Gas and Chemical Sensors / Detectors

Carbon Control System suits non-conventional furnaces.
Gas and Chemical Sensors / Detectors

Carbon Control System suits non-conventional furnaces.

Sentinel-FCP pairs extractive lambda probe with Dual Pro dual-loop process controller. Lambda probe, capable of oxygen sensing from ppm up to 15% oxygen, draws sample from furnace and provides oxygen measure to controller, which calculates furnace atmosphere carbon levels and dewpoint. Unit then automatically adjusts trim gas and furnace temperature. Sentinel-FCP can be located remotely and is...

Read More »
ORP and pH Sensors have differential design.
Gas and Chemical Sensors / Detectors

ORP and pH Sensors have differential design.

Constructed with glass electrode that is not prone to chemical attack, WDS Series differential pH and ORP sensors transmit signals up to 3,000 ft and are resistant to ground loop problems. Sensors can be replaced if reference solution becomes contaminated or salt bridge becomes clogged. Reference electrode is constructed from pH glass and is embedded in pH 7 buffer within sensor behind porous,...

Read More »
ORP and pH Sensors have differential design.
Gas and Chemical Sensors / Detectors

ORP and pH Sensors have differential design.

Constructed with glass electrode that is not prone to chemical attack, WDS Series differential pH and ORP sensors transmit signals up to 3,000 ft and are resistant to ground loop problems. Sensors can be replaced if reference solution becomes contaminated or salt bridge becomes clogged. Reference electrode is constructed from pH glass and is embedded in pH 7 buffer within sensor behind porous,...

Read More »
Toxic and Combustible Gas Monitor has alarm function.
Gas and Chemical Sensors / Detectors

Toxic and Combustible Gas Monitor has alarm function.

Model SBG-200 monitors and detects gases such as ammonia, carbon monoxide, ethylene oxide, natural gas, hydrogen sulphide, chlorinated solvents, sulphide dioxide, and other toxic gases. It incorporates circuitry to prevent false alarms and allow maintenance-free operation. Flashing light and sound alarm functions can be calibrated to activate at specific set point. Unit operates on 115 Vac, 60...

Read More »
Toxic and Combustible Gas Monitor has alarm function.
Gas and Chemical Sensors / Detectors

Toxic and Combustible Gas Monitor has alarm function.

Model SBG-200 monitors and detects gases such as ammonia, carbon monoxide, ethylene oxide, natural gas, hydrogen sulphide, chlorinated solvents, sulphide dioxide, and other toxic gases. It incorporates circuitry to prevent false alarms and allow maintenance-free operation. Flashing light and sound alarm functions can be calibrated to activate at specific set point. Unit operates on 115 Vac, 60...

Read More »
Ammonia Gas Detectors have audible and visual alarms.
Gas and Chemical Sensors / Detectors

Ammonia Gas Detectors have audible and visual alarms.

Designed to measure ammonia gas on continuous monitoring basis, multipurpose detectors employ explosion-proof sensor elements rated for Class I Division I, Group A-B-C-D hazardous atmospheres. Wall-mount Model 51A26 has 0-1,000 ppm range; wall-mount Model 51A40 comes with remote probe that is reliable up to 1,000 ft from controller; and portable Model 51A45 has 0-1,000 ppm range. All units...

Read More »
Leak Detector measures over 20 different gases.
Gas and Chemical Sensors / Detectors

Leak Detector measures over 20 different gases.

Model 501AK pinpoints leaks of all combustible and many non-combustible toxic gases. Sensitivities of some gases are as low as 1 ppm. Unit features 3-position sensitivity switch, as well as audible alarm and battery test circuit. It uses four 1.5 V alkaline batteries and is supplied with carrying case. Three foot sensor extension is available for getting into hard-to-reach places.

Read More »
Leak Detector measures over 20 different gases.
Gas and Chemical Sensors / Detectors

Leak Detector measures over 20 different gases.

Model 501AK pinpoints leaks of all combustible and many non-combustible toxic gases. Sensitivities of some gases are as low as 1 ppm. Unit features 3-position sensitivity switch, as well as audible alarm and battery test circuit. It uses four 1.5 V alkaline batteries and is supplied with carrying case. Three foot sensor extension is available for getting into hard-to-reach places.

Read More »