 Residual Gas Analyzers support Web-based reporting, control.MKS
Andover, MA 01810 2449
May 14, 2012
Quadrupole monitors HPQ3 and HPQ3S are PVD chamber sensors that do not require differential pumping. Able to detect single figure ppm air leaks during PVD process while simultaneously monitoring all gas species in mass range of 1-100 amu, analyzers feature ion source with dual filaments to ensure failure backup and continuous uninterrupted operation. Respectively, HPQ3 and HPQ3S provide data for processes up to total pressure of 1.3e-3 and 1e-2mbar.
|
DGA Monitoring System is designed to protect transformers.LumaSense Technologies, Inc.
Santa Clara, CA 95054
May 14, 2012
Used to enhance grid reliability, SmartDGA(TM) Guide helps electric utilities augment condition-based maintenance for transformer and load tap changer (LTC) fleets. System can monitor all 9 gases used in dissolved gas analysis (DGA) as well as moisture, and optional integration with LumaSMART fiber optics technology, which directly measures winding hot-spot temperatures within transformers, lets utilities monitor temperature and gas. Also, design reduces installation time to hours.
|
Dissolved Gas Monitor proactively diagnoses transformer failures.LumaSense Technologies, Inc.
Santa Clara, CA 95054
Apr 30, 2012
SmartDGA(TM) Guard continuously measures and reports multiple gases - hydrogen, acetylene, and CO - as well as moisture in transformers to help electric utilities improve grid reliability by diagnosing faults before they lead to serious incidents. With modular shape that enables installation within hours, online dissolved-gas analysis (DGA) monitor uses non-dispersive infrared (NDIR) gas sensing technology and is available with fully integrated communications for Smart Grid deployment.
|
Dissolved Gas Analysis Monitor suits load tap changers.LumaSense Technologies, Inc.
Santa Clara, CA 95054
Apr 02, 2012
Employing non-dispersive infrared technology, SmartDGA(TM) can help utilities achieve widespread condition monitoring across generation, transmission, and distribution assets, minimizing outages caused by faulty load tap changers and transformers. System uses proprietary algorithm, developed in accordance with utility standards, to analyze and report LTC conditions. SmartDGA requires no carrier gas, no frequent calibrations, and can be retrofitted to LTC's to provide asset condition status.
|
Purge and Barhole Tester is suited for confined spaces.RKI Instruments, Inc.
Union City, CA 94587
Mar 22, 2012
With IP66 protection, Model GX-2012 offers capabilities for datalogging as well as purge and barhole testing for pipeline companies and gas utilities. Unit can monitor standard confined space gases - LEL combustibles, O2 deficiency, CO, and H2S - as well as 100% volume Methane while dynamically displaying either percent LEL or percent volume with auto-ranging ability. Along with internal sample drawing pump, 5-sensor portable gas monitor features calibration and bump test reminders.
|
 Cross Stack Monitor utilizes tunable diode laser technology.Servomex Group Ltd
Crowborough East Su TN6 3DU United Kingdom
Nov 09, 2011
Able to detect wide range of gases, SERVOTOUGH LaserCompact 2900 delivers true continuous in-situ monitoring and is optimized for measurement across pipes and along short cells. Unit utilizes Tunable Diode Laser Spectroscopy technology to deliver response time of less than 2 seconds with minimal interference from background gases. Certified to ATEX and IECEx standards, LaserCompact is suitable for gas measurements in hot, dirty, or dangerous environments.
|
 CO/Nitrogen Dioxide Transmitters support in-field calibration.Dwyer Instruments, Inc.
Michigan City, IN 46361
Sep 19, 2011
Used to monitor gas concentration in underground parking garages and loading docks, Series GSTA offers field-selectable current and voltage outputs that allow transmitters to be used with almost any building management controller. User can select output range to be 0-200 or 0-500 ppm for carbon monoxide (CO) units, and nitrogen dioxide units come with 0-10 ppm range. Using internal dip switches, output can be inverted to read 20-24 mA or 10 (5) to 0 Vdc.
|
 Mobile Gas Monitoring Device uses wireless technology.Safety Supply South LLC
Irmo, SC 29063
Aug 22, 2011
Developed for use at industrial sites, Dräger X-zone 5000 is used in conjunction with Dräger X-am 5000 personal gas detection device to create wireless fence line alarm for toxic gases. Transportable device can be used individually or as part of continuous wireless network with up to 25 units for monitoring large areas, such as pipelines and storage tanks. Each unit continuously monitors up to 6 explosive, flammable, or toxic gases, and warns if one of them is present in ambient air.
|
 Process Gas Analysers com in cross-stack, extractive versions.Servomex Company, Inc.
