 Fire Protection System works even if all power sources fail.Viking Corp., The
Hastings, MI 49058 9706
Jul 26, 2002 SureFire™ non-cycling preaction system offers built-in features that ensure protection while preventing water from entering system. It operates as regular preaction system under normal conditions or as dry system if primary and backup power fail. Available with single- and double- interlock electric release in 1 1/2 to 8 in. sizes, SureFire consists of angle-pattern or straight-through Deluge Valves, EZ Trim, Easy Riser™ check valve, and Par-3 Release Control Panel. |
 Upright Sprinkler features K-factor of 16.8.Central Automatic Sprinkler Co.
Lansdale, PA 19446
Jul 16, 2002 Model ESFR-17 Early Suppression Fast Response Sprinkler can be used in storage buildings up to 35 ft high with 30 ft of storage. It may be installed on branch-line piping up to 3 in. without sprigs. Sprinkler offers end-head pressure savings from 15 to 23 psi compared to K14 ESFR, and eliminates requirement for in-rack sprinklers. |
 Fire Suppression System continuously protects heavy equipment.Firetrace International
Scottsdale, AZ 85260
Jul 08, 2002 Fire Suppression System is fully operational without electricity or external power source. Designed to instantly detect and extinguish open flame at source, system is totally self-contained and dispenses suppression agent to extinguish fire. Flexible polymer tubing ruptures when exposed to open flame. System is available with cylinders containing various suppression agents including FM-200®, CO2, dry chemical powders, and foam. |
 Check Valves are UL listed and FM approved.Viking Corp., The
Hastings, MI 49058 9706
Jun 11, 2002
Check Valves, in 1½ and 2 in. sizes, can be installed horizontally or vertically. They are rated up to 250 psi water working pressure and include tapped opening for system draining. Both 1½ in. and 2 in. are UL and ULC listed in threaded or grooved styles, and are FM approved in the grooved configuration as both single check valves and anti-water hammer check valves.
|
 Fire Extinguisher protects electrical apparatus.Firetrace International
Scottsdale, AZ 85260
May 17, 2002 Electrical Fire Suppression System can detect fire inside enclosure and instantly release clean suppression agent to minimize damage to components and circuitry. It works inside mission-critical electrical enclosures and control panels such as PLCs, MCCs, and switch gear. Flexible polymer tubing that ruptures when exposed to flame can be routed anywhere within cabinet to automatically dispense suppression agent to extinguish fire. |
Module centrally monitors fire-alarm control panels.Keltron Corp.
Waltham, MA 02154
May 10, 2002 Model 95M3222 Datatap (TAP) module accepts RS232 data from serial data sources such as printer ports and intelligent Fire Alarm Control Panels (FACPs). Once connected, Datatap utilizes RF750F Radio Subscriber Unit to send data through wireless network. It provides one RS232 output port, and utilizes jumpers to select appropriate personality-matched software for interfacing. Datatap emulates digital communicator by converting RS232 data to Contact-ID. |
 Smoke Detector provides early fire warning.Fenwal
Ashland, MA 01721
Mar 21, 2002 AnaLASER(R) II air-sampling smoke detector actively draws air from protected space and analyzes it for smoke presence. Utilizing Laser Particle Counting detection technology, it detects smoke while electronically ignoring particles that are not same size as smoke. AnaLASER II offers programmable sensitivity range; 2 programmable alarms and 2 pre-alarm levels; networking of up to 127 detectors; 28-day history buffer; and communications software. |
 Smoke Detector works in hostile environments.NOTIFIER Fire Systems
Northford, CT 06472
Mar 05, 2002 HARSH(TM) provides smoke detection in dirty and wet surroundings. It eliminates nuisance alarms by using small air intake fan to draw air and smoke into photoelectric sensing chamber. Micro-pore filter removes unwanted airborne particulates and water mist, while its housing protects detection chamber and electronics. Features include two 25 Micron filters, intelligent analog communication for fan supervision, and cycled fan operation. |
 Fire Suppression Systems protect without electricity.Firetrace International
Scottsdale, AZ 85260
Feb 27, 2002 Self-contained Automatic Fire Suppression Systems instantly detect and extinguish fire inside equipment, enclosed spaces, or cabinets up to 250 cu ft. They incorporate flexible, polymer tubing that ruptures and dispenses customer-selected suppression agent when it is exposed to flame. FM-200® or CO2 clean agents are non-conductive and leave no residue. Dry powders and foams are used for fuel sources or exposed flammable liquids. |
 Mobile Firefighting Rig uses halotron instead of halon.Fire Combat (A Div. Of Sensor Electronics Corp.)
Marinette, WI 54143
Feb 27, 2002 Mounted on pickup bed or trailer, Halotron/I can be quickly moved to quench fires. It can also be mounted on skid to give on-site protection for aircraft hangars, offshore platforms, turbine/generator sets, and transformer vaults. Rig has 300 cu. ft cylinder carrying compressed argon and 460 lb Halotron-filled tank. In operation, pressurized argon spews out Halotron at 225 psi, effectively smothering fire. It meets EPA and FAA requirements. |
 Suppression System stops flash- fires inside CNC machines.Firetrace International
Scottsdale, AZ 85260
Jan 02, 2002 Automatic Fire Suppression System features flexible polymer tubing which ruptures when exposed to 212°F, and automatically activates system to instantly dispense suppression agent. It detects and extinguishes fires inside CNC machines by flooding workpan and turning power off. Unit is totally self-contained and requires no electricity or external power. Tubing can discharge CO2, FM-200, dry chemical powders or foam. |
 Fast Smoke Detector provides early warning.NOTIFIER Fire Systems
Northford, CT 06472
Dec 21, 2001 Acclimate Plus scans 10 devices simultaneously, so it constantly monitors temperature, smoke, electrical noise and air particulate levels. It can report alarm within 1 sec and turn on all outputs within 2 sec. Dual-stage drift compensation reduces maintenance by notifying control panel when dust buildup requires attention. Its smoke detection sensitivity increases with heat, eliminating need to set sensitivity levels at panel.
|
 Dry Pipe Valve controls firefighting water.Central Automatic Sprinkler Co.
Lansdale, PA 19446
Nov 16, 2001 Model DPV-1 differential valve automatically controls flow of water into dry pipe fire protection sprinkler system upon operation of one or more automatic sprinklers. It has external reset and does not require priming water, thereby simplifying resetting procedure. Its galvanized valve trim is shipped in partially assembled components, reducing installation time. Valve is available in flange and groove versions in 4 and 6 in. sizes.
|