|
|
|
|
Sensors Monitors & Transducers ->
Monitors
Monitors
(Showing headlines 601 - 620) << 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 ...
|
 Wireless Monitoring System helps monitor remote plant assets.GE Energy Rentals
Houston, TX 77029
Oct 22, 2008
Allowing operators to monitor inaccessible plant equipment, Essential Insight(TM) .mesh Wireless Condition Monitoring Solution enables temperature and vibration data to be transmitted wirelessly from asset to system software platform. With wireless sensors, system also helps enhance worker safety and ability to monitor equipment in hazardous areas. System comprises of wSIM(TM) sensor, Essential Insight .mesh repeater, Essential Insight .mesh manager gateway, and transducers.
|
 Assessment Kit fosters vibration energy harvesting adoption.Perpetuum Ltd.
Southampton United Kingdom
Oct 20, 2008
Wireless sensor node assessment kit, wSNAK, confirms advantages of condition monitoring systems powered by vibration energy-harvesting. Its 4 energy harvester-powered wireless sensor nodes send vibration/temperature data to laptop-based receiver, and each sensor node runs IEPE accelerometer with integrated temperature sensor on flying lead. Data is sent from each node, via IEE802.15.4 transmitter, to receiver situated up to 100 m away.
|
Monitor determines external pipeline corrosion rates.Rohrback Cosasco Systems
Santa Fe Springs, CA 90670
Oct 20, 2008
Using Soil Corrosion Rate Monitor, pipeline operators can quantitatively determine soil corrosivity for External Corrosion Direct Assessment pre-assessment process at time of pipe excavation or inspection. Unit consists of soil corrosion rate probe with replaceable cone shaped tip, and electrochemical Corrater® Aquamate LPR instrument, which includes Solution Resistance Compensation to extend range of soils in which measurements can be made.
|
Vibration Transducer incorporates side connector.SPM Instrument Inc.
Marlborough, CT 06447
Oct 15, 2008
Able to be used in harsh industrial environments where moisture/water poses constant challenge, SLD144S features side entry design that accommodates installation where space is limited. This compression type piezoelectric accelerometer, designed for vibration monitoring of industrial machinery, has nominal main axis sensitivity of 10 mV/m/s˛. Other characteristics include 10% max transverse sensitivity, 2 Hz to 10 kHz (±3 dB) linear frequency range, and 600 m/s˛ max peak acceleration.
|
 Power Quality Meter captures 10 MHz resolution transients.Electro Industries
Westbury, NY 11590
Oct 09, 2008
Designed for critical applications such as high voltage transmission and electrical distribution automation, Nexus® 1500 meter records energy usage and power quality from any metered point in power distribution network. It offers 1 GB storage memory, dual 100BaseT Ethernet communications, 256 color touch-screen user interface, USB support, and front mounted ANSI optical port. Other applications include data centers, hospitals, and wafer-fabs.
|
 Ultra-Mini PCs provide environmental monitoring.Graywolf Sensing Solutions
Shelton, CT 06484
Oct 07, 2008
Measuring 6.75 x 6 x 1.25 in., DirectSense® Ultra-Mini Vista OS PCs use USB-enabled multi-sensor probes to measure ppb range of VOCs, carbon dioxide, carbon monoxide, °C/°F, %RH, and additional specific gas for IAQ applications. Units include 40 GB hard drive, swiveling touch screen, keyboard, and built-in camera. Once measurements have been collected in field, users can review, analyze, and report on data and field-collected notes with included WolfSense® software.
|
Sensors detect corrosion in reinforced concrete structures.Roctest, Ltd.
Saint-Lambert, QC J4P2P4
Sep 29, 2008
Designed to detect and predict onset of steel corrosion in concrete, SensCore system consists of sensors, dataloggers, and measurement hub that concentrates data from several dataloggers and transmits it to central database. Sensors transmit their data wirelessly to measurement hub, eliminating need to install any wiring in the structure to be monitored. Modular system is adaptable to structures of all sizes, and can be installed in both new and existing structures.
|
UPS Battery Management System enables intelligent charging.Rittal Corporation
Springfield, OH 45504
Sep 26, 2008
Comprised of up to 250 RiBat modules joined using pre-assembled cable and connected to RiBat Manager, RiBat system extends UPS battery life up to 30% to promote IT system security and availability. RiBat Manager collects, evaluates, and uses all relevant data over service life of monitored battery to control charging process, while RiBat modules control charging process for each battery connected using technology that prevents overcharging.
|
Instrument enables condition monitoring at all skill levels.Schaeffler Group USA, Inc.
Fort Mill, SC 29715
Sep 26, 2008
Designed for early detection of damage in rotating machine elements, handheld FAG Detector III can be used to balance rotors and shafts in static and dynamic balancing applications. Firmware v3.4 provides 3D view of measurement data as well as waterfall diagrams, enabling display of results via 3D illustrations in Viewer. Offering database of more than 20,000 different bearing products from different suppliers, Trendline software enables user to analyze measurement data recorded using device.
|
Universal Gas Transmitter senses toxic and flammable gases.Honeywell International, Inc.
