Sensors Monitors & Transducers ->
Monitors
Monitors
(Showing headlines 1141 - 1160) << 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 ...
|
 Data Collector has intrinsically safe design.Rockwell Automation
Milwaukee, WI 53204
May 27, 2005
Suited for industries with ATEX Zone 0 Group II requirements, Entek Enpac Ex collects data and monitors condition from mechanical equipment operating in Class 1 Div. 1 environments. Windows CE-based, 2-channel data collectors and signal analyzers employ analog and digital electronics, including DSP and Sigma-Delta ADC, to help ensure safe condition monitoring of equipment found in process industries with rotating equipment.
|
 Weld Purge Monitor is self-calibrating.Huntingdon Fusion Techniques-USA Inc.
Melbourne, FL 32936-1175
May 26, 2005
Portable Argweld® Monitor measures oxygen levels down to 0.1% but will indicate down to 0.01%. Supplied with support equipment in protective carrying case, unit features temperature compensation and continuous or sample reading.
|
 Battery Integrity Monitor offers fully automatic operation.Adcour
Woburn, MA 01801
May 24, 2005 BIM1 checks battery every 15 min. to provide early warning of battery faults or failures. It measures voltage and impedance and produces signal if battery is ever removed from system. Available for systems from 12–120 V, models are offered for local or remote alarm indication. All models install with 2-wire connections and use software to automatically start setup process. |
 Monitor indicates when batteries need watering.Philadelphia Scientific
Montgomeryville, PA 18936
May 20, 2005 Blinky™ features bright green indicator light, compact top designed to fit small cells, and probe with notches to facilitate cutting to desired length. Safety fuse is located inside body for added security. Blinky includes grommet for installation and false indication circuitry, preventing false signal from being generated when battery actually needs water. |
 Strain Gage Layer provides 18-bit resolution.United Electronics Corp.
Rosemont, IL 60018
May 20, 2005
Designed for PowerDNA distributed I/O cube family, PowerDNA Model DNA-AI-208 Analog Input Strain Gage layer allows engineers to distribute and monitor strain gage measurements close to test source throughout PC-based Ethernet test environment. Unit provides internal excitation of sensors and has 8 isolated differential channels, max sampling rate of 1 kHz/channel, 2 wiring schemes, overvoltage protection, and software for onboard shunt calibration.
|
Detectors monitor health of industrial equipment. Honeywell Sensing and Control
Golden Valley, MN 55422
May 18, 2005
Series EHM Equipment Health Monitoring Systems are available in 10 models to monitor temperature loss, fluid flow, temperature rise, mechanical noise, fluid leak, mechanical wear, audible noise, vibration, tilt, and mechanical insertion. Units sound alarm when operating values drift from pre-defined settings. By alerting user of possible problems early, detectors may help prevent essential equipment from shutting down.
|
 Monitor eliminates downtime at remote equipment sites.Omnitronix, Inc.
Seattle, WA 98103
May 18, 2005 Suited for critical monitoring of remote cellular, microwave, and broadcast communications sites, alarm sensing device, Model SL-10 operates at -48 Vdc and outputs up to 9 Vdc at 1 A to power network components. With 6 contact closure inputs, 2 voltage inputs, 2 output relays, temperature sensor, and humidity sensor, unit can integrate variety of environmental conditions and legacy equipment into network monitoring system by providing alarm notification via SNMP traps. |
 Electrostatic Voltmeter features non-contact design.Trek, Inc.
Medina, NY 14103 9710
May 17, 2005 Built to measure and monitor electrostatic charge, Model 400 incorporates vibrating reed probe sensor and noise null control potentiometer. It can be used with single chopper probe or dual chopper probe, which provides response time of less than 200 µsec for 1 kV step response with zero phase lag. There is no overshoot or undershoot when measuring step voltage changes, and measurement accuracy is better than ±0.05% of reading ±0.5 V at monitor output. |
 Field Monitor offers local and remote operation.AR Worldwide
Souderton, PA 18964
May 12, 2005 Starmonitor model FM7004 automatically configures itself to work with StarProbe or battery-powered E or H field probes. Featuring displays and graphics that facilitate reading of unit, product can be locally or remotely operated from front panel controls or through provided IEEE 488.2, USB 2.0, or RS-232 interfaces. |
 Portable Flaw Detector is sealed to IP 66 standards.GE Inspection Technologies, GmbH
Huerth 50354 Germany
May 06, 2005 Protected against ingress of dust and strong jets of water, ultrasonic USM 35X is used for inspection tasks from flaw detection to corrosion measurement. Unit provides rotary knobs for setting gain and function values, and operator can select required dB step width, freeze displayed A-scan, or switch A-scan to full screen size by means of direct access keys. Software allows operation to meet Japanese weld inspection standard Z3060-2002.
|
Network Appliance is suited for medium-sized organizations.Network Physics
Mountain View,, CA 94043
May 06, 2005 NP-500 appliance provides troubleshooting across network environments rated for up to 20 Mbps throughput and can store 160 Gb of data in a RAID-1 configuration. Non-intrusive product delivers detailed, real-time and historical information pertaining to over 60 network metrics. With included NetSensory OS, users can organize network data into business groups and applications for automated aggregation, analysis, correlation, and alerting. |
Camera detects concealed weapons in real-time.Brijot Imaging Systems, Inc.
