Quantcast
 
Search for: Search what?
Nov 26, 2009  
 Sections
Latest New Product News
Industry Market Trends
Green & Clean News
Association & Government News
Adhesives and Sealants
Agricultural and Farming Products
Architectural and Civil Engineering Products
Automatic ID
Chemical Processing and Waste Management
Cleaning Products and Equipment
Communication Systems and Equipment
Computer Hardware and Peripherals
Construction Equipment and Supplies
Controls and Controllers
Display and Presentation Equipment
Electrical Equipment and Systems
Electronic Components and Devices
Explosives, Armaments and Weaponry
Fasteners and Hardware
Fluid and Gas Flow Equipment
Food Processing and Preparation
Health, Medical and Dental Supplies and Equipment
HVAC
Labels, Tags, Signage and Equipment
Laboratory and Research Supplies and Equipment
Lubricants
Machinery and Machining Tools
Material Handling and Storage
Materials and Material Processing
Mechanical Components and Assemblies
Mechanical Power Transmission
Mining, Oil Drilling & Refining
Mounting and Attaching Products
Non-Industrial Products
Optics and Photonics
Packaging Products & Equipment
Paints and Coatings
Plant Furnishings and Accessories
Portable Tools
Printing and Duplicating Equipment
Retail and Sales Equipment
Robotics
Safety and Security Equipment
Sensors, Monitors and Transducers
Services
Software
Test and Measuring Instruments
Textile Industry Products
Thermal and Heating Equipment
Timers and Clocks
Transportation Industry Products
Vision Systems
Waste Handling Equipment
Welding Equipment and Supplies
 Press Releases
Products in the News
Company News
Mergers & Acquisitions
People in the News
Literature & Websites
 Resources
News Delivery Options
Browse Categories
Browse Companies
Mobile Edition
PR Resources
Licensing
Advertising
How to Write an effective Press Release
Trade Associations
Small Business Support
MEP

Advertisement
Sensors Monitors & Transducers -> Monitors -> Multipurpose Monitors


Multipurpose Monitors


   Add to Google      PDF icon

(Showing headlines 21 - 40)   1 2 3
Electron Beam Monitor measures high pulse currents.

Electron Beam Monitor measures high pulse currents.

Ion Physics Corp.
Fremont, NH 03044
Jan 04, 2007 Able to measure pulse currents up to 50,000 A, CM-1-E-beam current transformer combines 10 nanosecond risetime and 10 mV/A output sensitivity. It is constructed to operate in either vacuum or atmospheric pressure and has 8 in. ID and 12 in. OD. While designed as E-beam monitor, unit can also measure high-frequency transients on conductor carrying high dc or ac currents with minor modifications.

Under/Overvoltage Monitor suits tight-space applications.

Under/Overvoltage Monitor suits tight-space applications.

Linear Technology Corp.
Milpitas, CA 95035-7417
Dec 06, 2006 Supplied in 8-lead ThinSOT(TM) or 3 x 2 mm DFN package, LTC2912 features voltage monitoring inputs with filtering to reject brief glitches and minimize false or noisy triggering. Undervoltage (UV) and overvoltage (OV) trip thresholds, programmed by external resistors, exhibit ±1.5% accuracy and let users tailor IC to specific voltage levels. Offered in 3 output configurations, IC also features adjustable timer to define duration of independently functioning UV/OV reset outputs.

Data Acquisition Module offers current monitoring.

Spectrum Control, Inc.
Fairview, PA 16415
Sep 13, 2006 Employing monitoring computer and 6 dual current sensing modules, Data Acquision Module 7832M-02 measures voltage and amount of current draw present at strategic points in system and verifies that system is operating within specified metrics. Data is transmitted via SNMP, but use of Telnet and serial communications is also supported. In addition to monitoring and reporting system aspects, module also helps identify circuit breaker trips and early stage device failures.

Current-Shunt Monitor suits power management applications.

Texas Instruments, Inc., Semiconductors
Dallas, TX 75243
Sep 08, 2006 Model INA206 combines high-side current-sense amplifier and 2 open-drain output comparators with internal 0.6 V voltage references in 14-pin package. Comparators provide over/under current detection or power supply over/under voltage detection. With gain setting of +20 V/V, unit features common-mode voltage range of -16 to 80 V, 500 kHz bandwidth, and supply range of 2.7-18 V, and is specified for ±3.5% maximum output error over -40 to +125°C temperature range.

Three-Phase Monitoring Relays protect machinery and people.

Three-Phase Monitoring Relays protect machinery and people.

