Sensors, Monitors & Transducers
(Showing headlines 1781 - 1800) << 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 ...
|
 Safe Pressure Reactor prevents accidental explosion.Q Labtech LLC
Waterford, CT 06385
May 25, 2010
Q-Tube(TM), with pressure release and reseal system, prevents accidental explosions due to over-pressurization. With 200 psi working pressure, product is used in applications requiring high yields, clean products, and fast reactions. Rated for 150 gal of water per refluxed reaction, maintenance-free unit can be operated safely and accurately to promote reproducibility with range of gases: ammonia, nitrogen, argon, hydrogen, deuterium, CO, CO2.
|
 Non-Contact Powder Thickness Gauge uses ultrasonic technology.DeFelsko Corp.
Ogdensburg, NY 13669
May 25, 2010
PosiTector PC Powder Checker uses ultrasonic technology to measure uncured powder coatings and automatically calculates and displays predicted cured thickness. Allowing measurement on small tubes, odd shapes, and moving parts, it features internal memory of up to 1,000 readings with no software required for downloading. Unit continually displays/updates basic statistics and generates formatted reports with measurement summaries and charts.
|
 Precision Linear Servo Accelerometers are sealed to IP65.Sherborne Sensors Limited
Hampshire RG21 6YH United Kingdom
May 25, 2010
Designed for use within low acceleration analysis, structural health monitoring, flight test, and civil engineering applications, 4-20 mA A323 L-series sensors have measurement range of ±0.1 to ±2.0 g, with frequency response down to DC. Gravity referenced, closed loop sensors monitor acceleration down to 20 µg and withstand up to 1,500 g of mechanical shock. Housed in IP65 rated anodized light alloy case, sensors can be specified with 6-pin Bayonet lock or solder pin connector.
|
Voltage and Current Monitor targets grid-connected systems.austriamicrosystems AG
Premstatten Austria
May 25, 2010
Housed in 4 x 4 mm QFN-16 package, Model AS8002 delivers sensed voltage and current in high-resolution digital format and is intended for grid connected systems such as solar photovoltaic inverters. Flexible front-end provides adjustable gain to accommodate various resistor values, while on-chip calibration allows compensation for external component inaccuracies and variations over temperature. Operating from 3.0-3.6 V, IC is specified for temperature range of -40 to +125°C.
|
Portable Fault Locator accommodates various cable types.GAO Instruments Inc.,
Toronto Canada
May 25, 2010
Using TDR technology, model A0680005 can test line breaks and short circuit faults in twisted-pair, data, high-frequency, and coaxial cables. Standard features include HD backlit LCD screen, test blind zone of less than 2 m, and comparison test function. Able to test 25, 50, 75, and 100 ohm impedance cables, instrument also provides electronic map relevant to time domain and respectively supports minimum test distances of 2,000 and 8,000 m in line short and line break testing.
|
Dual Voltage Phase Monitor covers 200-240, 425-525 Vac ranges.Motor Protection Electronics, Inc.
Apopka, FL 32703
May 25, 2010
Featuring dual adjustment ranges, Model 001-DVM-118 monitors for under voltage, phase reversal, and phase imbalance. Plug-in, 8-pin unit has one SPST output relay rated 10 A @ 240 Vac and one additional NO contact between pins 6 and 7. This additional contact carries same rating and closes as well when correct voltage is supplied. With correct voltage applied, internal relays will energize and LED illuminates, allowing normal operation.
|
12-Pin Phase Monitor offers dual adjustment ranges.Motor Protection Electronics, Inc.
Apopka, FL 32703
May 25, 2010
With adjustment ranges of 200-240 or 425-525 Vac, 12-pin Model 001-DVM-1212 monitors for under voltage, phase reversal, and phase imbalance. Plug-in style unit has one DPDT output relay rated 10 A at 240 Vac. With correct voltage applied, internal relay energizes and LED illuminates, allowing normal operation. Abnormal condition causes LED to blink during trip delay, and when trip delay has expired, internal relay will be de-energized. LED then provides pulses that indicate fault condition.
|
 Miniature Inductive Proximity Sensors have range up to 1 mm.Pepperl + Fuchs, Inc.
Twinsburg, OH 44087 2245
May 24, 2010
Suited for detection of small and narrow metal targets, Miniature Inductive Proximity Sensors are available in 3 and 4 mm dia stainless steel housing with smooth or threaded barrel and deliver sensing range up to 1 mm. They also feature LED indication and 2 m PUR cable. Available with normally open NPN or PNP outputs, sensors offer 3-wire, 10-30 Vdc connectivity and max switching frequency of 1,300 Hz.
|
Limit Switches minimize tampering with equipment safeguards.Eaton Corporation
Raleigh, NC 27615
May 24, 2010
Comprised of over 100 models, LS-Titan(TM) Series includes safety limit switches and safety interlock switches, all with positive opening contacts per IEC and EN 60947-5-1. Miniature-DIN safety limit switches feature modular design with interchangeable heads that can be rotated in 4 directions. Depending on application requirements, switches are supplied in insulated plastic or metal enclosures. Electronic safety position switch with solid-state outputs is also available.
|
 Wireless Temperature Transmitter relays multiple parameters.Comark Corp.
Medfield, MA 02052
May 21, 2010
With inputs of current and voltage, RF515 can be connected to control loop and programmed to measure range of parameters: pressure, gas, flow, level, dissolved oxygen, CO2, and more. LCD screen displays local temperature at point of measurement, while LEDs allow checks of active/alarm indication in situ. Along with selectable scales, transmitter features BioCote®-protected surfaces that inhibit growth of bacteria, mold, and fungi.
|
 Relative Humidity and Temperature Transmitter can output data as analog signal.Rotronic Instrument Corp.