Sugar Land, TX 77478
Jun 24, 2011
Featuring Tuneable Diode Laser (TDL) technology, SERVOTOUGH Laser series measures gases present in extreme or harsh process conditions. TDL technology minimizes response time and sample conditioning requirements while promoting stable performance without any moving parts or consumables. Series consists of Standard monitor for cross stack (in-situ) applications; compact variant for extractive and in-situ use; and MultiPass version for extractive trace analysis applications.
|
Online Transformer Monitor improves fleet reliability.BPL Global, Ltd
Cranberry Township, PA 16066
Mar 23, 2011
Serveron® Model TM1(TM) provides continuous dissolved gas analysis (DGA) monitoring of hydrogen gas in insulating oil along with alarm capability needed to maintain reliability of distribution transformers. Programmability allows alarm to be based on ppm levels and/or Rate of Change (ROC), warning operators of potentially disruptive transformer faults and pending failures. Optional moisture-in-oil and oil temperature measurements will also be available.
|
 Gas Sampling Monitor features internal pump and sensors.Enmet Corp.
Ann Arbor, MI 48106
Mar 08, 2011
With internal sample draw pump and gas sensors, microprocessor-based GSM-60 is designed for industrial process, aerospace, pharmaceutical, and semiconductor applications. It can be custom configured for monitoring combination of gas parameters, including VOCs, dew point, oxygen, and CO, or other target gases, such as O3, HF, HCl, Cl2, etc. Optionally, instrument may be connected to range of remote 4-20 mA toxic or combustible gas sensors/transmitters.
|
Gas Monitoring System serves environmental services market.Trimble Navigation Limited
Sunnyvale, CA 94085-3913
Dec 08, 2010
Designed for environmental consultants and landfill operations managers, SiteFID(TM) integrates positioning and mobile computing capabilities coupled with Flame Ionization Detection (FID) gas sensor technology. End-to-end solution helps streamline workflow for mobile workers as well as improve accuracy and compliance while on site. Field samples, recorded with GPS coordinates in real-time during field survey, may be transferred from handheld to back-office compliance applications.
|
Toxic/Flammable Gas Monitor suits low oxygen atmospheres.RAE Systems
San Jose, CA 95134
Oct 16, 2009
Packaged in weather-resistant, stainless steel housing, AreaRAE Inert features built-in pump with ability to monitor inert atmosphere using up to 100 ft of sample draw tubing, allowing unit to remain outside of work area and in radio contact with breathing air services and safety managers. Detector may be equipped with up to 5 sensors as application or worksite demands. Wireless range is up to 2 miles and data can be re-transmitted over Internet for remote monitoring and evaluation.
|
Handheld 4-Gas Monitor offers diverse functionality.RKI Instruments, Inc.
Union City, CA 94587
Sep 25, 2009
Weighing 4.6 oz, 2.75 x 2.95 .98 in. GX-2009 simultaneously monitors and displays combustibles, oxygen, carbon monoxide, and hydrogen sulfide. Its IP67-rated design, featuring impact-resistant rubber over-mold body resistant to RFI, incorporates dual audible alarm ports as well as alarm LEDs on 3 sides to increase condition awareness from multiple perspectives. Data logging system comes standard, and operation is accommodated via 2 glow-in-the dark, glove-friendly buttons.
|
 Chlorine Gas Sensor has extended calibration interval.Sierra Monitor Corp.
