 Fire Control Panel has reporting features for DACT circuit.Fire Control Instruments, Inc.
Waltham, MA 02451 1122
Oct 31, 2003 Series 7100 multiprocessor-based fire control panel system comes with Windows®-based Field Configuration Program (FCP-7100)/System Operating Software (SOS) v6.1. It enables control panel to read specific sensitivity level of each sensor and allows system to compensate for changes due to age, dust accumulation, or other environmental factors. Software includes 4 conditions viewable on display to aid in isolating DACT FAULTS conditions. |
 Horizontal Fire Sprinklers offer 16 x 22 ft coverage area.Viking Corp., The
Hastings, MI 49058 9706
Oct 30, 2003 Residential Horizontal Sidewall 4.2K Sprinklers include UL listing for residential installations below smooth, flat, horizontal ceilings at both 4–6 and 6–12 in. down from ceiling. They are also listed below sloped ceilings with up to 8/12 pitch. Available with 155°F and 175°F temperature ratings, sprinklers come in brass, chrome, and white finishes, and can be installed surface-mounted or recessed. |
 Fire Suppression System installs on vertical carousels.Remstar International, Inc.
Westbrook, ME 04092
Oct 10, 2003 Pneumatically-operated Fire Suppression System features tube system installed near high-risk fire areas in vertical carousel that operates as detection and suppression device. If controls or motor overheat, high temperature causes tubing nearest hot spot to burst, releasing pressurized fire suppression agent directly on source of heat, extinguishing hot spot and minimizing collateral material and equipment damage. |
 Air Quality Sensor has 0–0.6 mg/m³ range.Sharp Microelectronics
Camas, WA 98607 9489
Sep 05, 2003 Model GP2Y1010AU detects particulate matter, smoke, or dust suspended in air. Unit measures 46 x 30 x 17.6 mm, operates on 5.0 V, and has current dissipation of less than 20 mA. Suited for air purifiers and air cleaning systems, device may also be used in various industrial applications. When used in smoke detection system, unit triggers alarm or system shut-down in case of burning or overheating conditions to prevent damage to automated equipment. |
 Concealed Sprinklers suit commercial applications.Viking Corp., The
Hastings, MI 49058 9706
Sep 04, 2003 Commercial Concealed Sprinklers with domed covers offer alternative to flat-plate sprinklers. Standard and quick response units are available for standard and extended coverage applications in 5.5, 8.0, and 11.2 K models. Cover has push-on, pull-off design and may be removed without taking system out of service. |
 Control Panel controls release of extinguishing agents.Simplex
Westminster, MA 01441
Jul 17, 2003 Simplex® 4004R Suppression Releasing Panel suppresses fires in computer rooms, petrochemical and power plants, and high-risk locations. Product controls release of extinguishing systems such as Inergen®, FM-200, preaction, water spray deluge, and carbon dioxide. Capable of handling one or two hazard areas, product also provides emergency notification using horns or strobes. Panel can capture detailed history of all trouble, alarm, and releasing events. |
 Sprinklers are UL and cUL listed.Viking Corp., The
Hastings, MI 49058 9706
Jul 03, 2003 Installed below smooth, flat, horizontal ceilings and horizontal ceilings with beams up to 14 in. deep, 4.9 K-Factor Frame-Style Residential Pendent Sprinkler provides coverage areas of up to 18 x 18 ft. Product is approved for temperatures up to 175 °F. With domed cover providing ½ in. adjustment, 4.9 K-Factor Concealed Residential Sprinkler provides 12 x 12 through 18 x 18 ft coverage areas and is approved for temperatures to 155 °F. |
 Firestop Plug seals wires in walls and floors.Hilti Inc.
Tulsa, OK 74121
Jun 30, 2003 Designed for permanently or temporarily sealing single or bunched cables in fire walls and floors, model CP 658 flexible, intumescent plug is reusable and repenetrable. Suited for cored or round holes, it provides dust- and fiber-free solution for meeting building and fire codes. Halogen-, asbestos-, and solvent-free plug can be used with FS 657 Fire Block, CP 618 Firestop Putty Stick, and CP 617 Firestop Putty Pad. |
 Trim Units connect to valves via flexible hoses.Viking Corp., The
Hastings, MI 49058 9706
Jun 12, 2003 Available for single and double interlock preaction and deluge, TrimPacâ„¢ pre-assembled, pre-tested trim units can be used with angle-style or straight-through valves. UL/c-UL Listed and FM Approved Products may be used on any size valve in 1½â€“8 in. sizes and can be mounted on wall or on riser. They connect to valves with flexible hoses and come complete with galvanized conventional trim as well as appropriate release trim. |
 Fire-Alarm Panel is compatible with non-shielded wires.Faraday, LLC
Tecumseh, MI 49286
Jun 03, 2003 MPC-1500 Plus intelligent fire-alarm control panel employs UL-approved driver circuit. Loop circuit can operate with straight-laid, non-twisted, non-shielded wire in retrofit applications. Panel features 80-character LCD display, analog addressable detection, programming, and memory capability. It accepts expansion modules to include up to 8 D/B initiating zones. Operating controls and indicators are mounted on door, with mylar label for identification. |
 Fire Detector Tester reduces programming and test times.Siemens Building Technologies Inc.
