 Solvent-Usage Monitor offers local and remote reporting.AW-Company
Franksville, WI 53126
Jun 21, 2004 Solvent Usage Monitoring System (SUM), provides central hub for recording and reporting total usage of up to 20 solvent flowmeters. Totals or rates can be viewed in GPM or LPM on integral, digital display or output to printer via serial port. Additionally, collected data may be viewed from remote location in HTML web-page format via TCP/IP Ethernet communication port. Data page displays totals from up to 20 flowmeters on one page. |
Resistivity System determines presence of oil and gas.GE Energy Rentals
Atlanta, GA 30339
Jun 21, 2004 Centerfire™ Resistivity System provides formation evaluation data while hole is being drilled. MWD probe mounted above resistivity collar facilitates retrieval and data transmission to surface. Tool combines multiple transmitter spacings and separate frequencies for accurate and stable readings, and is available in sizes with 4.75, 6.75, and 8.25 in. OD. System operates at temperatures to 175°C in water and oil-based drilling fluids, and in flow rates to 1,200 gpm. |
Transmitter provides environmental monitoring.Stevens Water Monitoring Systems, Inc.
Portland, OR 97220
Jun 11, 2004
Based on OCXO crystal, GOES-certified Model GHT uses ASCII programming format, allowing it to be programmed from any computer with terminal program using menu-driven commands. In addition to operating with Stevens and Vitel data collection platforms, transmitter operates as ASCII modem for use with 3rd party data loggers providing serial output. Applications include monitoring of streams and reservoirs, meteorological stations, tidal and port systems, and ground water.
|
 Flaw Detection System uses volumetric grid scanning.Uni-Tech Engineering
Pelham, AL 35124
Jun 08, 2004 Featuring UT probes, CCD video camera for V-Scan grid positioning, and industrial notebook PC with software, ShafTest® portable ultrasonic system provides repeatable in-situ testing of shafts and axles. Software highlights cracks and provides tools to plot ultrasonic cross-sections through shaft at any depth chosen by operator. System requires only shaft-end access, avoiding equipment disassembly or multiple setups and scans in confined situations. |
 Power Quality Recorder features 8 channels.Powertronics
Candia, NH 03034
Jun 04, 2004 Multi-channel PQR-OEM monitors and records quality of power being supplied to equipment and facility. It monitors 3 ac hot voltage channels from 90–480 Vac, 1 ac neutral channel from 0–50 Vac, and 4 channels of current from 20–5,000 ac A via current transducer. All disturbances are recorded with date, time, magnitude, and duration in non-volatile Flash Memory on repetitive 30-day cycle. Software can be used to download data from RS232 serial port or USB port. |
 Edge Detector automatically adjusts to new web widths.AccuWeb, Inc.
Madison, WI 53707
Jun 02, 2004 WideArray™ Edge Detector detects web edges passing through 18.4 in. wide edge detection range. When positioned on opposite sides of web in center guiding mode, detection range is doubled, providing 36.8 in. fully compensated detection. Wide detection range allows operators to change guide point or web width without manual adjustment. Detector is available in ultrasonic and infrared models. |
 Supervisor monitors up to 6 supplies.Linear Technology Corp.
Milpitas, CA 95035
May 28, 2004
Available in SOT-23 and DFN packages, LTC2908 hex supply monitor is suited for densely packed systems with multiple, low-voltage supply rails as well as 5 or 3.3 V logic supplies. Product holds reset low with as little as 500 mV of input supply voltage. With 1.5% threshold accuracy over -40 to + 85°C operating temperature range, unit ensures reliable reset operation without false triggering. It features 2 adjustable inputs with nominal threshold of 0.5 V and 4 fitted thresholds.
|
Infrared Thermocouples feature 4:1 field of view.Exergen Corp.
Watertown, MA 02472
May 27, 2004 Models microIRt/c.4-K-440F/220C and microIRt/c.4SV-K-440F/220C are self-powered, miniature thermocouples measuring 0.25 dia x 1.0 in. L and 0.50 dia x 1.0 in. L, respectively. Sensing range is -49 to +975°F and ambient temperature range is -40 to +212°F. With ambient temperature compensation circuit, units hold true accuracy with changes in ambient temperature. They are hermetically sealed, intrinsically safe, and have no active electronics. |
System manages end-to-end application performance.Network Physics
Mountain View,, CA 94043
May 26, 2004 Model NP-2000 incorporates Automatic Autonomous System Discovery (AASD), which enables users to monitor and troubleshoot IP service performance across Multi-Protocol Label Switch (MPLS) cloud. Product measures critical metrics such as usage and utilization, network performance, server performance, and client performance. Deployed at major data aggregation points to analyze real-time traffic flows, it allows IT teams to centralize monitoring. |
 Bump Test Station works with personal gas detectors.Biosystems Div., Bacou USA Safety Inc.
