Sensors, Monitors & Transducers
(Showing headlines 4601 - 4620) << 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 ...
|
 Contractor Gages possess psi scales with 1% FS accuracy.Dwyer Instruments, Inc.
Michigan City, IN 46361
Nov 16, 2006
Featuring stainless steel housings and brass wetted parts, 4.5 in. Series CONG withstands temperatures of -40 to 160°F. Wide offering of ranges is available from full vacuum, compound to 500 psi. Units are suitable for wholesalers, since each gage is delivered in plastic clamshell package that can be stocked on shelf.
|
 Difference Sensors are unaffected by target deviation.Baumer Ltd.
Southington, CT 06489 1534
Nov 16, 2006
Suited for use in static and dynamic applications, OBDM 12 laser sensors detect targets that match pre-programmed differential value within operating range of 16-120 mm regardless of any uncontrolled wobbling, movement, or elevation changes. Data output feeds directly to PLC, and response time is 1 ms. Teachable sensors come in 5 versions for step sensing, min/max analysis, tolerance analysis, window analysis, and comparing in automated production environments.
|
 Sensor offers absolute position output up to ±1,440°.BI Technologies Corp.
Fullerton, CA 92835-1051
Nov 16, 2006
Developed for automotive steering applications, digital angular position sensor offers analog, PWM, and CAN Bus outputs. With ±0.40% accuracy and 0.1° resolution, device features 12-bit resolution over 360° of rotation and life cycle of 25 million rotations, minimum, and operates at 5 V and between -40 to 125°C. Device also can be integrated with Magnetorque sensing technology for shaft applications.
|
Software System provides life safety event management.Keltron Corp.
Waltham, MA 02154
Nov 16, 2006
Through Windows-based alarm management system, Model LS 7000 delivers alarm monitoring, response, and dispatch services. Version 3.0 offers Programmable Event Segregation, which enables events to be directed to different operators at different workstations. It supports Ethernet transceiver, which transmits signals using 10/100 Mbps Ethernet communications. When system encounters problems with connections to event receivers, it reports, logs, and records information as supervisory alarms.
|
Automated Workstation detects helium leaks.Alcatel Vacuum Products, Inc.
Hingham, MA 02043
Nov 16, 2006
Designed to test small components in production environment, Model ASM 1002 features pumping package that evacuates test chamber and allows unit to quickly perform leak tests. At end of test, system displays Pass/Fail response to operator. With sealed package leak test software, system can achieve 1.10-9 mbar l/s leak testing in less than 4 sec. For testing open packages, software will keep unit in test mode as long as needed to allow operator to perform test.
|
Non-Contact Transmitter suits SIS applications.Westlock Controls Corp.
Saddle Brook, NJ 07662
Nov 16, 2006
Offering alternative to positioners for Safety Instrumented System (SIS) applications, D-EPIC Control Transmitter features integrated solenoid to control and monitor discrete valves as well as PST functionality. It senses valve position without linkages, levers, or rotary and linear seals. This 4-20 mA, HART-enabled transmitter, suitable for SIL3 service, eliminates position blind spots during valve stroke by supplying continuous feedback of either rotary or linear valve position.
|
 Analog Proximity Sensors provide sensing range up to 25 mm.Eaton Corp., Cutler-Hammer Group
Moon Township, PA 15108
Nov 15, 2006
Able to sense ferrous and non-ferrous metals, AccuProx(TM) Sensors output electrical signal that varies proportionately to position of metal target within sensing range. Available with both current and voltage outputs on same unit, sensors come in shielded and unshielded models in 12, 18, and 30 mm tubular barrels with variety of connection options. Applications include error-proofing, material blemish detection, absolute angle detection, and part positioning.
|
 Flow Switch minimizes pump maintenance.Fluid Components Intl.
San Marcos, CA 92069 5115
Nov 15, 2006
FlexSwitch® Flow/Level/Temperature (FLT) Pump Protection Flow Switch helps prevent overheating caused by sudden, unexpected reductions in media flow rates. Capable of monitoring substances such as liquids, gases, and slurries, solid-state product offers dual alarm capability for low-flow (0.01-3 fps) and dry running conditions. Dual-function instrument, specified in insertion or in-line styles, features two 6 A relay outputs assignable to flow, level, or temperature.
|
 Rotary Encoders suit space restricted applications.Pepperl + Fuchs, Inc.
Twinsburg, OH 44087 2245
Nov 15, 2006
With 40 mm outer diameter, IP54-protected Series TVI40N provides pulse outputs up to 1,024 ppr, and includes tangential cable outlet that ensures buckle-free connection. Utilizing Opto-ASIC technology, incremental rotary encoders operate from 4.75-30 Vdc with short-circuit proof, push-pull output, or 5 Vdc with RS-422 functionality. Loadable metal disk enables encoders to accept heavy loads without compromising performance.
|
 Hybrid Linear Actuators include encoder feedback.Haydon Switch & Instrument, Inc.
Waterbury, CT 06705 3910
Nov 14, 2006
Delivering thrusts up to 25 lb, Size 11 Actuators are available in resolutions from 0.000125-0.002 in./step. Optical incremental encoder incorporates lensed LED light source and monolithic photodetector array with signal shaping electronics to produce 2 channel bounceless TTL outputs. Operating from -40 to +100°C, encoder offers resolutions from 200-1,024 cycles/rev or 800-4,096 pulses/rev. Actuators are suited for applications requiring precise positioning and rapid motion.
|
 Pressure Gauges are color coded for safety identification.Dwyer Instruments, Inc.
