 I/O Module helps control off-road equipment functions.HED, Inc.
Hartford, WI 53027
Aug 05, 2005 Solid-state, microprocessor-based CL-411 enables users to monitor several functions and components of off-road equipment. Product, able to serve as master or slave, provides 16 analog, frequency, resistive dependant sensor, and digital inputs. Along with 20 outputs that include PWMs outputs as well as 15 A sourcing outputs, unit features 4 switch-to-ground harness codes for multiplexing, 2 J1939 CAN ports, and one RS232 port. |
 X-Ray Metrology Tool measures thickness from 1 nm to 10 µm.Bede
Durham DH1 1TW United Kingdom
Aug 04, 2005 BedeMetrixâ„¢-F delivers non-destructive film thickness measurement on patterned wafers through combined x-ray reflectivity and x-ray fluorescence. Small spot x-ray optics enable measurement on test pads and in scribe lines down to 100 µm for XRR and 30 µm for XRF. BedeMetrixâ„¢-F is available in 3 primary configurations for strained silicon, metal film structure determination, and high-speed thickness measurement. |
 Boards provide PCI data acquisition.IOtech, Inc.
Bedford Heights, OH 44146-1833
Aug 04, 2005 DaqBoard/3000â„¢ Series consists of 4 boards equipped with custom data acquistion engine capable of making analog measurements at 1 µs/channel, and concurrently reading digital and counter inputs, while generating up to four 1 MHz/16-bit analog waveform outputs plus digital pattern generation. Boards include 8 differential or 16 single-ended analog inputs, 24 high-speed digital I/O lines, and four 32-bit, 20 MHz counter input channels with quadrature encoder capability. |
 Steel Pressure Gage has 2.5 in. face.Dwyer Instruments, Inc.
Michigan City, IN 46361
Aug 04, 2005
Featuring dual English/metric scales and 1.6% FS accuracy, Series 62000M may be liquid filled in field without requiring separate kit. Product is manufactured with 304 stainless steel housing and brass wetted parts. Able to withstand ambient temperatures to 140°F and process temperatures to 248°F, gage is available for ranges from full vacuum to 300 psi. Series 62000MU is panel-mount unit with U-clamp bracket.
|
IR Emitter meets UL-268 standard for smoke detectors.Vishay Intertechnology, Inc.
Malvern, PA 19355 2143
Aug 04, 2005 Certified for use in fire-protective signaling systems, lead (Pb)-free TSAL6100X01 has narrow angle of half-intensity of 10°, forward voltage of 1.35 V @ 100 mA, and typ radiant intensity of 130 mW/sr @ 100 mA. It is compatible with lead-free processing in accordance with WEEE and RoHS and suitable for high pulse-current operation. Unit may be used in other applications such as remote controls and those relying on UL 268-compliant IR emitters. |
 Digital Signal Analyzer measures sound and vibration.National Instruments Corp.
Austin, TX 78759-3504
Aug 03, 2005 Featuring 102 dB dynamic range, IEPE signal conditioning, and 8 input channels with acquisition rates of 2-33.3 kS/s, cRIO-4408 DSA 24-bit DAQ device makes sound and vibration measurements from integrated electronic piezoelectric sensors. It offers communication through 10/100 Ethernet, and built-in analog and digital antialiasing filters automatically adjust according to sampling rate. Labview program is included for TCP/IP communication. |
 Digital Recorders feature removable drives.Heim Data Systems, Inc.
Belmar, NJ 07719
Aug 03, 2005 Suited for acquisition of sensitive data in secure establishments, Series GSR provides all-digital recording, flexible signal interfacing, and removable media. Rack-mounted, 256 Mbit/s units are capable of simultaneously acquiring multiple streams of data from ground, airborne, and satellite telemetry sources. Data retrieval may be via real-time reconstruction of original signal sources or by direct high-speed transfer of digital data to user's computing platform. |
 UV Intensity Labels measure UV doses from 0-1,500 mJ/cm².UV Process Supply, Inc.
Chicago, IL 60614-4805
Aug 03, 2005 CON-TROL-CURE® Labels are paper-thin, photochromatic, pressure-sensitive labels that change color upon receiving UV dose. Color change enables comparison to dose chart representing UV dose in millijoules. Once label has changed color, it will not continue to change unless exposed to more UV, and is not subject to increasing color changes at elevated temperatures. Labels are suited for web printing, sheet fed printing, exposure verification, and 3D curing. |
 Hollow Shaft Encoders are suited for use with motors.Elcis srl
Italy
Aug 03, 2005 Incremental encoders are equipped with internal coupling that compensates for axial and radial slack of motor shaft to which they are coupled. Available in 4–120 mm hollow shaft sizes, products offer resolutions from 1–900,000 ppr. Select models are designed for use in engine test rooms with up to 20,000 rpm and operating temperatures up to 100°C. Other models are suited for brushless motors, allowing zero search and clamping on motor shaft from rear. |
Stress Test Chambers are available in sizes from 8-64 ft³.Cincinnati Sub-Zero Products, Inc.
Cincinnati, OH 45241
Aug 03, 2005
Equipped with CSZ EZT-550 touch screen controller, Z-Plus temperature/humidity test chambers offer data logging with data access, graphical trending, and remote PC viewer. Roll out shelves support product loads without tipping, and remote software enables desktop monitoring and control. Environmental chambers, available in single stage (-34°C), Tundra® (-45°C), and cascade (-73°C) temperature ranges to 190°C, offer optional humidity range from 10-98% RH.
|
 PC/104 Utility Board offers 36 channels of I/O.ACCES I/O Products, Inc.
