Sensors, Monitors & Transducers
(Showing headlines 6381 - 6400) << 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 ...
|
 Capacitive Sensors are immune to noise.TURCK, Inc.
Plymouth, MN 55441
Jan 10, 2003 Series BCF AC Sensors utilize fixed oscillator frequency combined with rectifier filter for noise immunity and exceed most specifications listed by CE. Oscillator allows sensor to maintain constant frequency, regardless of sensitivity adjustment. Fixed frequency is high enough to ignore most standard noise levels seen on plant floors. Sensors have 30 mm plastic housing. DC models are also available. |
 Opacity Monitor automatically corrects for dirt accumulation.Ducon Technologies, Inc.
Farmingdale, NY 11735
Jan 10, 2003 Model KVB measures opacity or dust concentration in stack gases. Vibration-resistant unit uses laser light source, which provides wavelength stability and 100% beam collimation. Opacity monitor, with weatherproof housing weighs, less than 40 lbs and has 1 mm beam dia. It includes on-line zero calibration feature, and does not require factory calibration. MIP opacity monitor has data acquisition system designed around instrument. |
 Pressure Transducers offer ranges from 5-1,000 psi.Druck, Inc.
New Fairfield, CT 06812
Jan 10, 2003 Series DPS 4000 features digital CANbus serial communications interface. Fully temperature corrected pressure readings are output as digital word at up to 100 Hz in any one of 24 engineering units, requiring no user system set-up or calibration. Integral digital electronics provide 0.2% reading for values above 50% FS and 0.1% FS for readings below 50% FS. Transducers are fully input/output isolated and suitable for automotive test stands. |
 Gauge helps meet NOx emissions regulations.Mid-West Instrument
Sterling Heights, MI 48314
Jan 10, 2003 Model 130-PC indicates flow of ammonia-air mixture in selective catalytic reduction systems. It also monitors ammonia filter prior to injection into vaporizer. Applications include simple cycle gas turbine facilities, combined gas turbine/steam turbine facilities, and conventional fossil fuel fired plants. |
 Input Modules monitor temperature sensor signals.Acromag, Inc.
Wixom, MI 48393 7037
Jan 09, 2003 BusWorks® 965PB Input Modules interface thermocouple and millivolt signals directly to ProfiBus-DP network. With up to 6 channels of input, modules support operation on 12–36 Vdc power supplies and support communication rates up to 12M baud. Features include user-selectable ranges for sensors and signals, sigma-delta 16-bit A/D converters, built-in CJC sensors, and thermocouple break detection. Three-way 1500 Vac isolation protects against surges and ground loops. |
 Rotary Transmitters work with thermocouples and strain gages.Magtrol, Inc.
Buffalo, NY 14224
Jan 09, 2003 Products transmit electrical measurement signals from rotating part to stationary measurement system or PC and do not contain slip rings. Offered with choice of 4, 8, or 12 channels, they operate up to 40,000 rpm. Features include resistance of less than 0.2 milliohms, noise of less than 25 mV, and signals up to 0.5 A/cell, 60 V AC/DC. Units are suited for use in aerospace, machinery, paper, and automobile industries. |
 Seal-Leak Detector prevents fires and toxic emissions.Bently Nevada Corp.
Minden, NV 89423
Jan 09, 2003 Through online monitoring and trending of critical seals, Seal-Leak Detection (SLD) system detects failures on process pumps in refineries and chemical plants. It directly measures pressure across seal’s face, allowing operators to detect pressure changes indicative of failing seals. SLD system is part of Trendmaster® PRO distributed condition monitoring system, which provides real-time mechanical condition dashboard for industrial equipment assets. |
 Encoder enables multiple line-count capability.PITTMAN
Harleysville, PA 19438 0003
Jan 09, 2003 Reflective Optical Sensing 35 mm Encoder for brush-commutated and brushless DC motors, features PC board-based modular design and multi-tracked code discs to enable resolutions from 192–512 counts/revolution. Incremental, non-contacting rotary-to-digital feedback device translates real-time shaft angle, speed, and direction of rotation to TTL-compatible outputs. Outputs are 2-channel, in quadrature, with medium resolution encoding. |
 Pressure/Temperature Switches suit hazardous locations.United Electric Controls
Watertown, MA 02472
Jan 08, 2003 Explosion-proof 120 Series switches provide dual-conduit wiring and cover lock. Wetted materials and pressure port configurations are available for pressure ranges from vacuum to 6,000 psi. Differential pressure models start at pressures of 0.2 in. WCD and extend to 500 psid. Temperature switches offer remote bulb and capillary sensing or local immersion stem and cover ranges from -180 to +650°F. Single/dual outputs provide threshold detector. |
 Pulsed Discharge Detector offers plug-and-play operation.Valco Instrument Co., Inc.
Houston, TX 77255
Jan 08, 2003
Model D3-1-HP helium ionization detector, with Valco Helium Purifier, is specified for HP 6890 gas chromatograph. It includes helium purifier and is suitable for use with columns from 50 micron capillaries to 1/8 in. packed. Universal detector is non-radioactive and non-destructive. With no open flame, no hydrogen requirement and close-to-true-mass response, unit can upgrade FIDs in petrochemical environments.
|
 Transducer suits high-vacuum applications.HPS Div., MKS Instruments Inc.
