Sensors, Monitors & Transducers
(Showing headlines 2201 - 2220) << 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 ...
|
Reference Design accelerates wireless sensor design.Freescale Semiconductor
AUSTIN, TX 78735-8598
Dec 04, 2009
Providing 2 portable demo boards, one sensor transceiver board, and one USB receiver board, RD3965MMA7660FC ZSTAR3 reference design facilitates demonstration and evaluation of accelerometer-based applications with low-power wireless connectivity. Included MMA7660FC triple-axis accelerometer enhances mobile phone and small appliance UIs with features such as tilt orientation and gesture detection. Wireless communication is enabled by 16-channel MC13213 ZigBee-ready 2.4 GHz transceiver.
|
 Load Measuring Pins can suit any mechanical arrangement.Applied Measurements Limited
Aldermaston, Berkshire RG7 8PN United Kingdom
Dec 03, 2009
Manufactured from precipitation-hardened stainless steel, DBEP series can be designed/customized to suit existing mechanical arrangements. Amplifiers are available within load pin head to increase output signal to 0-10 Vdc, 0-5 Vdc, or 4-20 mA when low-level signal needs to overcome lengthy cable runs to instrumentation. Sealed to IP67 as standard or IP68 optionally, pins offer standard capacities from 2.5-50 tons, although load capacities are often supplied from 200 kg to 1,500 tons.
|
 Reflective Electro-Absorption Modulator has 60 GHz bandwidth.CIP Technologies
Ipswich United Kingdom
Dec 03, 2009
With insertion loss of only 3.6 dB, combined modulation and photodetection transducer 60G-R-EAM-1550 provides digital optical modulation at 50 GBps, RF modulation over 60 GHz bandwidth, and photodetection with 1.0 A/W responsivity and 43 GHz bandwidth. It operates across 1,550 Nm C-band with low chirp parameter and is designed for use with laser diode source. It is available in custom variants, standard package with RF connectors is suited for use with external RF components/drivers.
|
Acoustic Volume Indicator finds liquid/gas levels in metal tanks.Young Engineering Mfg., Inc.
San Dimas, CA 91773
Dec 03, 2009
Acoustic Volume Indicator Technology is non-intrusive means to determine liquid or gas volume in pressurized or non-pressurized metal tanks. Components include transducer, impactor, and waveform analyzer software that calculates peak frequency from input signal. Able to work in range of temperatures, pressures, installation connections, and fluid specific gravities, 3 versions are available: AVI Automated which includes alarms and remote signals, AVI Laptop, and AVI Handheld.
|
 Locking Safety Door Switches provide 3,000 N holding force.Omron Scientific Technologies Inc.
Fremont, CA 94555
Dec 02, 2009
Designed for locking large and heavy doors, IP67 rated D4JL guard locking safety door switches feature rear release buttons to allow workers to unlock switch from inside protected area and exit hazardous areas. Two safety circuits and 2 monitor contacts provide array of monitoring patterns, including monitoring open/closed status of door and status of lock. Standard gold-clad contacts enable use with microloads and ordinary loads. Trapped key models are also available.
|
Nitric Oxide Sensor delivers accuracy to 10 ppb.City Technology Ltd
Portsmouth PO6 1SZ United Kingdom
Dec 02, 2009
Developed specifically for medical applications, NO sensor allows manufacturers of breath monitoring equipment to develop smaller instruments. Design does not require sample of exhaled breath to be adjusted to particular temperature or pressure to achieve reliable reading, and only 10 sec exposure is required to achieve reading with resolution down to 10 ppb. Operating over 10 to 30°C range, product is rated for 2,000+ exposures and operates on catalytic, non-consumable principle.
|
Digital Triaxial Accelerometer enhances touch recognition.Bosch Sensortec
Reutlinge 72770 Germany
Dec 02, 2009
Supplied in 3 x 3 x 0.9 mm package, BMA120 recognizes spatial position and positional changes of mobile devices and classifies them within random movement, rotational movement, tapping, and fast/slow categories. Programmable interrupt controller directs mobile phone functions according to targeted movements of device. Supporting 4 programmable measuring ranges from ±2 to ±16 g, sensor provides SPI and I²C interfaces and interrupt output as well as low-power and programmable sleep modes.
|
 Laser Profile Sensors are available with 50 mm range.Micro-Epsilon UK Ltd
Cheshire United Kingdom
Dec 01, 2009
Supplied in compact housing with integrated controller, scanCONTROL 2700/2710 series are typically used to measure angles, steps, and positions in automation solutions where space is restricted. Same is also possible for profiles such as adhesive beading, weld seams, grooves, and gaps. While scanCONTROL 2700 acts as pure data supplier and provides measured points, scanCONTROL 2710 calculates information directly in sensor.
|
 Contact-Free Capacitive Level Switch provides complete media compatibility.Sensortechnics, Inc.