Orlando, FL 32819
May 06, 2005 With 45 ft range, BIS-WDS™ Prime uses passive millimeter wave sensor technology to detect guns, knives, or bombs of metal, plastic, or composite construction. Weapons Detection System (WDS) consists of millimeter wave camera combined with video camera and algorithm software that interfaces to other security devices/networks. Capable of identifying up to 50 threats simultaneously, system produces electronic alarm when suspicious item is detected. |
 Electronic Counter keeps track of applicator usage.TE Connectivity Ltd.
Berwyn, PA 19312
May 05, 2005
Integrated into AMP applicators, EDGE Counter displays cycles since installation to track tool usage and optimize maintenance scheduling. On-counter LCD display and EDGE Counter Software Pack provide access to operation counts and other applicator statistics. Tool enables operators to perform applicator maintenance and tool replacement at measured intervals with pre-set limits. Counter and software use wireless IR technology to transfer data.
|
 CO2 Transmitter works in HVAC applications.E+E Elektronik GmbH
Engerwitzdorf A-4209 Austria
May 05, 2005 Suited for measuring CO2 in ventilation channels, EE85 features closed loop air stream and diaphragm that protect CO2 sensing cell from pollution. CO2 detection is based on non-dispersive infrared technology (NDIR), and aging effects are compensated by auto-calibration procedure. Available for measuring ranges of 0–2,000 ppm and 0–5,000 ppm, transmitter has compact design that facilitates installation. |
 Smart Radar Device measures level of solids.Endress + Hauser Inc.
Greenwood, IN 46143
May 04, 2005 Able to withstand harsh process conditions, Micropilot M FMR250 non-contact level gauge is protected against dust, vapors, and product temperatures up to 392°F. Loop-powered, 2-wire device has max measuring range of 230 ft. Available with narrow beam parabolic antenna or 3 in. horn antenna, unit is set up via menu on local display or by connecting to PC with HART® modem. Device is designed to measure level of plastic pellets, corn, soy beans, cement, and fly ash. |
 IC Test Clips are sized for use in electronics.Cal Test Electronics
Yorba Linda, CA 92887-4604
May 04, 2005 General-purpose MiniPro™ series test clips, suited for circuit and basic test interconnections, feature smooth, soft touch actuation and gold-plated beryllium copper hooks. Offered in 10 colors, series features secure, snap-lock assembly that withstands heavy use. EU- and RoHS-compliant products are available individually, with lead wires, or in 10-piece kit. |
 Hour Meter features wireless operation.Shockwatch
Dallas, TX 75247
May 04, 2005
To assist with scheduling maintenance based on actual operating hours, Shockswitch® RF Hourmeter measures running hours of various types of equipment by monitoring up to 3 independent inputs such as keyswitch, drive motor, and hydraulic motor. Runtime information is transmitted via 802.11/b/g wireless network to either local or remote computer running Java-based companion software. Device is also equipped with LED operating status indicators.
|
Proxy Server connects local network to Internet.eSafeLine
Novosibirsk Russian Federation
Apr 29, 2005 GateWall v3.0 proxy server Internet-management tool is designed to connect local network users to Internet. Application provides centralized control over Internet connections, bandwidth, and time online, while automating daily routines such as calculation of consumed traffic, client reporting, and billing. It can restrict Internet access based on user's time online, traffic limits, IP addresses, URL strings, or specified traffic speed limits.
|
 Current Sense Monitors offer wide common mode input range.Texas Instruments, Inc., Semiconductors
Dallas, TX 75243
Apr 28, 2005 With common mode input of -16 to +80 V, Series InA19x measures high-side current in automotive, motor control, power management, and battery charging applications. Units feature single supply voltage of +2.7 to +18 V, with 400 kHz bandwidth, quiescent current of 700 µA max per channel, and temperature range of -40 to +125°C. Three output voltage transfer functions of 20, 50, and 100 V/V are offered. |
 Thermocouple Input Device offers 8 bits of digital I/O.Measurement Computing Corp.
Norton, MA 02766
Apr 27, 2005
USB-based Model USB-TC provides 8 temperature inputs, 500 V isolation, and built-in ambient temperature sensing. Unit supports all common thermocouples and performs all linearization and cold-junction compensation. Internal measurement electronics accuracy exceeds temperature sensor accuracy, minimizing system error. Device includes TracerDAQ stripchart recorder/data logger software as well as SoftWIRE graphical programming interface for Visual Studio .NET.
|
(Showing headlines 1141 - 1160) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79
|
|
|