Michigan City, IN 46361
Nov 14, 2006
Designed for identifying various pressure applications, Series CC features polyutylene terephthalate housings in red, blue, yellow, and green. Red and yellow cases identify safety conditions, while blue and green gauges identify specific process media. Offering 1% ANSI/ASME B40.1 Grade 1A accuracy, gauges are available with various pressure ranges for applications such as pumps, compressors, hydraulic presses and machinery, pipelines, and oil refineries.
|
 Utility Gauges have 3.5 in. faces.Dwyer Instruments, Inc.
Michigan City, IN 46361
Nov 14, 2006
Designed with black steel housings and chrome bezels, 3.5 in. Series UGD features dual psi and bar (100 x kPa) scales with 3-2-3% ANSI B40.1 Grade B accuracy. Wetted parts include brass socket and phosphor bronze Bourdon tube. Able to withstand temperatures from -50 to +160°F, gauges are offered with ranges from full vacuum, compound to 5,000 psi. Each unit comes with male ¼ in. NPT bottom connection.
|
Adjustable Pressure Switch suits OEM applications.Dwyer Instruments, Inc.
Michigan City, IN 46361
Nov 14, 2006
Comprised of 5 models, Series MHS Miniature High Sensitivity Pressure Switch features field-adjustable pressure set point options from 3-1,664 in. wc. All models use 1/8 in. NPT port and have mechanical life of over 10 million cycles. Used with air or compatible fluids, series offers electrical ratings from 3-15 A @ 125/250 Vac. Products can be used for controlling pumps and compressors by turning motors on and off as pressure changes.
|
 Fiber Optic Sensors feature programmable, NPN/PNP outputs.Automation Systems Interconnect Inc.
Mechanicsburg, PA 17055
Nov 14, 2006
With supply voltage of 10-30 Vdc and sensing distance of 10-200 mm, AF fiber optic sensors feature sensitivity adjustment along with keyboard to ensure that adjustments cannot be changed. Connection to sensors is made using standard sensor cables equipped with M8 connectors. Compact units can be din-rail mounted and are suited for detecting small parts, sensing marks and contrasts on packages, and presence control on automated equipment.
|
Linear Position Sensor suits wet environment applications.MTS Systems Corp. - Sensor Div.
Cary, NC 27513
Nov 14, 2006
With 3 discrete wires that allow sealing against wire insulation, C-Series Core Sensor operates using 5 V power supply and provides 0-5 Vdc or PWM output. Modular architecture enables addition of second electronics board for sensor operation at 12 V and provides additional protection circuitry for EMI immunity. Product is used in liquid or vapor laden environments such as small cutting, fastening, and forming tools, medical devices, and various outdoor-use products.
|
 Fluorescence Detector suits UHPLC applications.JASCO, Inc.
Easton, MD 21601
Nov 13, 2006
Incorporating advanced optics, holographic concave diffraction gratings, and non-spherical mirrors, Model XLC-3020FP is intended for ultra high pressure liquid chromatography applications. It is capable of data acquisitions at frequencies up to 50 data points/sec to allow for proper detection and integration of narrow peaks associated with UHPLC. Low dispersion micro flow cell provides optimal peak symmetry by eliminating band-broadening effects.
|
 Laser Scanner suits hazardous area applications.SICK, Inc.
Minneapolis, MN 55438
Nov 13, 2006
Targeted for applications in manufacturing and warehouse distribution environments where area to be monitored is less than 2 m, Model S300 Safety Laser Scanner provides oncoming fork detection on AGVs while also safeguarding workers in path of manned fork lifts and transfer cars. Compact device features 270° scanning angle that helps eliminate gaps in area being safeguarded and offers selectable resolution of 30, 40, 50, and 70 mm.
|
Dual Channel Counter suits industrial process monitoring.Laurel Electronics, Inc.
Costa Mesa, CA 92626
Nov 13, 2006
Designed for pulse rates from 0.05 Hz-1 MHz, UL-rated Laureate Model FRR counter can add, subtract, divide, and multiply 2 independently scalable pulse or AC input channels. Universal dual-channel signal conditioner accepts magnetic signals from 12 mV-250 Vac as well as signals from proximity switches with PNP or NPN output, TTL or CMOS logic, and contact closures. Built-in isolated 5, 10, or 24 Vdc excitation supply for powering proximity switches and other sensors is included.
|
 Radiation Detector acquires and stores spectroscopic data.Berkeley Nucleonics Corp.
San Rafael, CA 94901
Nov 13, 2006
Model 1703GNB Spectral-Gathering Personal Radiation Detector enables wireless transmission of critical spectral data files from product to any Windows® mobile compatible PDA. This stand-off detection functionality promotes personnel safety at incident scene by allowing user to place device at area of interest and move off to monitor safely. Network of 1703GNBs can be monitored from remote location by management personnel, allowing timely response to developing events.
|
Solid-State Viscosity Sensor suits low shear applications.SenGenuity, a division of Vectron International
Hudson, NH 03051
Nov 10, 2006
Designed to measure samples of low- to mid-range viscosity fluids, ViSmart(TM) provides continuous, real-time viscosity measurements for in-line process control systems. Measuring 1.3 x 1.1 x 0.4 in., acoustic sensor uses semiconductor technology, has no moving parts, and is sealed so it can be completely immersed in process stream. Sensor simultaneously measures fluid viscosity from 1-500 cp and temperatures to 125°C, with no field calibration.
|
(Showing headlines 4601 - 4620) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393
|
|
|