Morristown, NJ 07960
Sep 23, 2008
Utilizing catalytic bead, electrochemical, and IR technologies, Model XNX helps protect against toxic and combustible gases in petrochemical and industrial environments. Unit works with major industrial communication protocols, including Modbus, Foundation Fieldbus, and HART. Featuring stainless steel or aluminum enclosure with marine-grade coating, transmitter is IP66/67-rated with pending approvals to UL and CSA, and ATEX requirements for hazardous locations.
|
Portable PEC Test Instrument detects sub-surface corrosion.GE Sensing
Billerica, MA 01821
Sep 18, 2008
Featuring TFT color screen, 1 Gb memory, and 80 Gb hard disk, Pulsec uses pulsed eddy current (PEC) to deliver diagnostic imaging and depth resolution needed when inspecting multi-layer aircraft structures. Non-destructive tester has 6 hr battery life, weighs 13 lb, and is suited for inspecting difficult to reach places on aircraft. It can also detect cracks and offers on-board, real-time analysis and data recording/storage as well as export capabilities.
|
 GDI Sensors can measure pressures from 2,000-40,000 psi.Custom Sensors & Technologies (CST)
Moorpark, CA 93021
Sep 17, 2008
Utilizing thin film titanium oxynitride isolated sense element, Gasoline Direct Injection (GDI) sensors monitor and control fuel and air mixture in combustion chamber versus intake port. They have 17-4 stainless steel pressure diaphragm, operate on 5 Vdc, and provide 0.5-4.5 Vdc linear amplified analog output proportional to pressure. Suited for harsh, high-vibration environments, units have media operating temperature range of -40 to +180°C, and are impervious to EMI.
|
 Data Logging System records corrosion in pipelines.Pepperl + Fuchs, Inc.
Twinsburg, OH 44087 2245
Sep 12, 2008
Complementing CorrTran® MV online corrosion monitoring transmitter, Division 2/Zone 2 CorrTran® Corrosion Data Logging System allows users to access real-time corrosion data via Ethernet, USB, SD card, or locally via videographic chart recorder. System includes KFD2-HLC-EX1.D HART loop converter, which receives HART data from CorrTran MV corrosion monitor and delivers three 4-20 mA outputs that represent general corrosion, localized corrosion, and conductance.
|
Thermocouple Sensors cover power range of -35 to +20 dBm.Agilent Technologies, Inc.
Santa Clara, CA 95051
Sep 11, 2008
Suited for communications and aerospace and automotive electronics, N8480 Series thermocouple power sensors incorporate built-in EEPROM for storing calibration factors, which enables automatic loading of calibration factors. Models N8481A and N8482A feature frequency ranges of 10 MHz to 18 GHz and 100 kHz to 6 GHz, while Model N8485A has frequency range of 10 MHz to 26.5 GHz or 10 MHz to 33 GHz.
|
Portable Carbon Monoxide Monitor weighs less than 1 oz.KWJ Engineering Inc.
Newark, CA 94560
Sep 11, 2008
Able to run on replaceable watch battery, Pocket CO Model 300 nanotechnology-enabled instrument with digital readout protects from low-level and high-level exposure to CO, and gives time weighted average, maximum, and total exposure readings. Key-fob sized unit is suited for professionals and recreational users alike, including pilots, boaters, truckers, campers, building inspectors, firefighters, and first responders.
|
EFI Solutions increase embedded application reliability.Advantech Technologies, Inc.
Irvine, CA 92618
Sep 10, 2008
Embedded EFI BIOS offers flexible configuration that lets customers tailor their products to range of designs and target markets. With Embedded EFI Pre-Boot Application, Advantech System Configure Utility can automatically diagnose and detect CPU temp, fan speed, and voltage as well as send that information to remote EFI Alert Server for further action. Embedded EFI Alert Server provides real-time monitoring and alarm setting to remotely watch system status and log events.
|
Converters enable network analysis up to 325 GHz.Rohde & Schwarz GmbH & Co
Germany
Sep 10, 2008
Intended for 50-75 and 220-325 GHz ranges, Models R&S ZVA-Z325 and R&S ZVA-Z75 millimeter-wave converters connect directly to 4-port R&S ZVA series network analyzers, eliminating need for any extra hardware. Converters for V, W, and J bands can be operated as part of base unit, and exceed 90 dB at 75 GHz and 60 dB (typ. 80 dB) at 325 GHz, allowing even high-blocking filters to be analyzed. Adjustable output power facilitates tests on amplifiers in development stage.
|
 Precision Shunt Set directly measures current in laboratory.Fluke Corp.
Everett, WA 98203
Sep 09, 2008
Able to measure currents from 1 mA to 100 A, A40B Precision Current Shunt Set consists of 14 low-inductance coaxial current shunts, adapters, and connectors in rugged transit/storage case. Shunts provide absolute ac or dc current measurements as well as ac/dc current transfer measurements. Suited for precision current applications such as calibrator verification, units have high dc resistance stability and come with report of traceable calibration, including data.
|
 Temperature Profiling System monitors solar cell production.Datapaq Inc.
Wilmington, MA 01887
Sep 04, 2008
Created to monitor wafer temperature as it travels through furnace, Solar Cell temperature profiling system can be used for various thermal processes including contact firing/metallization, diffusion, PECVD, and lamination. It consists of data logger, thermal barrier, and analytical Insight(TM) software. Information such as peak temperature, time above temperature, slopes, and Delta T appear on results summary screen. Built in alarms alert when process is out of specification.
|
Network Monitor captures, stores, and replays network traffic.Endace Limited
Manukau City New Zealand
Sep 04, 2008
Able replay speeds reaching 10 Gbps, NinjaProbe allows network operators to replay events, enabling recreation of real network scenarios that help identify cause and effect of alarm conditions, load and test networking and security equipment, and actively study user experiences. It unobtrusively monitors every packet on network links, writes copy of each packet to system memory, and simultaneously adds time stamp with nano-second granularity. On-board storage expandd to 128 TB.
|
(Showing headlines 601 - 620) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79
|
|
|