Corrosion Monitors

Test & Measuring Instruments, Sensors, Monitors & Transducers, Services

Corrosion Testing is available globally via two laboratories.

October 20, 2014

Equipped with Q-FOG CRH cyclic corrosion tester, laboratories in Homestead, FL and Saarbrücken, Germany offer contract testing services for global customers for automotive corrosion tests requiring RH control. Available tests include GMW 14872 and SAE J2334 as well as others from Ford, ISO, GB/T, VW, Volvo, Chrysler, and Renault. Testers can also perform traditional salt spray and Prohesion® and meet international and automotive corrosion test standards. Read More

Test & Measuring Instruments, Sensors, Monitors & Transducers

Metals Testing System identifies wear and corrosion.

August 28, 2014

When placed on chemically treated test medium, one drop from Acustrip Metals Test® identifies presence and degree (ppm) of metals associated with wear and corrosion – copper, iron, and nickel – within 1 min.  Each metal has its own section on test medium, and regular use lets technicians and operators trend wear on engines and equipment component parts; abnormal presence of metals would lead to immediate corrective action. Product is designed for field use. Read More

Test & Measuring Instruments, Sensors, Monitors & Transducers

Cyclic Corrosion Testers include relative humidity control.

April 3, 2014

Available in both 600 and 1,100 L sizes, Q-FOG® CRH Testers can perform traditional salt spray and prohesion, and meet most major international and automotive corrosion test standards. Units feature RH control through use of air pre-conditioner. In addition to atomized mist salt fog, testers include optional shower function, where spray droplets are much bigger and flow rates are much higher. Advanced cleaning feature for spray nozzles prevents clogging frequently found in competitive chambers. Read More

Test & Measuring Instruments, Sensors, Monitors & Transducers

Downhole Coupon Holder provides metal loss measurements.

September 6, 2013

Withstanding temperatures to 302°F and pressures to 10,000 psi, DCHA (Downhole Coupon Holder Assembly) indicates general corrosion behavior patterns and acts as secondary metal loss measurement of downhole tubing when used in conjunction with DCMS Downhole Tool for corrosion monitoring. Solution holds up to 9 coupon holders, including Bent Beam, Strip, and Cylindrical corrosion coupons. Three types of coupon holders can be mixed and matched according to corrosion effects being evaluated. Read More

Test & Measuring Instruments, Sensors, Monitors & Transducers, Communication Systems & Equipment

Wireless Corrosion Transmitter works with water systems.

October 12, 2012

Measuring corrosion rate and pitting tendency, Corrater® CWT-9020 is designed for on-line monitoring of water systems in electrically hazardous areas with operating range of -40 to +70°C. Transmitter can be supplied as part of Cosasco® Wireless Corrosion Monitoring System or added to any Emerson Smart Wireless Network or output from gateway via Modbus Interface to any process automation system. Once installed, computed corrosion rate and pitting tendency may be read. Read More

Test & Measuring Instruments, Sensors, Monitors & Transducers

Corrosion Under Insulation Sensors are offered in 3 types.

June 15, 2012

Used to detect corrosion under insulation, Cosasco CUI sensors fit in with any plant integrity management program. Continuous Insulated Braid (corrosion fuse) Wire, Inserted corrosion fuse probe array, and CUI Corrosometer® Probe all offer direct corrosion detection and may be customized to meet individual requirements and applications. Facilitating installation, inserted corrosion fuse probe array and CUI Corrosometer® Probe do not require removal of insulation. Read More

Test & Measuring Instruments, Sensors, Monitors & Transducers

Corrosion Sensors detect corrosion underneath insulation.

May 31, 2012

Comprised of continuous insulated braid corrosion fuse wire (Type 1), inserted corrosion fuse probe array (Type 2), and CUI Corrosometer® probe (Type 3), Cosasco CUI Corrosion Sensors are used for detection of corrosion under insulation. Design facilitates installation and may be customized to meet individual requirements and applications. Types 2 and 3 do not require removal of insulation while still providing reliable detection. Read More

Test & Measuring Instruments, Sensors, Monitors & Transducers

Corrosion Sensors detect corrosion under insulation.

May 23, 2012

Offered in 3 types, CUI Corrosion Monitoring Sensors may be customized to meet requirements. Continuous Insulated Braid Wire Sensor, using insulated carbon steel wire as corrosion fuse, detects corrosion over large area. Inserted Probe Array Sensor acts as corrosion fuse detector that provides indication of corrosion occurring at pipe surface. Consisting of individual electrical resistance probe, CUI Corrosometer® Probe measures corrosion rate near pipe surface and helps determine underlying cause. Read More