Boulder, CO 80301
Jan 08, 2003 HPS® Series 909 Mini Ion Transducer integrates hot cathode sensor and electronics control package. Bayard-Alpert type transducer measures vacuum from l0-10 to 10-2 Torr. Electron bombardment degas function is pressure controlled, automatically stopping and restarting at preset pressures. Each unit has 2 yttria-coated iridium filaments and screen to shield grid and filaments from large particles. RS485 digital communications are standard. |
 Gas Monitors utilize electrochemical sensing technology.Industrial Scientific Corp.
Oakdale, PA 15071 1500
Jan 08, 2003 AirAware™ fixed point gas monitors detect ammonia, carbon monoxide, chlorine, hydrogen sulfide, oxygen, nitrogen dioxide, or sulfur dioxide. They are equipped with 4-digit LED display, dual intensity high/low visual alarms, push-button operation, and non-instrusive calibration. Ammonia version includes digital ModBus® RTU signal output and user-customizable selections such as alarm set-points, text/numeric display and span gas values. |
 Gas Alarm detects H2S or CO.BW Technologies
Calgary T2A7X9 Canada
Jan 08, 2003
GasAlert100 provides 100 days of continuous, maintenance-free protection from H2S or CO. It offers 2 alarm levels and alphanumeric LCD. Intrinsically safe unit provides solution to plant turnarounds and short-term work projects. It measures 1.00 x 1.45 x 2.30 in. and weighs 1 oz.
|
 Thermocouple Transmitters feature cold junction compensation.JH Technology, Inc.
Sarasota, FL 34233 2432
Jan 03, 2003 Thermocouple Transmitters, available in DIN rail, plug-in, and 2-wire models, have compensators potted directly into terminal to minimize errors under varying ambient conditions. They include low-drift input circuitry, AC and DC power choices, and Quick-Check output LEDs. Plug-in HI/LO temperature alarms are available. |
 Miniature Sensors offer 1.0 m sensing range.Banner Engineering Corp.
Minneapolis, MN 55441
Jan 03, 2003
Series VS4 Opposed-Mode self-contained sensors utilize optically correct lens, which redirects visible red sensing beam 90° off internal circuit board, sending light out narrow side of sensor. Designed for presence sensing inside machinery, 10-30 Vdc sensors have max output rating of 50 mA. Constructed of thermoplastic with polycarbonate mounting holes and lenses, sensors include noise suppression and meet IEC IP67 and NEMA 6 standards.
|
 Contrast Sensor detects labels.Carlo GAVAZZI Automation Components
Buffalo Grove, IL 60089
Jan 03, 2003 For use with fiber-optic cables, PD60CNK contrast sensor is suitable for packaging and labeling equipment. Sensing distance is set via programming pad on back of sensor. Available with 10–30 Vdc supply voltage, sensor has NPN/PNP outputs that can be configured as NO or NC. |
 Photoelectric Sensor detects transparent objects.Carlo GAVAZZI Automation Components
Buffalo Grove, IL 60089
Jan 03, 2003 Microprocessor-based, polarized PD60CNG detects transparent and highly reflective objects such as glass and plastic bottles. Single optical axis provides precise measurement of objects. Applications include packaging, bottling, and pharmaceutical equipment. Pushbuttons, on back of sensor, for teach-mode programming, allow sensing distance, timing, and NO/NC adjustments. Sensor is available with 10–30 Vdc supply and NPN/PNP outputs. |
 Color Sensor offers up to 4 outputs.Carlo GAVAZZI Automation Components
Buffalo Grove, IL 60089
Jan 03, 2003 Series PD12 has sensing distance of 2–60 mm, depending on type of fiber used. User places object in front of sensor and pushes Teach button. Sensor automatically sets itself to detect only that color. Each output has built-in timer function to prevent false outputs at color boundaries. Sensor, with NPN/PNP outputs, can be configured for normally open or normally closed operation. |
 Overfill Detectors are compatible with existing systems.Dixon Valve & Coupling Co.
Chestertown, MD 21620 1135
Jan 03, 2003 Flotech fuel tanker overfill detection system incorporates API-compatible 2 and 5 wire optic probes with double elastomer design to seal and secure optic prism tip. Complete system includes sensors, probes, sockets, and on-board monitors. Test kits are available for thermistor and optic systems. All components are drop-in compatible for installation in other API overfill systems.
|
 Pressure Switch offers 4–20 mA output signal.Dresser Instrument Headquarters, Ashcroft Pressure & Temperature Instrument Operation
Stratford, CT 06614 5145
Jan 02, 2003 N-Series electronic indicating pressure switch provides pressure indication and switch functions. Users observe values on ˝ in. LED display and can toggle between process pressure, setpoint, and reset point. Unit utilizes K Series thin film pressure sensor and circuit board housed in NEMA 4X/IP 66 rated, epoxy-coated, aluminum enclosure. Setpoints with adjustable deadband are available for alarm, shutdown, and control applications to 20,000 psi. |
(Showing headlines 6381 - 6400) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362
|
|
|