Florham Park, NJ 07932
Jun 03, 2003 Device Program Unit, for diagnostic testing of fire detectors, is for programming MXL and XLS devices and testing XLS circuits and may also be used as XLS loop circuit driver. Unit operates on rechargeable NiMh or Alkaline batteries, has optional label printer, uses FLASH memory, and has backlit screen. Unit has DB-3S base adapter for testing and programming ILI and ILP series detectors. |
 Fire Protection System is rated to 250 psi.Viking Corp., The
Hastings, MI 49058 9706
May 05, 2003 TotalPac2 fail-safe, fire protection units are built on company's EZ Trim and are available in Dry, Deluge, Single-, and Double-Interlock Preaction and Firecycle® III systems. Three models include skid containing pre-assembled trim on 14 ga steel base, remote controlled unit without integrated panel, and fully equipped self-contained unit. Pre-assembled, pre-tested models come in sizes from 1-1/2 to 6 in. and are UL and C-UL Listed.
|
 Residential Sprinkler offers large K factor.Viking Corp., The
Hastings, MI 49058 9706
May 05, 2003 Model K-5.2 Residential Concealed Pendent Sprinkler offers 18 x 18 ft and 20 x 20 ft coverage areas and is approved for 155°F/68°C temperature. Domed cover provides ½ in. adjustment. Sprinkler is UL and cUL listed for residential occupancies below smooth, flat, and horizontal ceilings. |
 Pendent Sprinkler features decorative finishes.Viking Corp., The
Hastings, MI 49058 9706
Apr 09, 2003
Residential Pendent Sprinkler offers 18 x 18 ft and 20 x 20 ft coverage areas with competitive flows in coverage areas as low as 12 x 12 ft. With 5.2 K-factor, VK436 sprinkler is UL Listed for residential occupancies below smooth, flat, horizontal ceilings. It is approved for 155?F and 175?F temperatures, is available in various decorative finishes, and can be surface-mounted or recessed.
|
 Pendent Sprinkler has 25.2 K-factor.Viking Corp., The
Hastings, MI 49058 9706
Apr 09, 2003 Roof-mounted VK510 ESFR meets FM guidelines for protecting buildings to 45 ft high that have storage to 40 ft high. It protects common storage materials from severe-challenge fires of palletized and solid pile storage, from Class I commodities to rubber tires. Guidelines for installation allow maximum deflector-to-ceiling distance of 18 in. With sturdy link design and protective shipping caps, product is less vulnerable to damage than rack-mounted sprinklers. |
 Intelligent Fire Detector System provides background music.Siemens Building Technologies Ltd.
Sudbury, ON P3A 2A3 Canada
Feb 13, 2003 FireFinder incorporates audio system with 8-channel digital voice amplifiers that operate in 200 Hz to 12 KHz range. System is used for voice/evacuation emergency notifications and can also provide building-wide communication with surround-sound music and paging. Its 6 in. interface screen simultaneously displays up to 5 events using HAZMAT icons for safety and highlighting critical information. Interface also displays locator maps. |
 Vehicular Fire Protection System uses suppresing powder.F.I.R.E. Panel LLC
Scottsdale, AZ 85206
Dec 10, 2002 FIRE Panelâ„¢ helps prevent fires caused by rear-end collisions by encasing vehicle's fuel tank with custom-formed, 3D, polymer panel that contains fire-suppressing powder. Unaffected by low-speed accidents, system's shape wraps around sides of fuel tank to provide additional protection during skewed angle collisions. Upon impact, panel shatters, releases powder, and renders space around tank inert, preventing ignition of fuel or suppressing fire. |
 Fire Sprinklers meet UL residential density requirements.Central Automatic Sprinkler Co.
Lansdale, PA 19446
Dec 09, 2002 UL-listed LFII pendent sprinklers install in beamed ceilings, including vaulted and sloped styles. They provide min density/water application requirement of 0.05 gpm/ft² for single-family and multi-story residential occupancies and 0.10 gpm/ft² for high-rise occupancies greater than 4 stories in height. With sprinkler spacing of 18 x 18 ft, minimum water application is 16.2 gpm for the former and 32.4 gpm for the latter. |
 Horizontal Sprinkler addresses changes in UL 1626.Viking Corp., The
Hastings, MI 49058 9706
Nov 11, 2002 Model VK488 Residential Horizontal Sidewall Sprinkler offers 4.3 K-factor and adjustment up to 5/8 in. when installed in recessed escutcheon. Unit is UL Listed for residential occupancies below smooth, flat, horizontal ceilings and approved for 155 and 175°F temperatures. Depending on water supplies, it can be installed at 4 to 6 in. or 6 to 12 in. down from ceiling. |
 Suppression System extinguishes engine compartment fires.Firetrace International
Scottsdale, AZ 85260
Oct 01, 2002 Firetrace® Fire Suppression System requires no electricity or external power. Polymer tubing can be routed anywhere within engine compartment. When exposed to open flame, tubing ruptures, dispensing entire contents of cylinder containing fire-suppression agent such as FM-200®, C02, dry chemical powders, and foam. System is totally self-contained and helps prevent extensive vehicle damage. It is suitable for enclosed spaces within vehicles of 250 ft³ or less. |