 Digital Room Temperature Transmitters offer 2-wire operation.Devar, Inc.
Bridgeport, CT 06605
Feb 22, 2011
Featuring 0.4 in. high, 7-segment, red, LED display, Models d-RTT and d-RTTI can sense ambient room temperature across operating range of -40 to 180°F with display resolution of 0.1 degrees. Units have operating voltage range from 10-28 Vdc and provide 4-20 mA output signal, linear to measured temperature to within ±0.1°F. High precision 1,000 W RTD sensor, attached to backside of black anodized aluminum heat sink visible on front of instrument, conforms to DIN Standard EN 60751, Class A.
|
 Touch Screen Vision Sensors offer Ethernet connectivity.Banner Engineering Corp.
Minneapolis, MN 55441
Feb 22, 2011
iVu Plus can store up to 30 inspections, while Sort sensor function facilitates sorting of as many as 10 patterns in single inspection. Featuring 3 discrete communication channels over Ethernet or serial interfaces, both integrated touch screen TG and BCR (bar code reader) models can transmit data, such as inspection and image results, to HMIs and PCs. A 2.7 in. LCD color built-in display comes standard on integrated models, while remote versions feature 3.5 in. display.
|
Wireless Sensor Tags monitor environmental temperature, RH.Ekahau, West Coast
Saratoga, CA 95070
Feb 22, 2011
Respectively, tags TS1 and TS2 feature 1 and 2 extended cable probes that can be installed inside environment where temperature is being measured and have -328 to +302°F range. HS1 tag measures RH up to 100% and temperature ranges from -40 to +185°F. While battery power lasts up to 3 years at 15 min reporting interval, tags can sample temperature/humidity as often as 15 sec or as required. On-board heuristics enable immediate reporting of anomalies that occur between reporting intervals.
|
Ultrasonic Level Transmitters can measure volume and flow.Emerson Process Management
Austin, TX 78754
Feb 22, 2011
Rosemount® 3107 and 3108 work with Rosemount 3490 Series universal controllers to provide combined measurement and control of level, volume, or open channel flow (using flumes or weirs) in industrial and water utilities applications. Along with 12 m measurement range, both 24 V loop-powered devices offer 4-20 mA and HART communications. Transmitters come in factory-sealed, IP68-rated UPVC housing, and Rosemount 3108 also features remote temperature probe.
|
USB Power Sensor provides peak and pulse waveform measurements.Giga-tronics, Inc.
San Ramon, CA 94583
Feb 22, 2011
With frequency range of 100 MHz to 20 GHz, Model GT-8555A provides fully calibrated, peak and average RF and microwave power measurements, making it suited for wireless communications and defense electronics systems. Unit supports power versus time, time gating, and automatic pulse parameter measurements. Delivering 2,000 readings/sec, sensor has wide dynamic range of -40 to +20 dBm and low VSWR of 1.2:1. It includes PC-based user interface and MeasurementXpress software.
|
CMOS Image Sensor targets smartphone market.OmniVision Technologies, Inc.
Sunnyvale, CA 94089
Feb 22, 2011
Based on 1.4 micron OmniBSI pixel architecture, 3 megapixel Model OV3660 supports 720p HD video recording at 30 fps with cropping and scaling, as well as 4:3 image capture for snapshots. Backside illumination sensor offers automatic image control functions including exposure control, white balance, auto 50/60 Hz flicker detection, and black-level calibration. Featuring 1/5 in. optical format, sensor can be directly inserted into industry-standard 6.5 x 6.5 mm module.
|
Image Sensor uses backside illumination technology.OmniVision Technologies, Inc.
Sunnyvale, CA 94089
Feb 22, 2011
Based on OmniBSI-2(TM) pixel architecture, 8 megapixel Model OV8830 supports 1080p or 720p HD video recording. Unit's 2 x 2 binning functionality with post-binning re-sampling filter minimizes spatial artifacts and removes image artifacts around edges, while integrated scaler enables electronic image stabilization while maintaining full field of view in 1080p/30 HD video mode. Designed to fit into industry standard module size of 8.5 x 8.5 x 6 mm, sensor targets smartphone market.
|
Live Encoder enhances large-scale multi-screen services.Envivio, Inc.
