|
|
|
|
|
Sensors, Monitors & Transducers
(Showing headlines 581 - 600) << 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 ...
|
Air Velocity Transmitter features built-in relay.Omega Engineering, Inc.
Stamford, CT 06907
May 11, 2011
Featuring hot wire air velocity sensor design and choice of fixed mount or remote probe configurations, Model FMA900A measures air velocity up to 12,000 fpm with 2% full scale accuracy. Unit provides response time of 250 msec, 0-5 Vdc or 4-20 mA analog output, and 1 SPST relay contact closure with red LED indication. Equipped with adjustable high alarm set point, transmitter is suited for development labs, HVAC, and exhaust/ventilation hoods.
|
Liquid Ultrasonic Flow Meter integrates self diagnostics.Emerson Process Management
Austin, TX 78754
May 10, 2011
Daniel(TM) 3812 Liquid Ultrasonic Flow Meter features accuracy of ±0.3% and repeatability of ±0.1%. It utilizes 2 mid-radius, parallel-plane measurement paths to reduce influence of flow disturbances, and includes 4 non-wetted, intrinsically safe transducers to maintain high accuracy over varying flow conditions. Predictive diagnostics package provides view of meter health and status, and Ethernet compatibility lets multiple users remotely monitor and verify process information.
|
DTV Monitoring System fully supports DVB-T2 networks.Rohde & Schwarz Canada, Inc.
Ottawa, ON K2V1C7
May 09, 2011
R/S DVMS lets network operators monitor DVB-T2 transmitter and signal feed via T2 modulator interface without any additional equipment. Also, solution supports monitoring of single-frequency networks (SFN) and RF spectrum (shoulder). Support for electrical as well as optical feeding for IP interface allows use independent of feed circuits available in network, and DVB-T options for shoulder and SFN measurements are available for DVB-T2 as well.
|
 Phased Array Flaw Detector features 10.4 in. touchscreen.Olympus
Waltham, MA 02453
May 06, 2011
With optimized data storage capacity and transfer rate, OmniScan MX2 provides inspection capabilities for manual and automated phased array applications. Integral 10.4 in. LCD touchscreen facilitates navigation, text input, and parameter setup, while SD card and USB interfaces provide connectivity. Fully compatible with phased array modules already in field, modular instrument comes with all software options, including multigroup, time-of-flight diffraction, and weld overlay wizard.
|
Waveform Building Software accelerates, facilitates engineering.Agilent Technologies, Inc.
Santa Clara, CA 95051
May 06, 2011
Compatible with various waveform generators, BenchLink Waveform Builder Pro enables R/D engineers to create custom waveforms using equation editor and waveform math and drawing tools. Features include standard function library, waveform sequencer, and signal filtering and windowing functions for signal modification/refinement. Signal's frequency characteristics can be viewed using FFT capability, and complementary cumulative distribution function curves show signal's power characteristics.
|
Wireless Sensor System measures pressure behind well casing.Emerson Process Management
Pleasanton, CA 94566
May 06, 2011
Designed to measure pressure and temperature behind casing in subsea production wells online and in real-time, Roxar Downhole Wireless PT Sensor System - Annulus B consists of Integrated Downhole Network system, Downhole Network Controller Card, wireless reader, wireless PT Transponder and antennae, and transponder and reader carrier. System is qualified to last minimum of 20 years at temperatures up to 302°F and pressures up to 10,000 psi, with accuracy of ±2.5 psi and ±0.18°F.
|
 Coating Thickness Gauges measure all metal substrates.Paul N. Gardner Co., Inc.
Pompano Beach, FL 33060 6608
May 05, 2011
Ready to measure with no calibration adjustment required for most applications, POSITECTOR 6000 III Series includes versions for ferrous metals, non-ferrous metals, or for all metal substrates. Standard models feature monochrome display and can store 250 readings, while advanced models, with reversible color LCD, store 100,000 readings and enable data transfer via USB to PC or via Bluetooth to PC or printer. Scan mode lets users take continuous readings without lifting probe.
|
 Process Imaging System monitors cement kilns continuously.Raytek Corporation
Santa Cruz, CA 95061 1820
May 05, 2011
Model CS210 process imaging system enables cement manufacturers to continuously monitor rotary kilns to detect hot spots due to refractory loss, damage, and wear. Providing temperature monitoring along entire length of kiln shell, IR system also detects abnormal conditions such as faulty flame position and shape. Unit includes MP150 HR linescanner, with 1024 data points/scan line, as well as Ethernet TCP/IP communications and Windows® 7 compatible DataTemp® CS Software.
|
Spectrodensitometers monitor industrial press production.Konica Minolta Sensing Americas, Inc.
Ramsey, NJ 07446
May 04, 2011
Handheld spectrodensitometers are available in FD-5 series models that measure density and color, as well as FD-7 series units that can also monitor paper, inks, and plant lighting conditions. Models in FD-7 series offer scanning mode for creation of ICC profiles, and can measure over 400 times/sec. Able to account for fluorescence of paper substrate, both products also allow users to provide measurements that comply with Flexographic Image Reproduction Specifications and Tolerances.
|
SpCO Sensors non-invasively detect CO poisoning.Masimo, Inc.