Carlo GAVAZZI Automation Components
Buffalo Grove, IL 60089
Aug 25, 2006 Provided in 177-275 Vac and 323-550 Vac ranges, DIN rail mount Series DPB71 monitors for overvoltage, undervoltage, phase sequence, and phase loss situations on 3 phase and 3 phase+ neutral systems. Capable of monitoring 50-60 Hz, Series DPC01 is available in ranges from 115 Vac delta voltage through 690 Vac delta or star voltage. Units provide True RMS monitoring for over and under voltage, phase sequence, phase loss, and symmetry on 3 phase and 3 phase+ neutral systems.

Voltage Monitor features 4 different measurement inputs.

Voltage Monitor features 4 different measurement inputs.

Linear Technology Corp.
Milpitas, CA 95035-7417
Aug 01, 2006 LTC2914 voltage monitor IC contains undervoltage (UV) and overvoltage (OV) inputs and allows specific UV and OV trip threshold configuration with ±1.5% accuracy of monitored voltages. Buffered reference output and 3-state input polarity-select pin allow monitoring of 2 separate negative voltages. Featuring input glitch filters that eliminate noise and 70 µA quiescent current, IC is suited for telecom/network equipment, storage servers, and desktop and notebook computers.

Electronic Monitoring Relays measure current and voltage.

Electronic Monitoring Relays measure current and voltage.

Phoenix Contact
Harrisburg, PA 17111 0100
Jun 15, 2006 Measuring 22.5 mm wide, DIN-rail mount modules are suited for single- and 3-phase applications. Current monitoring relays handle AC and DC currents from 0-100 mA, 0-1 A, and 0-10 A, while voltage monitoring relays handle single-phase AC and DC voltages from 0-30, 0-60, and 0-500 V. Both types are available in 2 versions: single-function SL version and multifunctional FL version. Devices are configured via potentiometers and rotary switches on front face of modules.

Monitoring System ensures consistent weld quality.

Monitoring System ensures consistent weld quality.

Bosch Rexroth Corp., Electric Drives & Controls
Hoffman Estates, IL 60192
Feb 28, 2006 Offering current/voltage and/or ultrasonic control, Model PSQ 6000 provides non-destructive testing for medium-frequency applications in automotive welding and assembly lines. By measuring current and voltage, course of resistance and energy can be recorded, controlled, and evaluated during welding. Ultrasonic monitoring system consists of XQR control board, UDM signal processor, and ultrasonic sensors that ensure quality of spot welds during welding process.

Supervisory ICs have manual reset and watchdog functions.

austriamicrosystems AG
Premstatten   Austria
Jan 25, 2006 Suited for portable and battery-powered systems, AS1910-15 series dual-voltage microprocessor supervisory ICs consume 5.8 µA typ and feature manual reset input and watchdog function with timeout period of 1.5 sec. Products operate over -40 to +125°C range, generating reset when one of 2 monitored supply voltages falls below factory-trimmed thresholds of 1.8-3.6 V and 0.9-2.5 V. Design safeguards that ICs are in correct state for VCC down to 1.0 V.

Voltage Supervisors come in 2.95 x 2.8 mm SOT-23 package.

Voltage Supervisors come in 2.95 x 2.8 mm SOT-23 package.

Microchip Technology, Inc.
Chandler, AZ 85224 6199
Jan 19, 2006 Designed to monitor microprocessor activity in digital systems, MCP1316, MCP1316M, MCP1317, MCP1318, MCP1318M, MCP1319, MCP1319M, MCP1320, MCP1321, and MCP1322 integrate watchdog timer, manual reset, and multiple combinations of push-pull or open-drain reset outputs in 5-pin package. They operate over -40 to +125°C range at input voltages from 1.0-5.5 V, consume 5 µA typ, and feature factory trip-points from 2.0-4.7 V in 100 mV increments.

Voltage Monitoring ICs can be used as drop-in replacements.

Voltage Monitoring ICs can be used as drop-in replacements.

STMicroelectronics
Carrollton, TX 75006
Jan 06, 2006 Supplied in lead (Pb)-free, RoHS-compliant, SOT23-3L package, STM1061 series precision voltage detectors can be used for 1-bit A/D conversion, voltage limit monitoring, and microprocessor supervision. They are available with choice of 40 laser-trimmed voltage thresholds, offered in 0.1 V increments from 1.6-5.5 V, and typically consume 900 nA. Operating in -40 to +85°C temperatures, units can be used as MCU Reset ICs via external capacitor on open drain output.

Supervisory IC monitors UV or OV for power supplies.

Supervisory IC monitors UV or OV for power supplies.