Milpitas, CA 95035 6825
Jul 23, 2009
Network-enabled smart gas sensor, 5100-06-IT, is standalone module with integral alarm relays and 6-month (180 day) calibration interval. Integration to existing plant-wide safety and monitoring systems is facilitated via 4-20 mA output, RS-485 Modbus interface, SentryBus interface, optional integral relay output, and digital display. Non-intrusive calibration, remote sensor option, and 316 SS enclosure options are also available.
|
Multi-Gas Monitor targets industrial and fire applications. Scott Safety
Monroe, NC 28111
Jun 18, 2009
Featuring 2-button interface, palm-size Protege Monitor detects oxygen, combustibles, hydrogen sulfide, and/or carbon monoxide. Data logging is based on event changes only, rather than automatic intervals, allowing for capture of relevant analytics while minimizing number of stored data points. Up to 7,000 events can be captured and stored for further analysis. To warn of high gas levels, unit uses bright visual, piercing audible, and vibrating tactile alarm indicators.
|
 Combustible Gas Detection System suits range of applications.General Monitors
Lake Forest, CA 92630
May 07, 2009
Offering scalable plant safety solution with voting, IR4000 Infrared Combustible Gas Detection System includes IR4000M Multi-Point Monitor that can connect up to 8 IR400 Point IR gas detectors and read their status with one command, one detector at a time. Versatile monitor incorporates display, relay module, and data concentrator in explosion-proof enclosure and magnetic interface. Certified by FM, CSA, ATEX, CE Marking, and IECEx, system is suited for use in SIL 2 environments.
|
Car Park System is compliant with German regulation VDI2053.Industrial Scientific Corp.
Oakdale, PA 15071 1500
Apr 21, 2009
Providing option of 4 or 8 relay output modules, CPS Car Park System is 8 channel digital controller designed to regulate and monitor ambient air in underground parking facilities and tunnels. It can be configured to monitor from 1-256 modules up to 3,000 ft away from controller with 6 smart transmitter options. Several sensor options including CO, NO, NO2, CH4, LPG, and H2 can monitor wide range of hazards emitted by gasoline, natural gas, diesel-powered, and electric vehicles.
|
Greenhouse Gas Analyzer takes simultaneous measurements.Picarro Inc.
Sunnyvale, CA 94085
Apr 03, 2009
Designed for continuous operation at altitudes up to 30,000 ft, G1301-m trace gas analyzer enables direct, in-flight, real-time sampling and analysis of CO2, CH4, and H2O in aircraft, ship, and similar environments. It is based on wavelength-scanned cavity ring down technology and withstands climb/descent rates to 1 km/min as well as associated vibration profiles. Sensor employs pressure and temperature stability and control technologies and does not require frequent re-calibration.
|
 Emissions Controller works with diesel/natural gas engines.CleanAIR Systems, Inc.
Santa Fe, NM 87502
Mar 09, 2009
E-POD(TM) combines non-toxic, zeolite-based selective catalytic reduction (SCR) catalyst, diesel particulate filters or diesel oxidation converters, and reductant mixing system within one, fully insulated, stainless steel, critical-grade silencer package. Installed above generator and becoming part of trailer's roof, system with DPFs enables Tier 4 final compliance for diesel stationary engines and NSPS compliance for lean-burn natural gas engines by reducing NOx, PM, HC, and CO.
|
(Showing headlines 1 - 20) more ....
|
Latest Products in the News |
Fireboy-Xintex - March 2, 2012 Xintex® Methane Gas Detector System
Concept Controls - September 26, 2011 Concept Controls Introduces New Family of Personal Gas Protection Devices: ToxiRAE
Honeywell Control Systems - July 13, 2011 Honeywell Helps Ithaca Energy Monitor Operational Performance of Key North Sea Oilfield
Honeywell Analytics - April 12, 2010 Honeywell Analytics Gas Monitoring Solution Offers Advanced Diagnostics to Reduce Safety Risk; Protects People, Processes and Profitability in Harsh Industrial Environments
RAE Systems - January 26, 2010 RAE Systems' Enhanced MeshGuard Wins at Large China Steel Mill
Emerson Process Management, Rosemount Div. - October 26, 2009 Emerson's Smart Wireless Technology Helps Calportland Company Comply with Air Quality Regulations at California Cement Plant
Huntingdon Fusion Techniques-USA Inc. - January 30, 2008 Piping Hot Start for Welding Company in 2008
RAE Systems - October 3, 2007 RAE Systems Delivers Custom Wireless Gas Detection Systems to PetroChina
RAE Systems - September 11, 2007 South Carolina Purchases GammaRAE II Radiation Detector and MultiRAE Plus Toxic Gas Monitors
RAE Systems - September 11, 2007 RAE Systems Wins Radiation Detector Order from South Carolina
More Products in the News...
|
|
|