|
|
|
|
Safety & Security Equipment ->
Fire Handling Equipment and Systems
Fire Handling Equipment and Systems
(Showing headlines 121 - 140) 1 2 3 4 5 6 7 8 9
|
 Fire System Manager provides graphics-based monitoring.Silent Knight
Maple Grove, MN 55369 4927
Dec 30, 2004 With support for up to 16 nodes, IFP-Net Fire System Manager provides PC-based system that captures and displays fire events and conditions throughout facility via graphical display interface. Compatible with intelligent analog/addressable fire control panels IFP-1000 and IFP-100, it allows users to auto-navigate and locate device related to alarm or event based on priority of event. All components can be backed-up and stored in history manager. |
 Duct Smoke Sensors target HVAC applications.Honeywell Fire Group, Fire Control Instruments (FCI)
Westwood, MA 02090
Dec 17, 2004 Series ADP Low-Flow Photoelectronic Sensors detect smoke at air-speed velocities of 110–4,000 fpm, providing assistance in difficult smoke detection environments. Analog addressable units shut down fans, blowers, and air conditioning systems, preventing spread of toxic smoke and fire gases. Any sensitivity in sensors caused by dirt, temperature, or humidity is reported to panel, allowing compensation algorithms to maintain set sensitivity. |
Fire Suppression System provides 1,200 lb of agent.Siemens Industry, Inc., Building Technologies Division
Florham Park, NJ 07932
Dec 01, 2004
Agent Delivery Cylinder, Model FM-200R can provide 24 hr suppression protection for areas up to 40,000 cu-ft. During fire, system allows for maximum of 1,200 lb to be distributed through fixed piping network for protection of facility's most critical assets. Clean, colorless gas extinguishes fire in seconds and leaves no residue or damage.
|
 Fire Detection Products interface with existing units.NOTIFIER Fire Systems
Northford, CT 06472
Nov 17, 2004 Onyx Series includes Model 640 Fire Alarm Control Panel, ACPS Addressable Power Supply, XPIQ multi-channel audio transponder, RFX wireless detection systems, and Acclimateâ„¢ Plus detector. All have black patterned look, along with network, panel, and peripheral device designs. Units can be linked together to form integrated solutions for any life safety challenge. |
 Fume Hood Fire Suppression System activates instantly.Firetrace International
Scottsdale, AZ 85260
Nov 05, 2004 Fire suppression system provides fire protection at all major points of air flow inside fume cabinet. It features canister of fire suppression agent and flexible polymer detection tubing that can be routed anywhere inside cabinet. Upon exposure to 212°F flame, tubing ruptures and releases 1–50 lb of fire suppressant into fume hood. Self-contained system requires no electricity or external power, but can turn off power or signal alarm. |
 Pike Pole adapts to every situation.Akron Brass Co.
Wooster, OH 44691
Oct 08, 2004 Eliminating need to carry several different pike poles to fire ground, Adapt-a-Pole consists of one handle and various hooks for different purposes. User can change hooks by disengaging locking mechanism, then selecting and attaching desired hook for job. |
 Stream Foam Tube offers 2 methods of dispersion.Akron Brass Co.
Wooster, OH 44691
Oct 08, 2004 Style 3626 Master Stream Foam Tube features dispersion jaws and optional electric actuation. By flipping one switch, 800 gpm foam tube can be changed between straight stream and flat disperse spray stream. In addition, product includes manual override for changing streams if power is disrupted. It can be installed on Akron Brass StreamMaster Electric monitor for all-electric operation. |
 Pendent Sprinkler is suited for retail environments.Viking Corp., The
Hastings, MI 49058 9706
Oct 08, 2004
Suited for use in shopping malls and retail structures, K-14 Extended Coverage Ordinary Hazard (ECOH) sprinkler produces flows required to meet Ordinary Hazard density requirements at lower pressures than 8.0 or 11.2 K-factor sprinklers. UL and cUL Listed for coverage areas from 12 x 12 ft through 20 x 20 ft, sprinkler requires minimum spacing of 8 ft. When low-profile product is fully recessed, deflector is 1 1/8 in. from ceiling.
|
 Elastomeric Spray is used in firestopping and soundproofing.Acoustical Solutions, Inc.
Richmond, VA 23228
Oct 06, 2004
SpecSeal AS Spray provides spray-applied protection of joints and penetrations of all types. Professional-grade, latex-based acoustical coating suits construction joint applications such as floor-to-floor, floor-to-wall, wall-to-floor, wall-to-wall, and head-of-wall. Binder system is totally resistant to water and will not re-emulsify after drying. Clean-up is done via soap and water, and drying properties help avoid washouts.