South San Francisco, CA 94080
Feb 18, 2011
Intended for Mobile TV, Internet TV, and IPTV services, 4Caster(TM) C4 Gen III can ingest sources and deliver up to 15 outputs per channel. Live encoder/transcoder can deliver traditional broadcast television services and TV to other platforms from single platform and single headend. In addition to Intel® Xeon® Processor 5600 Series and Envivio multi-core compression engine, solution leverages capabilities of v2.4 firmware, which provides support for Envivio Genesis(TM) output format.
|
Intrinsically Safe Density Meter targets flammable fluid market.Integrated Sensing Systems
Ypsilanti, MI 48198
Feb 18, 2011
Featuring UL, cUL, and ATEX certification, FuelSense(TM) provides density range of 0.6-1.3 g/cc with ±0.001 g/cc accuracy and temperature range of 5-60°C. By adding meter to existing volumetric flow meters, mass flow can be tracked in critical custody transfer operations. IP67/NEMA 4X-rated meter is also suitable for hydrogen and methane applications for density and concentration of gas mixtures. With remote data logging option, 2 GB of data can be logged and stored internally.
|
 Pressure and Temperature Transducers suit subsea systems.Paine Electronics, LLC
East Wenatchee, WA 98802
Feb 17, 2011
Designed to meet API 17F/ISO 13626-6 and CIA 443 requirements, Digital SubSea CANopen® Series provides intelligent CANopen® networking solution for pressure/temperature measurement. Series measures pressure from 0-10,000 psia with better than 0.04 psi resolution and temperature from +20 to +150°F with 0.5°F resolution. Constructed of all-welded titanium, transducers include micro Subconn® MCBH4F subsea connector. Alternate pressure ranges and port fittings are available to meet requirements.
|
 Safety Interlock Switch delivers Category 4 safety protection.Omron Scientific Technologies Inc.
Fremont, CA 94555
Feb 17, 2011
Offering ISO 13849-1 (Safety Category 4/PLe) compliance for use higher-risk applications, non-contact D40Z measures 48 x 25 mm and has operating distance of 15 mm. Up to 15 switches may be combined with programmable G9SP Safety Controller for use in high-risk, multi-door access applications, and as many as 30 units can be connected to one G9SX-NS Controller. Additional features of this IP67-rated switch include non-magnetic actuator and 2-color diagnostic LED display.
|
 Level and Flow Monitor uses non-contact ultrasonic sensor.Greyline Instruments, Inc.
Massena, NY 13662
Feb 17, 2011
Equipped with 3-key calibration system, Model SLT 5.0 can be used as level transmitter for tank inventory applications with continuous display and control, or as open channel flow monitor with display and totalizer. Unit includes non-contacting PVC and Teflon® sensor rated for ranges up to 32 ft. Housed in NEMA 4X enclosure, monitor provides isolated 4-20 mA output and has 3 control relays programmable for pump control, pump alternation, level alarms, and/or flow proportionate pulse.
|
Acceleration Sensor enhances electric vehicle safety.Continental AG
Auburn Hills, MI 48326
Feb 17, 2011
Intended for electric and plug-in hybrid vehicles, evSAT sensor employs algorithm to detect frontal, rear, or side collision. Accident information is passed onto battery management system, which then shuts off high-voltage battery to eliminate risk of electric shock faced by emergency service personnel responding to accident victims. Comprised of independent triaxial sensor with CAN interface, sensor enables battery shut-off within 0.5 sec of accident of 4 sec max during rollover.
|
 Calibration Verification System aids flare flow measurement.Fluid Components International
San Marcos, CA 92069
Feb 16, 2011
Allowing technicians to confirm flow measurement accuracy for gas and flare flow meters within minutes, VeriCal(TM) in-situ system is designed for applications aboard offshore platforms as well as land-based oil/gas and chemical plants. Verification of flow meter calibration is performed without removing meter from pipe or process. System combines air/gas flow element with additional electronics that feed and measure precise flow of gas from nitrogen source.
|
 Absolute X-ray Photodiodes target solar spectrum studies.Opto Diode Corp.