Middletown, CT 06457
May 24, 2004 Suited for ToxiPRO™ and ToxiLTD™ personal gas detectors, IQ Express bump test and calibration station automatically performs up to 8 critical tests in under 20 sec. Procedures include instrument identification; battery test; audible, visual, and vibration alarm tests; fresh air calibration; bump test; and record keeping. If bump test fails, unit automatically completes full calibration without intervention from user. Product connects via USB for PC control. |
 Monitor Keyboard Drawer features standard mouse.Acnodes Corporation
Walnut, CA 91789
May 21, 2004 Integrated Monitor Keyboard Drawer Model KD9171N allows for efficient rack use. Drawer slides out from rack and LCD flips up for display. When not in use, it can be slid back and stored. Features include: compact 1U design with heavy-duty steel construction, 17 in. TFT LCD display, slide rail drawer, on-screen display function, built-in PS/2 keyboard, and standard mouse. |
Toxic Gas/Radiation Monitors offer wireless video.RAE Systems
San Jose, CA 95134
May 19, 2004
AreaRAE hazardous environment monitors, which include AreaRAE, AreaRAE IAQ, and AreaRAE Gamma, incorporate 16 fps, full motion, color video to provide first responders with visual confirmation of toxic or radiation alarm. This aids in determining real and false alarms. Based on 1- to 5-sensor monitor equipped with wireless, RF modem, products can communicate and transmit information in real-time with base controller located up to 2 miles away.
|
 Vibration Indicator features alarm set points.IMI Sensors, Div. of PCB Piezotronics
Depew, NY 14043-2495
May 10, 2004
Operating from AC or DC power, Model 683A panel-mount digital vibration indicator provides excitation for ICP® accelerometers or 4-20 mA, loop-powered, vibration sensors. LED display provides scaling and menu-driven setup of up to 4 set points, each with individual status indicators and relay outputs. Adjustable time delay eliminates false alarm trips due to momentary vibration upsets.
|
 Monitor detects alarm conditions at remote sites.Omnitronix, Inc.
Seattle, WA 98109 5108
May 10, 2004 Multi-purpose, Model SL81 manages unmanned sites that house non-SNMP enabled equipment such as power sources, PBXs, batteries, telecom boxes, and serial alarms. Once alarm condition is detected, technician can connect to serial device to diagnose and correct problem. Up to 16 external sensor modules can be chained to unit to monitor remote equipment rooms and cabinets. User can view status by connecting to IP network through SL81 via dial-up networking Web Browser. |
Algorithm Analysis Package helps debug serial bus design.Agilent Technologies, Inc.
Santa Clara, CA 95051
May 07, 2004
Suited for use with oscilloscopes, E2688A serial data analysis package translates analog waveforms, consisting of hundreds of data points, into 2-digit 8B/10B symbol codes. It provides analysis techniques that help save time in debugging, characterizing, and validating high-speed serial bus designs. Software includes software clock recovery and real-time-eye mask testing features that help streamline cycle of acquiring, testing, and identifying failures.
|
 Warning Light System indicates heating system failure.Lumastrobe Warning Lights
Midland Park, NJ 07432
May 04, 2004 Independently powered Freeze Flash early warning signal indicates probable failure of heating system that could cause freezing pipes and water damage. Comprised of 5 LED lamps positioned within inner diffusing Fresnel lens with outer protective red dome, it utilizes 2 D-Cell batteries to provide 60 double flashes per min of bright red signal. Adjustable thermostat can be set from 35–60°F, and unit flashes for 400+ hr with alkaline batteries. |
 Coal Fire Detection System continuously monitors CO.AMETEK Solidstate Controls
Columbus, OH 43085
May 01, 2004
MILLWATCH continuous sampling system, which consists of probe and control unit, monitors CO in pulverizers and storage bins for fire and/or explosion protection. Product incorporates sampling and purging systems to maximize instrument performance. All electronics are contained on one PCB and are engineered to perform in harsh environments.
|
Hazardous Gas Monitor is designed for confined spaces.RAE Systems
San Jose, CA 95134
Apr 22, 2004
EntryRAE personal gas monitor incorporates photoionization detector to monitor combustible vapors, oxygen, carbon monoxide, and hydrogen sulfide gases while also providing broadband protection from toxic and chronic effects of industrial compounds. Unit detects VOCs at ppm concentrations, providing protection needed to ensure long-term health and safety of those who work in areas with limited ventilation.
|
Portable Gas Detector comes with integrated PID.Mine Safety Appliances Company / Instrument Division
Pittsburgh, PA 15230
Apr 21, 2004 Combining 2 instruments into one, Sirius Multigas Detector features PID in multigas unit. It enables users to monitor for hundreds of potentially dangerous vapors and chemicals. Equipped with alarm system that warns of hazardous situations, unit simultaneously monitors for VOCs and combustible, toxic, and oxygen-deficient atmospheres. Features include interchangeable lithium-ion and alkaline battery packs and long-term storage kit. |
 Gas Monitors utilize 0–10 ppm hydrogen fluoride sensor.MSA
Pittsburgh, PA 15230 0426
Apr 13, 2004 Ultima XE and XA provide continuous monitoring using electrochemical technology. Ultima XE features 316 stainless steel enclosure, while Ultima XA has all-purpose plastic enclosure with NEMA 4X rating. Both use interchangeable smart sensors, which when recognized, trigger automatic alarm and relay setting reconfiguration. Display alternates between sensor reading and gas type. Onboard LEDs and relays provide indication of alarm and fault conditions. |