|
 Upright Sprinkler features K-factor of 16.8.Viking Corp., The
Hastings, MI 49058 9706
Oct 04, 2004 Standard response storage sprinkler, Model K-17, provides densities of .45 or greater based on 100 sq ft spacing. Available in temperatures from 155–286°F, unit is qualified for use in protection of high-piled storage. It is UL and cUL listed for Light, Ordinary, or Extra-Hazard Occupancies for hydraulically calculated wet or dry systems per NFPA 13. |
 Fire Protection System provides pre-wired/piped solution.Tyco Engineered Products & Services
Exeter, NH 03833
Sep 10, 2004 MCC (Mist Control Center) AquaMist Delivery System is pump skid assembly with pump, controller, control valves, deluge valve, control panel, and system strainer. System also incorporates AquaMist® fire protection system, which uses mist application nozzles that produce reduced droplet sizes in discharge pattern. In fire condition, fine mist is transformed to steam, expanding each water droplet over 1,600 times its initial volume and displacing oxygen. |
 Fire Sprinkler protects combustible, concealed areas.Tyco Engineered Products & Services
Exeter, NH 03833
Sep 09, 2004 UL-listed CC2 Combustible Concealed Sprinkler provides protection of light-hazard combustible, as well as noncombustible, concealed spaces. Able to be used with wet- or dry-pipe sprinkler systems, upright sprinkler features 5.6 K-factor, 144 sq ft max coverage area, and 12 ft max spacing. Product meets NFPA® requirements and is suited for use in areas such as narrow attics and interstitial spaces between floors. |
 Domed Sprinkler targets residential fire protection market.Tyco Engineered Products & Services
Exeter, NH 03833
Sep 09, 2004 Concealed, pendent fire sprinkler, Model LFII features domed cover plate that eliminates necessity of drop-down sprinkler deflector and allows use of existing LFII Pendent sprinkler. Unit offers 4.9 K-factor, max coverage of 20 x 20 ft, and min flow of 13–21 gpm. Sprinkler is UL listed for installation in sloped and beamed ceilings, as well as with BlazeMaster® CPVC piping. Available in white and chrome finishes, cover plate provides ½ in. vertical adjustment. |
 Air Sampling Smoke Detector protects small, critical areas.Xtralis Inc.
Norwell, MA 02061
Jul 09, 2004
VESDA LaserFOCUS(TM) features SonicFlow(TM) ultrasonic flow sensing, circular display, and pre-engineered piping options. It provides tolerance to contamination, immunity to temperature changes and altitude, and absolute flow measurement in lpm. Dual-stage filter and clean air bleed-in help prevent contamination by dust and other air borne contaminants. Illuminated dial, LEDs, and related icons provide identification of smoke growth and alarm conditions.
|
 Analog Smoke Sensors feature low flow technology.Fire Control Instruments, Inc.
Waltham, MA 02451 1122
Jul 02, 2004 Series ADP Photoelectronic Air Duct Smoke Sensors detect smoke at air-speed velocities of 110–4,000 fpm. By sampling air currents passing through ducts, units shut down fans, blowers, and air conditioning systems, preventing spread of toxic smoke and fire gases. Series includes Model ADP non-relay, 2-wire device requiring signaling line circuit power only and Model ADP-R 4-wire, relay unit requiring signaling line circuit power and 24 Vac/dc or 120/240 Vac. |
 Fire Sprinkler works under horizontal and sloped ceilings.Victaulic
Easton, PA 18040
Jun 10, 2004 With 4–12 in. deflector to ceiling distance, Model V2738 Residential Horizontal Sidewall Sprinkler incorporates heat responsive, frangible glass bulb design and offers max spray coverage of up to 16 x 20 ft. It is available as quick response horizontal sidewall and recessed horizontal sidewall sprinkler in various finishes. Product can be used under smooth, flat, horizontal ceilings and sloped ceilings with up to 4/12 pitch. |
 Sprinkler offers fire protection in concealed spaces.Victaulic
Easton, PA 18040
Jun 10, 2004 Model V2502 Specific Application Sprinkler incorporates flat deflector to provide coverage of shallow areas between floor space and shallow, low-pitch attic spaces. With temperature rating of 175°F and natural brass finish, Model V2502 is UL Listed for use with wet or dry steel pipe systems, all CPVC UL Listed for fire protection, and in some cases, wet CPVC systems. Upright unit is intended for light-hazard combustible and non-combustible concealed spaces. |
Fire Alarm System offers distributed audio capabilities.Fire Control Instruments, Inc.
Waltham, MA 02451 1122
Jun 03, 2004 NetSOLO® Broadband delivers full-network control and communications, digital messaging, live voice instructions, and fire fighter telephone communications through distributed network fire alarm system, all on single pair of wires. It incorporates existing 7100 panels and can be expanded to meet growing application demands. System uses Boolean logic programming and Digital Signal Processor. |
Control Panel has remote programming/monitoring capabilities.Fire-Lite Alarms
Northford, CT 06472 1653
May 21, 2004 Manufactured with SMT, MS-9600 V2 addressable fire alarm control panel is offered with Digital Alarm Communicator Transmitter option that provides remote site upload/download and remote monitoring capabilities. It also lets technicians diagnose system problems remotely. Features include 14.4 kbaud modem, 2 Notification Appliance Circuits, and fire protection technologies such as Maintenance Alert, Automatic Detector Test, and Sensitivity Printout. |
 Flashlight features unbreakable ABS construction.Pelican Products, Inc.
Torrance, CA 90505
May 06, 2004 Available in alkaline and rechargeable models, Little Edâ„¢ right-angle, Xenon flashlight resists water and chemicals in hazardous locations. Stainless steel clip attaches unit to turnout coat or shirt pocket for hands-free use. Switch is easily operated, even with gloves. Available in black and yellow, flashlight includes safety lanyard and is suited for firefighters. |
(Showing headlines 121 - 140) 1 2 3 4 5 6 7 8 9
|
|
|