San Diego, CA 92121 1506
Aug 03, 2005 Delivering smooth, error-free data transmission, 104-II32-4RO provides connections to assortment of devices via 32 optically isolated digital inputs with change-of-state interrupt generation and 4 electromechanical relay outputs. Inputs may be driven by dc sources of 3–31 V or ac sources at frequencies of 40 Hz to 10 kHz. Along with switchable filters and schmitt trigger buffers, product features 10 µsec typ response time and 1.8 kΩ input impedance. |
Portable Temperature Logger offers USB communications.CAS Data Loggers
Chesterland, OH 44026
Aug 03, 2005
Battery-operated OQ610 accommodates K and T type thermocouple and has 6 input channels. Portable unit, set-up via 3-button operation or directly from PC, automatically detects when sensors are connected. Able to log up to 8 readings/sec, product can be configured to start and stop logging on time or temperature levels. SquirrelView software is included for configuring, downloading, displaying, and analyzing data.
|
 Precision RTD Recorder features wireless functionality.Omega Engineering, Inc.
Stamford, CT 06907
Aug 03, 2005
Battery-powered OM-CP-RFRTDTEMP101A incorporates wireless transmitter that, when enabled, transmits readings back to host computer for real-time data analysis. Readings are also logged to device memory for data security, and slide switch allows transmitter to be turned on or off without affecting device operation. Able to be started, stopped, and configured directly from computer, portable temperature recorder takes up to 5,461 measurements.
|
 Transmitters display dewpoint trends.Vaisala, Inc.
Woburn, MA 01801 1008
Aug 02, 2005 Suited for demanding applications, DRYCAP® Series DMT340 consists of 4 models covering dewpoint measurements down to -60°C Td with accuracy of ±2°C. Numerical and graphical display, with multilingual user interface, monitors measurement trends and up to 1-year history. Auto-calibration detects on-line measurement inaccuracies and automatically corrects dry-end drift in calibration curve. Units offer choice of analog outputs, serial interfaces, and alarm relays. |
 Waterproof Meter measures pH and conductivity.IQ Scientific Instruments, Inc.
San Diego, CA 92127
Aug 02, 2005 Equipped with non-glass pH probe and solid-state conductivity electrode, NEMA 4X-rated Model IQ170 measures pH, mV, temperature, ORP, conductivity, TDS, and salinity. It includes LCD display with LED backlight, automatic temperature compensation, automatic pH buffer recognition, automatic conductivity cell constant recognition with auto-ranging, and up to 3-point pH calibration. Stainless steel pH probe includes sensor that is virtually unbreakable. |
 Gas Flow Meters suit sanitary process applications.Fluid Components Intl.
San Marcos, CA 92069 5115
Jul 29, 2005 FlexMASSter high-purity Model ST98HP and ultra high-purity Model ST98UP feature 316L stainless steel, thermal mass flow sensing element with all-welded wetted surface and 10 or 15 Ra electro-polish finish. Meters offer flow range from 2.0–3,183 scfm in air with accuracy of ±1% of reading and ±0.5% FS. Housed in NEMA Type 4, Type 4X, or explosion-proof enclosure, transmitter can be integrally mounted to flow element or remotely mounted up to 500 ft. |
 Dewpoint Transmitter displays trends and history.Vaisala, Inc.
Woburn, MA 01801 1008
Jul 29, 2005 Comprised of 4 models, DRYCAP® Dewpoint Transmitter Series DMT340 features numerical and graphical display with multilingual interface that lets users monitor measurement trends and view up to 1-year history. Product covers industrial dewpoint measurements down to -60°C Td, with ±2°C accuracy, and incorporates condensation-resistant DRYCAP® Sensor. Along with auto-calibration, series features choice of analog outputs, serial interfaces, and alarm relays. |
 Flame Detectors provide high false alarm immunity.General Monitors
Lake Forest, CA 92630
Jul 29, 2005
Microcontroller-based, ATEX-approved UV/IR Model FL3110 and UV Model FL3111 include flicker-discrimination circuitry and self-checking continuous optical path monitoring to ensure fire protection. Both feature segregated wiring compartment where field terminations can be made without exposing ex-proof section to elements. Electronics are integral within stainless steel explosion-proof housing, allowing information to be processed at point of detection.
|
 Digital I/O USB Modules come in pin connector versions.Measurement Computing Corp.
Norton, MA 02766
Jul 28, 2005
Based on industry standard 82C55, 2.77 x 3.2 x 0.5 in. modules use 37-pin connectors that facilitate switching from PCI to USB in existing applications. Model USB-DIO24/37 offers 24 bits of logic level digital I/O, while USB-DIO24H/37 offers 24 bits of DIO with 15 mA source, 64 mA sink output capability. Both products are USB 1.1 and 2.0 compatible, incorporate 32-bit external event counter, and are supported under MS Windows 98SE/ME/2000/XP.
|
 Digital Multimeters feature single probe detection.Greenlee Textron, Inc.
Rockford, IL 61109
Jul 28, 2005 Comprised of 4 auto-ranging TRMS and averaging multimeters, DM-300 series carries UL safety ratings of Category IV 600V and Category III 1000V. All models offer non-contact detection and can measure ac and dc voltage, check diodes, and verify continuity. Models DM-310, DM-330 and DM-350 multimeters are capable of measuring ac and dc current and capacitance and have input error warning. Model DM-350 adds low current measurement feature and backlit display. |
(Showing headlines 10861 - 10880) << 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755
|
|
|