Accelerometer operates up to +150°C.Measurement Specialties, Inc.
Hampton, VA 23666
Aug 14, 2008
Available in ±10g to ±500g ranges, Model EGPE-1A provides flat frequency response up to 15 kHz. IEPE type accelerometer is hermetically sealed and features through hole mount installation for use with standard mounting screws. With micro-g resolution, unit is suited for broad range of vibration measurements.
|
Photo-IC Sensor optimizes display visibility.Toshiba America Electronic Components (TAEC)
Irvine, CA 92618-1811
Aug 14, 2008
Incorporating photodiode, current amplifier, and luminous-efficiency correction, Model TPS859 can turn keypad or LCD backlight on or off, or adjust brightness according to ambient light condition. Unit features typical light current of 230 µA, and optical filtering technology, which enables incandescent to fluorescent light sensitivity ratio of 1.0. Housed in 1.6 x 1.6 x 0.55 mm surface mount package, TPS859 operates from 1.8-5.5 V, making it suited for battery-powered applications.
|
Digital Monitor protects against environmental events.Microteknix
Pottstown, PA 19465
Aug 14, 2008
Designed to monitor and protect against temperature, humidity, and dewpoint events, Model EPC-2374 records sequentially formatted history and event logs by time and date. Unit allows for 3 independent contact outputs, each configurable for single event, or multiple logically configured events. Additional features include configurable audible alarm, ability to connect external phone dialer, and logic engine that supports up to 4 nested levels of user-created logic.
|
Machine Safeguarding Units monitor speed of rotating parts.Omron Corp.
Kyoto 600-8530 Japan
Aug 14, 2008
Designed to monitor back electromotive force of machine's motor to judge whether machine has stopped operating, Model G9SX-SM includes off-delay timer that is set to unlock Guard Lock Safety Door Switch after operation has stopped. Model G9SX-LM, using proximity sensor to monitor standstill and speed conditions, allows machine to operate with door of protective fence open only when rotational speed of hazard source is below pre-set threshold and operator is pressing enabling grip switch.
|
 Occupancy Sensor increases fluorescent fixture efficiencies.Hubbell Inc. (Delaware) / Wiring Device-Kellems Division
Milford, CT 06460
Aug 13, 2008
Designed for high mounting applications, HBA WASP(TM) Fluorescent High Bay Occupancy Sensor promotes energy conservation by using passive infrared (PIR) technology for occupancy detection. PIR lens provides 1.4:1 coverage up to 40 ft and is available with single or dual outputs. While single output sensor features primary timer for ON/OFF control, dual output sensor features 2 timers for multiple light level control (step dimming) as well as Smart Cycling(TM) technology.
|
 Radiologger transmits temperature and humidity readings.Hanwell Instruments Ltd.
Centerbrook, CT 06409
Aug 13, 2008
Enabling wireless monitoring, rl4106 temperature and humidity transmitter features real-time alarm notification and allows historical analysis of data. Unit includes onboard temperature sensor and humidity sensor, which can be mounted internally to transmitter body, externally on case, or remotely on probe. Powered by 3.6 V AA Li-Ion battery, it includes LCD screen that simultaneously displays recent readings and predicted battery life.
|
 Air Flow Sensor comes with integrated dual color display.Panasonic Electric Works Corporation of America
New Providence, NJ 07974
Aug 13, 2008
Available in 3 port sizes with total of 8 flow rate ranges of 0.5-1,000 Lpm, FM-200 Series is bi-directional digital flow sensor for use with air or Nitrogen gas that offers high precision detection of 3% F.S. Unit utilizes 2 temperature sensors, one on each side of a heater element, to determine heat distribution, providing accurate detection, regardless of flow direction. It has ability to display real time flow rate of any process and can function as a flow meter.
|
Tire Pressure Kit combines function of 2 tools into 1.Danaher Tool Group
Hanover, MD 21076
Aug 13, 2008
Designed to help with TPMS sensor maintenance during tire and rim changes, GearWrench® Tire Pressure Monitoring System Kit features sliding adjustable torque scale for setting and audible alert that indicates when predetermined torque value has been reached. Quarter inch flexible drive for screwdriver or torque wrench can accommodate up to 120 lb of air pressure. Kit also includes valve stem tool and 2 commonly used sockets for TPMS sensor maintenance.
|
Smoke Detector uses crystal-controlled wireless technology.NAPCO Security Group
Amityville, NY 11701
Aug 13, 2008
Enabling precision detection of even minute particles produced by clean-burning fires, GEM-SMK can detect all types of fires including paper, wood, gasoline, polystyrene, and smoldering fires. Photoelectric smoke detector eliminates need for home and business owners to run wires throughout their properties. It includes batteries with 5 yr life, mounting kit, and built in LED status indicator that alerts users when their battery is low or device is in need of cleaning.
|
Battery Monitoring System has wireless architecture.Midtronics, Inc.
Willowbrook, IL 60521
Aug 13, 2008
Suited for UPS environments, Cellguard Battery Monitoring System utilizes advanced wireless intra-system communications architecture that facilitates installation. System features wireless communications technology, and web and server-based data management.
|
 Pressure Transducer features digitally compenated design.American Sensor Technologies, Inc.
