Group
Santa Clara, CA 95054-1112
Jul 27, 2005 Featuring analog output, FieldMaxII™ is available in power-only, energy-only, or power and energy configurations. Thermopile, pyroelectric, and semiconductor sensors enable unit to measure UV, visible, and IR laser output from nW to kW range, and to work with CW and pulsed lasers with repetition rates up to 300 Hz. LabVIEW Instrument driver and ActiveX DLL Server component facilitate development of custom testing routines and integration with other test equipment. |
 Spectrum Analyzer measures 3 distinct frequency bands.Berkeley Varitronics Systems
Metuchen, NJ 08840-1217
Jul 26, 2005 Interfacing with iPAQ® PocketPC®, RF-calibrated BumbleBee™ measures 2.400–2.500 GHz, 5.150–5.900 GHz, and FCC designated Public Safety band of 4.940–4.990 GHz. Spectrum analysis features include 3 waveform traces, peak hold, peak search, and user-selectable packet/interference triggers. Unit allows on-the-fly switching of bands for real-time spectral analysis of wireless standards including RFID, VoIP, 802.11, cordless phones/ video, and broadband public safety data networks. |
 USB Adapter turns PC into 2 MHz oscilloscope.Saelig Co., Inc.
Pittsford, NY 14534
Jul 26, 2005
Powered via its USB 2.0 interface, PicoScope 2202(TM) PC scope adapter features plug-and-play operation for any laptop or desktop PC running Microsoft Windows 98SE or above. Dual channel, USB oscilloscope has 20 MS/s, 8-bit sampling rate; 2 MHz bandwidth; ranges from ±50 mV to ±20 V; and 32 kB buffer memory. Supplied with PicoScope and PicoLog DAQ software, users get simultaneous oscilloscope, spectrum analyzer, and multimeter functions.
|
 Temperature/RH Data Logger offers USB connectivity.Saelig Co., Inc.
Pittsford, NY 14534
Jul 26, 2005
Able to record transit conditions, EL-USB-2 measures and stores up to 16,382 RH and 16,382 temperature readings over 0-100% RH and -31 to +176°F measurement ranges. User sets logging rate and start time and downloads stored data to PC via USB port. Once downloaded, data can be graphed, printed, and exported to other applications. IP67-rated unit comes with LED status indicators, configuration software, and 2 settable alarm thresholds.
|
 Data Logger records temperature and humidity.Pico Technology Ltd
St Neots Cambridge PE19 1QB United Kingdom
Jul 26, 2005 Combining environmental probe, ADC, and data logger, HumidiProbe® plugs into USB port for instant measurement of temperature and humidity. Up to 4 units can be connected to single PC, allowing user to monitor multiple locations at once. HumidiProbe measures temperatures from 0–70°C with ±0.5% accuracy, 0.01°C resolution, and response time of 5–30 sec. Relative humidity is measured from 0–100% with ±2% accuracy, 0.03% resolution, and 4 sec response time. |
 Geothermal DP Indicator Switch performs low flow monitoring.Mid-West Instrument
Sterling Heights, MI 48314
Jul 26, 2005 Featuring complete high to low side isolation, diaphragm type Model 522 is offered with body materials of aluminum or 316/316L stainless steel and 316 SS, ceramic, and acetal moving parts. It comes with one or 2 field-adjustable, 40–100% FS, hermetically sealed reed switches in SPST (3 A) configuration. Max static pressure is 1,000 psig, max differential over-range pressure is 200 psid, and DP ranges include 0–5 and 0–50 psid with ±5% FS accuracy. |
 Hour Meter displays readings with no tenths.Energy Kinetics, Inc.
Naperville, IL 60563
Jul 26, 2005 DC Hour Meter, Model EK-200-10SS-NT allows user to monitor hours of operation to nearest hour, with no tenths, eliminating potential for errors caused by misreading tenths as whole hours. Standard unit reads to 99,999 hours and has non-reset security. Operating from 8–32 Vdc, meter includes all steel SAE bezel bracket mount, stainless steel bezel, and spade terminals. |
 Liquid-Filled Pressure Gage has stainless steel design.Dwyer Instruments, Inc.
Michigan City, IN 46361
Jul 26, 2005
Used to overcome pressure spikes, vibration, and pulsation in mechanical applications, Series 64000 features 2˝ in. dia stainless steel housing, glycerin fill, and 316 stainless steel wetted parts. Unit is available in several ranges up to 300 psi and operates in temperatures to 150°F. Suited for applications such as pumps, compressors, hydraulic presses, machinery, and motors, chemically compatible design delivers ±1.6% FS ASME/ANSI Grade 1A accuracy.
|
 Linear Encoder System offers low thermal expansion.Renishaw, Inc.
Hoffman Estates, IL 60192
Jul 26, 2005
Made of Invar for thermal expansion of 1.3 µm/m/K, RELM linear scale intelligent encoder offers non-contact performance with accuracy to ±1 µm/m, resolution to 20 nm, and speeds above 10 m/s. System is comprised of SR readhead, Si interface, 20 µm RELM spar in defined lengths, and features such as SiGNUM(TM) intelligent signal processing and IN-TRAC(TM) auto-phase optical reference mark. SiGNUM(TM) software enables set-up and real-time system diagnostics via PC USB port.
|
 Pocket-Sized Meter indicates resistance and resistivity.Static Solutions, Inc.
Marlboro, MA 01752
Jul 26, 2005 Ohm-Stat™ RT-500 features built-in parallel electrodes on bottom of case to measure resistance to ground and surface resistivity. External banana jacks accept two 5 lb, 2.5 in. electrodes, which measure RTT, RTG, and volume resistance. RTT probes test small, difficult-to-reach surfaces, chairs, and smocks. With press of button, unit automatically measures 10 V or 100 constant V, depending on resistance of material. Colored LEDs test between 1E 3 and 1E12 ohms. |
Personal Dosimeter tracks exposure to workplace noise.Quest Technologies Inc.
Oconomowoc, WI 53066 4828
Jul 26, 2005 NoisePro® Series, combined with QuestSuite® Professional application software, enables users to proactively manage hearing loss caused by occupational noise over-exposure. While keeping history record, monitoring system provides real-time compliance indicators and optional vibrating alarms to promote self-management of noise exposures and HPD use. Analysis tools enable evaluation of engineering and administrative controls prior to purchase/implementation. |
 Diagnostic Tool detects automotive electrical faults.Snap-on Industrial
Kenosha, WI 53141 1410
Jul 25, 2005 Information-guided Vantage PRO™ combines automotive power graphic meter and 2-channel lab and ignition scope to capture and translate electrical component and diagnostic information and faults. Using Windows OS, Vantage PRO includes ARM processor, sunlight-readable color display, and expandable hardware architecture. It provides over 2 million vehicle-specific component tests, including tests for engine, transmission, ABS, charging, transfer case, and suspension systems. |
(Showing headlines 10881 - 10900) << 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755
|
|
|