Irvine, CA 92614
May 04, 2011
Available in handheld and bedside devices, rainbow® Reusable Direct Connect SpCO Sensors are suited for patients with low oxygen saturation of 90-95% and elevated methemoglobin between 0-2%. Units continuously measure total hemoglobin, oxygen content, carboxyhemoglobin, methemoglobin, Pleth Variability Index, and acoustic respiration rate. By allowing immediate and non-invasive assessment of toxic CO levels, sensors enable early detection of CO poisoning to facilitate life-saving treatment.
|
 USB Ribbon Microphone combines vintage sound, modern technology.Marshall Electronics
El Segundo, CA 90245
May 03, 2011
Suited for those requiring retro sound during digital recording, UR-1 microphone combines classic, mellow sound of ribbon microphone and integrates it with USB technology. Electrical circuitry matches input requirements of ADCs and USB output with low-noise and high dynamic range. Focused in all-metal body with double-shielded grill, microphone can be used for recording singing, voiceovers, and podcasts. Volume control and headphone jack allow real-time monitoring without any latency.
|
Mechanical Encoders offer 10, 15, and 20 PPR resolutions.CUI, Inc.
Beaverton, OR 97005
May 02, 2011
Housed in 9 mm package, 2-bit quadrature ACZ09 Series features rotational life of 30,000 cycles, operating temperature range of -10 to +65°C, and insulation resistance of 300 Vdc, 100 MW. Incremental encoders can be configured in over 1,000 different versions and are suitable for audio, aircraft, medical, and test equipment applications.
|
Digital Photosensors integrate with occupancy sensors.WattStopper
Santa Clara, CA 95050
May 02, 2011
Designed to detect only visible portion of lighting spectrum, single-zone closed loop Model LMLS-400 and multi-zone open loop Model LMLS-500 include 2-way IR transceiver for communication with wireless configuration tool. Model LMLS-400 additionally features automatic commissioning for either switching or dimming. Either sensor can be configured for on/off switching, bi-level or tri-level step switching or step dimming, or continuous dimming for each controlled zone.
|
 Hand Force Measuring System helps assess occupational safety.Kistler Instrument Corp.
Amherst, NY 14228 2119
Apr 29, 2011
Type 9809A hand force measuring system is designed for short- and long-term assessments of biomechanical forces, loads, or applied stresses to objects or machines. System features 2 hand force measuring handles with charge amplifiers, as well as USB interface, datalogger with CompactFlash card, DAQ system, software, and cables. Included multi-component piezoelectric force transducer offers dynamic measurements in 3 orthogonal directions. Unit requires laptop PC with USB port for operation.
|
True Absolute Encoder offers FANUC serial communications.Renishaw, Inc.
Hoffman Estates, IL 60192
Apr 29, 2011
RESOLUTE(TM) is available with FANUC serial communications in linear encoder formats, offering sub-micron accuracy and resolutions to 1 nm. Suited for precision machine tool builders requiring max performance from linear axes, product promotes smooth velocity ripple and servo stiffness while reducing hysteresis errors. It determines absolute position immediately upon switch-on, and images are captured, analyzed, and interpolated to resolutions as fine as 1 nm at speeds to 100 m/sec.
|
 Circuit Breaker Power Monitor/Meter promotes system reliability.Eaton Corporation
Raleigh, NC 27615
Apr 28, 2011
Engineered for OEMs, PM3 module monitors power of branch and main circuit applications. It specifically measures current and voltage, calculates power and energy usage, and provides breaker status. Designed for Series G L-Frame and Series C K-Frame molded-case circuit breakers, this UL-Listed, add-on communications device can also be installed in reverse-feed applications with reverse-fed breakers. Measurement accuracy is within 2% of reading.
|
 Ammonia Gas Sensor utilizes smart sensor technology.Sierra Monitor Corp.
Milpitas, CA 95035 6825
Apr 28, 2011
Offered with cast aluminum or 316 stainless steel enclosure for hazardous areas, Model 5100-25-IT is network-enabled with choice of outputs, including 4-20 mA, serial RS-485 Modbus RTU interface, or optional 8 A integral relays. Unit features 8-character, fixed and scrolling LED display and extended calibration frequencies that only require calibration every 6 months. To meet unique application requirements, remote sensor configuration option is available.
|
 Toroidal Sensor is housed in NEMA 4X enclosure.Sensorex
Garden Grove, CA 92841
Apr 28, 2011
When combined with TCSMA or TCSTX toroidal transmitter, TCS3020 toroidal sensor offers complete conductivity measurement system. Sensor is designed for 0-1,000 mS performance and provides non-contacting, inductive type conductivity measurement. Resistant to corrosion, coating, and fouling, product is suited for long-term deployment without any maintenance. Construction is of Noryl, operation is rated up to 150 psig, and solvent tolerance and temperature stability are rated to 105°C.
|
 Thermal Remediation Verification Kit remotely monitors sterilization.CAS DataLoggers, Inc
Chesterland, OH 44026
Apr 27, 2011
Suitable for thermal sterilization work up to 175°F, including bedbug extermination, Thermal Remediation Verification Kit proves temperature was reached and maintained above critical point to guarantee eradication. Kit includes 6 wireless temperature data loggers and 10 ft probe to monitor temperature in narrow spaces such as between mattresses and inside walls. Three loggers have internal temperature sensors ranging from -40 to 80°C, and 3 feature external sensors measuring -60 to 155°C.
|
 Photoelectric Sensors are offered in 18 mm rectangular models.AutomationDirect.com
Cumming, GA 30040-9905
Apr 27, 2011
Photoelectric sensors in GX series are available in rectangular plastic DC models, which are IP67-rated and have 18 mm dia threaded lens and M12 quick-disconnect. GX3 series diffuse photoelectric sensors feature fixed sensing distances of 100 or 150 mm, while GXP series polarized reflective photoelectric sensors have sensing distances of up to 20 m. Through-beam photoelectric models of GXR/E series feature sensing distances of up to 4 m.
|
(Showing headlines 581 - 600) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362
|
|
|