Linear Technology Corp.
Milpitas, CA 95035-7417
Nov 29, 2005 Model LTC2909 features single select pin that chooses one of 3 polarity combinations for two 0.5 V adjustable inputs, which have threshold accuracy of ±1.5%. Product can monitor 2 supplies - positive, negative, or both - for undervoltage (UV), overvoltage (OV), or one of each. It can also monitor single supply, positive or negative, for UV and OV simultaneously. Other features include 6.5 V shunt regulator, adjustable reset timeout period, and power supply glitch immunity.

Current Alarm Module helps prevent motor failure.

Current Alarm Module helps prevent motor failure.

Automation Systems Interconnect Inc.
Mechanicsburg, PA 17055
Nov 29, 2005 Designed to detect potential problems before motor failure, CCIS current threshold alarm module monitors circuits rated from 1-30 A. Along with transistor and relay output capabilities, product features Hall Effect sensor that detects current level on line being monitored. A 24 Vdc signal is high when monitored current is below user-selected set point value and goes to 0 V in alarm mode. Threshold value can be regulated to detect dangerous currents.

Voltage Monitor alerts users to dangerous panel conditions.

Voltage Monitor alerts users to dangerous panel conditions.

Grace Engineered Products, Inc.
Davenport, IA 52807
Nov 10, 2005 Mounted inside control panel via DIN rail, VoltageVision(TM) Power Warning Alert locates every power source inside panel to maintain electrically safe work conditions. It enables those performing maintenance on open control panels to see voltage state of every power source. Hardwired into any power source, unit flashes whenever hazardous voltage is present in any single/3-phase or dc power system. System detects ac and dc voltage and operates from 40-750 Vac/30-1,000 Vdc.

Analysis System locates distribution impedance problems.

Analysis System locates distribution impedance problems.

Z Meters, Inc.
San Jose, CA 95124
Nov 09, 2005 Utilizing time-synchronized, multipoint measurement and correlation techniques, ZM100 characterizes impedance of distribution systems. It consists of 2 or more ZM100 Distribution Analyzers, connected to salient point in facility's electrical distribution system, used to identify and localize variety of conditions that can lead to voltage anomalies and/or power loss. Features include Bluetooth wireless communications and Windows-based software.

Motor Management System facilitates motor programming.

Motor Management System facilitates motor programming.

Siemens Energy & Automation, Inc.
Alpharetta, GA 30005
Oct 13, 2005 SIMOCODE pro replaces hardwired circuitry running to various motors across plant floor with one cable and one motor management tool, which provides protection, monitoring, and control functions for every motor feeder. Information such as motor current, motor direction, phase status, and overload status is visible on graphic display. Since SIMOCODE pro can execute its own logic internally, motor can be run locally if communication to PLC is disrupted.

Electrostatic Voltmeter features non-contact design.

Electrostatic Voltmeter features non-contact design.

Trek, Inc.
Medina, NY 14103 9710
May 17, 2005 Built to measure and monitor electrostatic charge, Model 400 incorporates vibrating reed probe sensor and noise null control potentiometer. It can be used with single chopper probe or dual chopper probe, which provides response time of less than 200 µsec for 1 kV step response with zero phase lag. There is no overshoot or undershoot when measuring step voltage changes, and measurement accuracy is better than ±0.05% of reading ±0.5 V at monitor output.

Current Sense Monitors offer wide common mode input range.

Current Sense Monitors offer wide common mode input range.

Texas Instruments, Inc., Semiconductors
Dallas, TX 75243
Apr 28, 2005 With common mode input of -16 to +80 V, Series InA19x measures high-side current in automotive, motor control, power management, and battery charging applications. Units feature single supply voltage of +2.7 to +18 V, with 400 kHz bandwidth, quiescent current of 700 µA max per channel, and temperature range of -40 to +125°C. Three output voltage transfer functions of 20, 50, and 100 V/V are offered.

Motor Management System offers expansion modules.

Motor Management System offers expansion modules.

Siemens AG
Munich D-80333  Germany
Apr 05, 2005 Simocode Pro V uses ground fault detection module to monitor motor feeders for possible ground fault. Up to 3 analog sensors can be connected to temperature module to check temperature of motor, gear oil, etc. Analog module supplements motor management system by analog inputs and outputs from 4-20 mA so level or flows can be monitored. Combined current/voltage recording module measures motor current as well as voltages up to 690 V, and monitors power-based variables.

Voltage Logger accommodates systems up to 600 Vac.

Voltage Logger accommodates systems up to 600 Vac.

Acksen Ltd
Belfast BT7 1NJ  United Kingdom
Nov 19, 2004 Three-Phase Electocorder, Model EC364-V monitors voltages in substations, distribution boards, and pumping stations. It measures minimum, average, and maximum voltages and stores data in memory with dates and times; Electrsoft software enables user to download data from logger, plot graphs, and save or export data. It also retains each Electrocorder’s location, installation date, and date on which logging is due to complete recording.