Wireless System facilitates tankhouse management.MIPAC PTY LTD
Albion Australia
Dec 03, 2008
Designed to automate cell condition monitoring in tankhouse operations, CellView® consists of Wireless Cell Monitors communicating via mesh network to central operator interface. System provides continuous, real-time monitoring of cell performance and optimizes production through early detection of process problems. It is especially suited for electro-refining and winning operations.
|
Image Sensor is designed for use in medical endoscopes.OmniVision Technologies, Inc.
Sunnyvale, CA 94089
Dec 03, 2008
Using 3 micron OmniPixel3-HS(TM) pixel, model OV6930 achieves low light performance of 3,300 mV/lx-sec. It has optical format of 1/10 in., packaged footprint of 1.8 x 1.8 mm, and image array capable of operating at 30 and 60 frames/sec in 400 x 400 and 400 x 200 resolutions, respectively. With serial I/O, which allows for 2-wire cabling up to 14 ft, sensor provides full-frame or cropped analog images in RAW RGB format and has power consumption of 80 mW with and 10 mW without I/O usage.
|
 Miniature IR Detector comes in 1 x 1 x .2 in. package.ULIS S. A. S.
Veurey-Voroize 38113 France
Dec 02, 2008
Suited for thermal camera manufacturers, UL 03 16 2 comes integrated into resistive amorphous silicon package, embeds ADC on chip, and works without requiring thermoelectric cooler. Features incldue 384 x 288 pixel array with 25 µm pitch and typical array operability of greater than 99.9%. While spectral response range is 8-14 µm, thermal time constant is less than 7 ms, and typical signal response is 3 mV/K. Solution also integrates CMOS multiplexer IC with ripple imaging operation.
|
 Line Voltage Monitor protects single-phase equipment.ICM Controls
Cicero, NY 13039
Dec 02, 2008
Featuring backlit digital display, Model ICM492 protects single-phase equipment against low and high voltage conditions and rapid short-cycling. Device continuously checks incoming line voltage for faults and displays RMS voltage. Response time on fault condition can be fine-tuned to minimize nuisance trips. Additional features include adjustable anti-short cycle time delay, control mode, universal line voltage input, and heavy-duty SPDT relay output.
|
 Ultrasonic Sensor can detect clear labels on clear web.Schneider Electric
Palatine, IL 60067-7399
Dec 02, 2008
Leveraging thru-beam technology, XUV Fork Ultrasonic Sensor can detect labels of any material, size, color, or translucency and allows for manual adjustments on-the-fly. Keys on sensor allow for real-time modifications based on material thickness, which can range from 0.001-0.003 in. Rated to IP65, sensor also can be locked to avoid unnecessary adjustments and will retain its settings even if it is powered down and turned back on. Operating range is 41 to 131°F.
|
 Hydraulic System Monitoring Unit incorporates optical sensor.Schroeder Industries LLC
Leetsdale, PA 15056-1025
Dec 02, 2008
Testmate Monitoring Unit measures solid particle contamination in hydraulic systems, and measurement accuracy is ±½ ISO code. It features automatic measurement and display of cleanliness ratings as ISO 4406:1999, SAE AS 4059, and NAS 1638. Unit has viscosity range of 46-1,622 SUS, and measures particles whose sizes are greater than 4, 6, 14, and 21 microns. Integrated pump and hoses with test point connections allow operation on reservoirs, control circuits, and high pressure circuits.
|
 Load Cell offers USB output and metric threads.FUTEK Advanced Sensor Technology, Inc
Irvine, CA 92618
Dec 01, 2008
Featuring one-piece, heat-treated 17-4 stainless steel construction, Model LCF400 is available in 500-5,000 lb with various outputs of 3 mV/V, ±5 Vdc, ±10 Vdc, and 4-20 mA. Utilizing metal foil strain gauge technology, completely welded tension and compression load cell offers linearity of ±0.10%, bridge resistance of 700 W, and deflection of 0.002-0.005 in. nominal. Standard unit can be modified or customized to meet requirements.
|
 Pressure Sensor offers pressure ranges from 0-5 to 0-15 psig.American Sensor Technologies, Inc.
Mt. Olive, NJ 07828
Dec 01, 2008
Approved to UL/cUL913 Class 1, Div 1 IS, Groups C and D with approved barrier, AST4520 suits submersible and level measurement applications. Stainless steel constructed unit operates at temperature ranges of -40 to 185°F. Media isolated, submersible pressure sensor comes with ±0.25% BFSL accuracy, EMI/RFI protection of 100 V/meter and a 4-20 mA output. Flush Diaphragm Steel Cage design allows for proper flow of media while keeping sensor at bottom of tank or well.
|
Network Monitoring Software has data reporting feature.Softinventive Lab
Seattle, WA 98124-1069
Dec 01, 2008
With ability to build detailed report on type and time of error or failure, Total Network Monitor v.1.0.1 controls user network, separate computers, and network and system utilities continuously. Software checks HTTP, FTP, SMTP/POP3, IMAP, event log, service state, and registry servers. It also alerts user in case of failures and unpredictable errors.
|
 Probes measure air flow at inlet section of fan.Dwyer Instruments, Inc.