Hauppauge, NY 11788
May 21, 2010
Based on HygroClip2 probe fitted with AirChip3000 technology, HygroFlex5 Series provides compensation of humidity and temperature at 30,000 reference points, recording of 2,000 data points, and calculation of current dew point. If sensor accuracy declines significantly, AirChip3000 recognizes problem and will issue alarm. Available in duct-mounted and wall-mounted versions, transmitters enable any psychometric calculation to be output as analog signal.
|
 Portable Combustible Gas Sniffer has range from 0-10,000 ppm.E Instruments International LLC
Langhorne, PA 19047
May 21, 2010
Featuring 11 in. fully flexible probe for hard-to-reach places, hand-held Model 7899 is equipped with highly sensitive tip to pin-point small leaks of any combustible gases and hydrocarbons from piping and/or appliances. Quick response leak detector features auto zero-drift adjustment, audio alarm, HOLD function, and large visual LCD and bar graph display. Readings are provided in ppm, %vol, and %LEL.
|
 Thickness Measurement Sensor has dual sensor design.Micro-Epsilon UK Ltd
Cheshire United Kingdom
May 20, 2010
Model KSH5 includes both capacitive and eddy current sensors that measure continuously in one axis on same measuring spot to provide precise thickness measurement. Used for single-sided thickness measurement of plastics, compact unit features 5 mm range and also feature integrated temperature measurement. Combination connector allows all output signals to be transmitted in single connection cable, and using KSS6380 controller with Ethernet interface, product can be configured via Web browser.
|
 Linear Position Sensors offer stroke lengths up to 300 mm.Novotechnik U.S., Inc.
Southborough, MA 01772
May 20, 2010
Featuring 18 mm diameter housing that is sealed to IP67, TX2 Series offers linearity to 0.05% with resolution better than 0.01 mm. Pivot heads provide large angle of free movement up to ±12.5°. Available from stock with 8 stroke lengths from 25-300 mm, sensors operate for more than 50 million movements and withstand adverse environmental conditions such as humidity and dust.
|
 MEMS Vibration Sensor offers programmable functions.Analog Devices, Inc.
Norwood, MA 02062-9106
May 19, 2010
Tri-axis ADIS16223 iSensor® accelerometer combines iMEMS® technology with signal processing, data capture, and SPI that supports various configuration options. Available in ±70 G dynamic range, unit has 22 kHz sensor resonance and 72.9 kS/sec sample rate that provide flat frequency response from DC to 10 kHz. Sensor features data capture function with 3 different trigger modes. It also provides digital temperature sensor, power supply measurements, and peak output capture.
|
 MEMS Microphones enable Hi-Fi audio in portable devices.Analog Devices, Inc.
Norwood, MA 02062-9106
May 19, 2010
Respectively delivering flat wideband frequency response from 100 Hz to 15 kHz and 200 Hz to 15 kHz, ADMP404 and ADMP405 iMEMS® microphones promote voice quality without background noise in portable electronics. Microphone functions include Hi-Fi A/V playback, hands free communication, and voice recognition. Also offering TIA-920 compliance for VoIP applications, products have 62 dB A-weighted SNR and 80 dBV PSRR with integrated high-pass filtering.
|
 Magnetic Angle Position Sensor features SAE SENT J2716 interface.austriamicrosystems AG
Premstatten Austria
May 19, 2010
Designed for accurate angular measurement over full 360°, system-on-chip model AS5165 features SENT J2716 interface for simple transmission of high-resolution sensor information. It provides protection for power supply and output pins against overvoltage up to 27 V. Power supply pins are also protected against reverse polarity to -18 V. AEC-Q100 grade 0 qualified, device features analog front-end and digital signal processing, and operates from 5 V supply over -40 to +150°C.
|
 CO2 Gas Sensor delivers measurement accuracy of ±100 ppm.Forston Labs
Fort Collins, CO 80524
May 18, 2010
Designed for use with LabNavigator® instrument for continuous monitoring, time-based experiments, or routine monitoring applications, CO2 gas sensor offers 0-10,000 and 0-100,000 ppm measurement ranges. It features resolution of 3-30 ppm, and operates at temperature of 25°C and humidity range of 5-95% (non-condensing). Response time is 95% of full scale reading in 120 sec. Sensor is suited for monitoring CO2 levels in ambient air, respiration of organisms, or reactions in chamber.
|
Signal Monitoring System suits DVB-T and DVB-H networks.Rohde & Schwarz GmbH & Co
Germany
May 18, 2010
Able to measure modulation error ratio (MER) up to 38 dB, R&S DVMS1 simultaneously monitors MPEG transport stream and transmitted RF signal. Signal from transmitter's monitoring output is fed directly to device and main RF characteristics such as level, frequency, and MER can also be measured. Other functions include PCR jitter analysis and display of thumbnails and EPG. Unit offers 2 signal inputs and allows user configuration of all monitoring functions.
|
Circuit Fault Tester assists telecom technicians.GAO Instruments Inc.,
Toronto Canada
May 18, 2010
Designed to work continuously for 10 hours when fully charged, Model A0310006 tests for breaks, shorts, and defective insulation as well as telephone state and line voltage. Unit can detect wire breaks at distances up to 9 km within 1 m tolerance, and offers 3 optional cable sizes for local communications lines, including 0.32, 0.4, and 0.5 mm. Additional functions include loop resistance measurement, dielectric resistance measurement, and line alignment.
|
(Showing headlines 1781 - 1800) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393
|
|
|