Walpole, MA 02081
Dec 01, 2009
Utilizing non-invasive capacitive sensor technology, CLW series detects point levels of liquids and granular or pulverized materials without contacting media. User can adjust high and low switch point with hysteresis of less than 1 in. Product mounts to outside of container or vessel and can measure through almost any nonmetallic wall material. Its reference electrode compensates for all changes in ambient environmental conditions such as temperature and humidity.
|
Bipolar Hall Sensors detect magnetic field quickly, safely.Seiko Instruments GmbH
Neu-Isenburg Germany
Dec 01, 2009
Operating from 4-5.5 V supply, N- and S-pole sensing Hall-sensor series S-5721A/22A/23A are laid out in CMOS with Push-Pull or N-Ch-Open-Drain Output. Detection frequency of 7.6 kHz corresponds to 0.132 ms detection period and current consumption of 0.95 mA in pulsed S-5722A, while continuous-duty S-5723A exhibits 3 mT/-3 mT typ sensitivitya and is packaged in SOT-23-3 that can dissipate 430 mW. Requiring 0.08 mA, S-5721A has 0.63 KHz detection frequency and 1.58 ms detection period.
|
 Hose Whip Restraint prevents operator/equipment damage.Parker Hannifin Corp., Hose Products Division
Wickliffe, OH 44092 1797
Nov 30, 2009
Comprised of hose collar and hose assembly, Hose Whip Restraint limits whip/travel of pressurized hydraulic hose after it breaks free from its fitting to enhance safety for nearby operators/equipment. This helps avoid financial and legal ramifications for company in addition to minimizing downtime and lost revenue. Available with cable assemblies for flange-type connections and port adapters, restraint employs steel cord to keep hose fastened to fitting after breakage occurs.
|
 Liquid Vortex Flow Sensor also directly measures temperature.Clark Solutions
Hudson, MA 01749
Nov 30, 2009
Designed for equipment manufacturers for system flow monitoring and control, DN Series operates on Karman's vortex trail principle, handles flow ranges from 0.24-39.6 gpm, and is accurate to 1% FS of measured value. Piezoelectric sensors embedded in ETFE vane located downstream of bluff detect generated vortices, and measured frequency represents flow velocity. This results in temperature-insensitive measurement of flow with minimal pressure loss.
|
 Authentication System provides counterfeit protection.STMicroelectronics
Lexington, MA 02421
Nov 30, 2009
Based on ST23 microcontrollers and secure operating system, AuKey turnkey solution helps brand owners authenticate products such as computer accessories, add-in cards, printer cartridges, network infrastructure products, and metering devices. AuKey supports advanced security crypto algorithms including AES shared-key system and Elliptic Curve Cryptography. Microcontroller and OS, together, also secure chip's data-read and data-write mechanisms.
|
 Quadrature Encoder is IP65 protected from dust/water.CUI, Inc.
Tualatin, OR 97062
Nov 30, 2009
Offering 2-bit quadrature resolution with square wave output signal, C14 panel mount optical encoder suits application in industrial equipment, portable communication equipment, and medical equipment. Series has 16 or 32 angle of throw position along with 3 shaft options that include 3.175 mm with slotted end, 6 mm dia round, and 6.35 mm with D-cut. Termination options included are solder holes, 130 mm cable with connector, and pcb or panel mount.
|
 Quadrature Encoder is IP65 protected from dust/water.CUI, Inc.
Tualatin, OR 97062
Nov 30, 2009
Offering 2-bit quadrature resolution with square wave output signal, C14 panel mount optical encoder suits application in industrial equipment, portable communication equipment, and medical equipment. Series has 16 or 32 angle of throw position along with 3 shaft options that include 3.175 mm with slotted end, 6 mm dia round, and 6.35 mm with D-cut. Termination options included are solder holes, 130 mm cable with connector, and pcb or panel mount.
|
 SF Fill Level Sensors suit sanitary filling applications.Balluff, Inc.
Florence, KY 41042-0937
Nov 30, 2009
Made from corrosion-free stainless steel with rounded edges and minimal crevices, 3-A and EHEDG sanitary standards certified Micropulse SF fill level sensor uses field-tested magnetostrictive technology to provide high-precision fill level measurement. Continuously-variable analog output signals allow for connection to control systems. Units are chemically neutral for all liquids, and can withstand process temperatures up to 130°C.
|
Solid-State MEMS Inclinometers have ±1 mrad accuracy.Sherborne Sensors Limited
Hampshire RG21 6YH United Kingdom
Nov 30, 2009
Model T710 measures inclination proportional to sine of angle in one axis, while T720 measures inclination in dual axes at right angles. Available in ranges from ±30 to ±90°, compact DC-operated inclinometers feature MEMS sensor incorporating air damping that is independent of temperature, allowing unit to perform over wide temperature range. They are resistant to shock and operate from unregulated DC power source, and offer self-test feature on both axes.
|
 PIN/Proximity Card Reader enables secure, keyless entry.Southco
Concordville, PA 19331 0116
Nov 27, 2009
Self-contained EA-P1 facilitates transition from mechanical to electronic access while increasing security. LED and audible beeper provide feedback during software-free programming, and programmable output timing supports multiple access arrangements. Able to accommodate multiple users via support for up to 5 unique PIN codes and 9,999 proximity cards, access management solution also includes relay output that integrates directly with electronic locks.
|
 Differential Pressure Gauge features surface mount design.Sensocon, Inc.
Lakeland, FL 33801
Nov 25, 2009
Designed to measure positive, negative, and differential pressure, S9000 Differential Pressure BoxGauge(TM) mounts to any wall or vertical flat surface. Box shape also allows gauge to sit on any flat horizontal surface. Featuring 3 in. face, gauge provides 5% overall accuracy and is supplied with pressure connections at top and back for 3/16 in. tubing. Applications include monitoring filter status, duct static pressure, dust collectors, fan and blower pressure, or other HVAC equipment.
|
Optocouplers detect voltage and current thresholds.Avago Technologies
San Jose, CA 95131
Nov 25, 2009
Suited for industrial control applications, ACPL-K370/K376 detect AC/DC sources and convert voltage to logic interface across optical coupling barrier to provide safe isolation in electronically noisy environments. Threshold sensing input buffer ICs permit control of threshold levels over wide range of input voltages up to 1,140 Vpeak, with single external resistor. Housed in SO-8 package, detectors operate from -40 to +105°C and meet 8 mm clearance and creepage requirements.
|
(Showing headlines 2201 - 2220) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395
|
|
|