Michigan City, IN 46361
Nov 28, 2008
Series FAFM Fan Inlet Air Flow Measuring Probes utilize evenly distributed total and static pressure measuring points to measure flows in fan inlet. Installed from outside of fan, lightweight, durable units can be ordered to fit inlets with diameters ranging from 6-96 in.
|
 Dual Axis Inclinometer Sensor detects angular tilt.Turck USA
Minneapolis, MN 55441
Nov 26, 2008
Featuring compact rectangular housings that can be mounted at ±10, ±45, ±60, and ±85° angles, Dual Axis MEMS Inclinometer Sensor measures angular tilt in reference to gravity. It incorporates micro-electro-mechanical capacitive element, and IP67 rated unit provides 2 analog outputs of 0.1-4.9 Vdc or 2 current outputs of 4-20 mA, and operates in -30 to 70°C temperatures.
|
 Gas Detector reads over 30 gas concentrations.Analytical Technology, Inc.
Oaks, PA 19426
Nov 25, 2008
Targeting water and wastewater treatment applications, 2-wire, loop-powered Model D12 uses electrochemical sensor for toxic gases and catalytic bead for combustible gases, which offer accuracy levels of ±10% of value. Unit includes AutoTest feature, which generates small sample of gas every 24 hours to verify operation. Device features menu-driven set up pages and large LCD numerical display so gas values can be read along with alarm indication.
|
 Voltage Monitor features adjustable trip and restart delay.Time Mark Corp.
Tulsa, OK 74116 2019
Nov 25, 2008
Offered as MCU-based sensing circuit, Model 16-1 protects equipment from over, under, over/under voltage, and rapid cycling conditions. Trip and restart delays are respectively adjustable from 0-30 and 0-300 sec or can be disabled. Input voltages for alternating low range and high range versions is 12-30 Vac/Vdc and 30-277 Vac, respectively, and response time is 48 msec (less than 100 mS with relay flight time). Surface-mount and 8-pin socket versions are available.
|
 Dissolved Oxygen Sensor withstands pressures up to 145 psi.Electro-Chemical Devices, Inc.
Yorba Linda, CA 92887
Nov 25, 2008
Featuring maximum error rate of less than 2%, Triton DO8 offers repeatability of ±0.5% and resolution of 0.01 ppm or 0.01% saturation. It provides 3 different outputs including 0-20 ppm, 0-200% saturation, or 0-500 psi, withstands ambient temperatures from 0-140°F, and records measurements at 20-120°F. Self-monitoring unit uses fluorescence quenching (FQ) optical technology coupled with microprocessor-based electronics, and stores calibration data within sensor.
|
Marine Electronics provide HD view of fish and ocean bottom.Lowrance
Tulsa, OK 74128
Nov 25, 2008
Featuring GPS-Chartplotter and Fishfinder combination units, HDS-5, with 5 in. 480 x 480 pixel cold-cathode display, and HDS-7, with 6.4 in. 640 x 480 pixel VGA display, incorporate Lowrance Broadband Sounder technology that eliminates clutter/noise in water column. Devices include 16-channel GPS+WAAS antenna and backlit screens and keypads. Compatible with Lowrance HD radar systems, waterproof units can operate standalone or be integrated via Ethernet and NMEA 2000 networks.
|
 Automatic Video Trackers fuse images from multiple sources.GE Intelligent Platforms
Charlottesville, VA 22911
Nov 24, 2008
When configured with IMP20 Video Processing Mezzanine Card, ADEPT104 and AIM12 provide system for detecting, tracking, stabilizing, and fusing images from multiple sensors and cameras in real-time. Full-frame, multi-resolution image fusion algorithm enables intelligent management and interpretation of multiple parallel visual information streams. Also included, warp engine provides rotation, scaling, and translation for each video source to compensate for distortion/misalignment.
|
Position Sensor features on-chip digital encoder.New Scale Technologies
Victor, NY 14534
Nov 24, 2008
Offering alternative to miniature optical encoders, TRK-1T02 TRACKER Magnetic Sensor offers 2 µm resolution and can be used as linear encoder or off-axis rotary encoder. Measuring 8.5 x 11.5 x 1.61 mm, unit does not require light source and is insensitive to external light, shock, vibration, and high-particulate environments. On-chip encoder provides direct digital output using standard I2C protocol, eliminating need for external pulse counters.
|
Liquid Level Sensor features multipoint switch capability.Gems Sensors Inc.
Plainville, CT 06062
Nov 24, 2008
Intended for non-contact applications, UCL-510 Ultrasonic Level Sensor combines 4 relays, 4-20 mA output, and pump/valve control in one unit for total fluid handling and automation solution. Product is built for small tank applications (49.2 in. or less) and offers switch, controller, and transmitter capabilities. Featuring 2 in. dead band and PC interface for configuration, sensor is suited for corrosive and dirty applications and is virtually maintenance-free.
|
 Torque Tester is modular, programmable, and PC-controlled.Mark-10 Corp.
Copiague, NY 11726
Nov 21, 2008
Accommodating range of applications, TSTM-DC motorized torque test stand offers 100 lb-in. capacity and integrated angle indication with RS-232 data output. Modularity enables configuration to test requirements, while lever-operated slider with travel stops facilitates and accelerates sample engaging and disengaging. While able to be fully controlled by PC, universal tester can also be configured to stop at or cycle between programmable angle limits or torque limits.
|
 Mass Flow Meter withstands temperatures up to 850°F.Fluid Components Intl.
San Marcos, CA 92069 5115
Nov 21, 2008
Suitable for pipe sizes from 2.5-120 in., Model ST98HT measures air/gas mass flow rate, totalized flow, and temperature in single instrument. Insertion-style unit is designed with direct mass flow sensing element that is accurate to ±1% of reading, and ±0.5% of full scale, with repeatability of ±0.5% of reading. Operating over flow range from 0.75-600 sfps with turndown ratio up to 100:1, meter provides linearized 4-20 mA output and HART 2-way communications.
|
(Showing headlines 2381 - 2400) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362
|
|
|