Mt. Olive, NJ 07828
Aug 12, 2008
Constructed of one-piece stainless steel, CE approved Model AST20HA contains no internal O-rings and is equipped with 100 V/m of EMI/RFI protection from electrical noise. ASIC design features real-time thermal compensation and linearity correction. Operating from -40 to 185°F, AST20HA provides pressure ranges from 0-25 psi to 0-10,000 psi and is available in compound ranges up to 2,500 psi. Output options include 4-20 mA, 1-5 V, 1-10 V, and 0.5-4.5 V ratiometric.
|
 Position Sensors offer output range of 0.5-4.5 Vdc.Macro Sensors
Pennsauken, NJ 08110 1334
Aug 12, 2008
Constructed of SS and hermetically sealed against hostile environments to IEC standard IP-68, LP 750 Series low voltage sensors suit hydraulic cylinder and valve position sensing within agricultural and construction equipment. Available in standard ranges of 3.75-24 in., units are offered in 3 outputs including 5 Vdc input with 0.5-4.5 Vdc output (LPVR Series), pre-calibrated, loop-powered 4-20 input/output (LPIR Series), or nominal 24 Vdc input 0-10 Vdc output (LPER Series).
|
KPSI Transducers are available with lightning protection.Pressure Systems, Inc.
Hampton, VA 23666
Aug 12, 2008
Designed for small-bore applications, Series 300 level and pressure transducers are protected against fast rising voltage transients via 2 surge protection components: one in 0.75 in. OD 316 housing of transducer and one at surface. Waterproof products withstand harsh environments that contain hostile fluids and gases and are available with option of welded 316 SS or titanium construction. Each integrates pressure sensor assembly and optional chemical-resistant ETFE cable jacket.
|
 Sensor can be daisy chained for 64 temperature points.AKCP Co. Ltd
Bangkok 10900 Thailand
Aug 11, 2008
Able to monitor temperatures between -55 to +75°C with ±0.5°C accuracy, daisyTemp comes with 5 ft sensor cable that can be extended using Ethernet cable with maximum total length of 500 ft. Up to 8 sensors can be stringed together and plugged into 1 securityProbe Intelligent Sensor port. Collected temperature values can be used to trigger alerts such as e-mail, SMS, phone calls, and SNMP traps.
|
Barometric Pressure Sensor features weatherproof housing.Onset Computer Corp.
Bourne, MA 02532
Aug 11, 2008
Able to be mounted outside weather station enclosure, Barometric Pressure Smart Sensor is compatible with web-based HOBO® U30 Remote Monitoring Systems and other weather station products. Sensor measures barometric pressure over range of 660-1,070 mb. It can be automatically recognized without complex wiring, programming, or calibration requirements.
|
Occupancy Sensors feature self-adaptive technology.LEVITON
Melville, NY 11747
Aug 08, 2008
OSSMD, OSSMD-G, and OSSMD-F combine bi-level switching with passive infrared and ultrasonic technology for accurate occupancy detection. OSSMD has dual manual-override switches to toggle on/off status of each lighting load. OSSMD-G suits retrofit applications, while OSSMD-F uses auto or manual-on for exhaust fan operation. Series is rated 800 W incandescent and 1,200 VA for magnetic low-voltage and fluorescent lighting at 120 Vac, and 2,700 VA fluorescent at 277 Vac.
|
Vibration Measurement Solutions offer remote monitoring.IOtech, Inc.
Bedford Heights, OH 44146-1833
Aug 08, 2008
With DASYLab driver support, IOtech 652u Dynamic Signal Analyzer is 10-channel, 24-bit, simultaneous sampling USB 2.0 device that offers 4 mA IEPE per channel. Allowing for connection to any eZ-TOMAS system accessible on user's plant's network, eZ-TOMAS Remote software enables single remote client to connect to multiple eZ-TOMAS systems for simultaneous remote monitoring. Additionally, single eZ-TOMAS system can serve data to multiple remote clients.
|
 RTD Thermometer System meets FDA standards.Palmer Wahl
Ashville, NC 28804
Aug 07, 2008
Wahl® DST600 uses thin-film platinum RTD sensor along with self-testing circuitry which continuously verifies electronics to ensure reading accuracy, rated ±0.3°F over -50 to +500°F temperature range. Offered as drop-in mercury-in-glass (MIG) thermometer replacement, solution is available with MIG standard tapered bulb chambers or variety of probe configurations. It meets FDA Proposed Rule change to 21 CFR Part 113 as well as current USDA 9CFR318.300 and 9CFR381.300 standards.
|
Eddy Current Flaw Detectors feature color display.GE Sensing
Billerica, MA 01821
Aug 07, 2008
Phasec 3 is single-frequency instrument for crack and corrosion detection and conductivity and coating measurements, while Phasec 3s adds dynamic rotating inspection capability and Phasec 3d adds dual-frequency capability to 3s for inspection at 2 different depths. Devices feature ¼ VGA TFT display with choice of 8 color combinations to differentiate between stored and active signals. Units have onboard memory for 200 setups and 200 traces, USB connectivity, and battery life up to 6 hr.
|
Fluorometer offers in situ characterization of water samples.Turner Designs
Sunnyvale, CA 94086
Aug 07, 2008
Incorporating 3 optical sensors, C3 Submersible Fluorometer can detect in vivo Chlorophyll a, blue green algae, rhodamine WT dye, crude oil, CDOM, optical brighteners, as well as turbidity in freshwater, coastal, and open ocean applications. C-Soft user interface enables intuitive calibration, data logging, and data management. Digital data output allows for integration with existing water monitoring systems such as CTDs, dataloggers, vessels of opportunity, and buoys.
|
(Showing headlines 3241 - 3260) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392
|
|
|