Newbury Park, CA 91320
Feb 16, 2011
Featuring 10 x 10 mm active area, IRD AXUV 100GX Absolute X-ray Photodiode possesses known active silicon thicknesses and 100% internal quantum efficiency, allowing absolute measurement of X-ray flux with energies of 100 keV and beyond. Unit requires no external voltage for operation, operates at room temperature, and provides up to 1 Gigarad of radiation hardness. Photodiodes with directly-deposited, thin-metallic filters are available for reducing response to visible light.
|
Pressure/Temperature Transducer operates in remote locations.Paine Electronics, LLC
East Wenatchee, WA 98802
Feb 16, 2011
Operating in temperatures from -40 to +260°F, 220-10-020 Series digital pressure and temperature combination transducer is offered in pressure ranges from 0-100 to 0-10,000 psis and provides temperature measurement from -40 to +300°F. Accuracy of digital pressure output is 0.075% FS, with resolution of 16 bits, while temperature resolution is 10 bits minimum and better than 0.5°F. Product requires input current of 25 mA at 5 Vdc, and includes RS485 interface for digital output.
|
 Torque Flanges are available with optimized shaft coupling.HBM, Inc.
Marlborough, MA 01752 3014
Feb 15, 2011
Series T40 torque flanges are available with sturdy ROBA-DS shaft coupling to securely and accurately record torque. Shaft coupling, which compensates for any existing radial, axial, or angle offset that may arise when torque flange is installed, is characterized by high torsional stiffness and low mass moment of inertia. As ROBA-DS shaft coupling is ideal match for HBM torque flange, users can be sure torque is correctly applied in torque flange.
|
 Capacitive Proximity Switch offers 150 nm p-p resolution.Lion Precision Inc.
St. Paul, MN 55126 7014
Feb 14, 2011
Offering 15 kHz (-3 dB) bandwidth, CPA100 Capacitive Sensor has setpoint (switched) output to indicate presence/absence, but nonlinear analog output is capable of resolutions as low as 15 nm RMS. Other features include panel range indicator and user adjustments for Offset (Zero) and Gain. Probe selection enables measurement from 0.05-6 mm, and offset/gain can be controlled with remote potentiometers. Also, sync connectors allow interference-free use of multiple sensors with same target.
|
 Programmable Encoders offer 60 arcsec positioning accuracy.Baumer Ltd.
Southington, CT 06489 1534
Feb 14, 2011
Available in IP67 version, HS35 Hollow Shaft Incremental Encoders withstand shocks up to 200 g, high-pressure cleaning, and ambient temperatures from -40 to +212°F. Units are available in programmable square wave, square wave, and sine wave versions for shaft diameters from 0.5-1.0 in., and can be further customized via shaft insert adapters, which provide electrical isolation against voltages up to 2.5 kV. Resolution is PC-programmable from 1-8,192 ppr in increments of 1.
|
 Strain Sensors measure strain on curved mounting surfaces.Columbia Research Labs., Inc.
Woodlyn, PA 19094
Feb 11, 2011
Customized to measure circumferential strain around diameter of surface to which it is mounted, Series DT3747 is self-temperature compensating and offers choice of cylindrical mounting radius. Specified mounting radius is custom molded into body, providing method of controlling operator alignment during sensor mounting. Applications include aircraft structural fabrication, pipe expansion measurements, explosive body applications, and engine monitoring.
|
(Showing headlines 701 - 720) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362
|
|
|