|
|
Advertisement
|
|
Plant Furnishings & Accessories ->
Equipment Enclosures
Equipment Enclosures
(Showing headlines 61 - 80) 1 2 3 4 5 6 7 8 9
|
Injection Molded Case has durable, lighter-weight design.Underwater Kinetics
Poway, CA 92064
Aug 22, 2006
Comprised of 12 models, impact-resistant LoadoutCase(TM) series is based on UKtekmat 2.0(TM) polypropylene resin blend and protects OEM, military, and consumer products during travel and storage. Hollow core silicone rubber O-ring is used for main seal against humidity, water, and dust as well as corrosive gases, while pressure equalization is controlled by screw down valve. Waterproof up to 1 m, unit features rib-reinforced walls and stainless steel twist-lock latches.
|
 Customizable Enclosures meet packaging industry needs.AD Products Co.
Cleveland, OH 44135
Jul 13, 2006
Suited for packaging and processing industries, custom enclosures are built to specific requirements and come in sizes from 16 x 16 x 6 in. to 30 x 24 x 24 in. Each offers ability to add holes, cut-outs, drip panels, lighting kits, fans, and other options. Composed of all stainless steel hardware, enclosures arrive ready to install and come in various UL-listed options. NSF-certified model is available for food, chemical, and pharmaceutical packaging industries.
|
 Pushbutton Enclosures are offered in 30.5 mm version.Rockwell Automation
Milwaukee, WI 53204
Jul 05, 2006
Series 800H pushbutton plastic enclosures are designed for applications requiring e-stop with yellow background or those requiring increased visibility of pushbutton station. UL and CSA rated, enclosures have thermoplastic polyester blend construction that provides impact resistance and are available with 1-, 2-, 3- and 4-hold configurations in cover-to-base orientation. Enclosures are designed for commercial, OEM, and light industrial applications.
|
 Chassis features 12 slots for AMC modules.Elma Electronic Inc.
Fremont, CA 94538
Jun 29, 2006
Targeted for storage arrays, firewalls, blade servers, and home entertainment centers, MicroTCA systems support up to 48 single width, half height AdvancedMC modules. MicroTCA chassis 4U subrack features front-to-rear cooling and 14-slot Single Star backplane. Compliant to MicroTCA.0 v1.0 specification, subrack contains 1 MicroTCA Carrier Hub and 1 power module. EMC shielding and airflow are controlled by honeycomb filter structures.
|
 Sheet Metal Enclosures enable 100% space utilization.Buckeye ShapeForm
Columbus, OH 43207
Jun 21, 2006
Featuring double-wall steel and aluminum construction, VersaFlex Series Desktop/Rack Mount Enclosures allow mounting of heavy components. They are designed with round edges, 2-tone colors, and concealed mounting screws. Units are available with assortment of accessories including different trims, handles, feet, and shielding upgrades.
|
 Sealed Enclosure meets requirements of buried applications.Corning Cable Systems
Hickory, NC 28603-0489
Jun 14, 2006
Providing environmental protection, OptiTect(TM) Premier Sealed Local Convergence Point Enclosure allows centralized splitting architectures to distribute up to 144 fibers in sealed environment. It holds up to five 1 x 32 splitter modules with pre-terminated SC UPC or APC adapters. Unit is prestubbed with 100-ft 12-fiber feeder cable terminated inside enclosure to splitter input connector panel, and with 100-ft 144-fiber distribution cable terminated on distribution side of connector field.
|
 Plastic Enclosures house switches, controls, and alarms.Bud Industries, Inc.
Willoughby, OH 44094
May 30, 2006
Measuring 6.10 x 4.60 x 1.37 in., Utilibox Style A Enclosures feature internal dimensions of 5.84 x 4.34 x 1.17 in. They come in flanged and unflanged styles, weighing 6.3 oz and 5.9 oz, respectively. Bodies and covers are UL94-5VA rated ABS with textured surfaces for mar resistance. All enclosures have PCB mounting bosses and are available with or without molded-in wall mounting brackets.
|
 Die-Cast Aluminum Enclosures are NEMA-rated.Bud Industries, Inc.
Willoughby, OH 44094
May 23, 2006
Featuring one-piece molded construction, Series CN includes flanged versions in 10 sizes from 3.52 x 1.38 x 1.22 in. to 8.75 x 5.74 x 2.25 in. and un-flanged models in 15 sizes from 2.36 x 2.16 x 1.22 in. to 10.81 x 6.89 x 2.64 in. Optional mounting flanges are molded to base of enclosure, allowing units to be opened without need to detach them from wall. Enclosures are suited for instrument cases, meter cases, and junction boxes in wet and dirty, marine, and washdown environments.
|
 Watertight Case offers more than 2,000 cu-in. storage space.Pelican Products, Inc.
Torrance, CA 90505
May 02, 2006
Featuring top loading design, Protector(TM) 1440 Case is equipped with stainless steel, ball bearing, polyurethane wheels; telescoping, metal handle; rubberized top and side grips; and stainless steel reinforced padlock protectors for added defense against cutting and theft. Lid has polymer O-ring for dust and waterproof seal, while automatic Gore-TEX® pressure equalization valve stops moisture from entering case and prevents vacuum-lock so case opens at any altitude.
|
 Explosionproof Enclosure houses WLAN access points.Adalet Wireless
Cleveland, OH 44135
Apr 26, 2006
Consisting of 2 wireless AW-CTB-2400 Div 1 antennas mounted on explosionproof enclosure, Model AW-XAP is suited for WLAN access points, routers, and bridges to extend 802.11 b/g network coverage into hazardous locations. Second version utilizing wireless glass radome allows mounting of stock whip antennas within protection of domed glass design. Enclosure systems carry 3rd party approvals from UL as well as ATEX certification when specified.
|
 Stainless Steel Enclosures target industrial applications.Carlo GAVAZZI Automation Components
Buffalo Grove, IL 60089
Apr 18, 2006
Offered in 304 SS with 316 SS as option, Series STX includes IP65/NEMA 12/4/4X rated models from 12 x 8 x 6 in. to 47 x 31 x 12 in. and IP55/NEMA 12 double-door versions up to 31 x 47 x 12 in. All are provided with back plate, locking system, and mounting accessories. Other IP55/NEMA 12 models include ARETA modular cabinets with or without plexiglass doors, cabinets with pull-out keyboard, freestanding ATB8 cabinets, and IP65/NEMA 4 terminal boxes.
|
Arc Flash Safety System addresses NFPA compliance.Hoffman
Anoka, MN 55303 1778
Mar 31, 2006
Comprised of INTERSAFE(TM) Data Interface Ports, window kits, folding shelves, CONCEPT® Keyboard Box, and external data pockets, Arc Flash Safety System provides safe exterior access to controls, protecting workers against arc flash explosions. Data Interface Ports provide data access without opening enclosure doors. Connectors interface with all major data and industrial communication protocols and either breaker-protected GFCI or standard duplex outlet.
|
 Enclosures feature integral mounting flange.Stahlin Enclosures
Belding, MI 48809
Mar 28, 2006
FATBOY Double Deep J Series of Enclosures features clam shell appearance, and is available in 11 sizes from 6 x 4 x 8 in. up to 20 x 16 x 17 in. with 21 configurations. Units are formulated from SolarGuard(TM) fiberglass material that ensures UV resistance. Enclosures incorporate SS latches and hinges, back panel mounts on both cover and base, and urethane gasketing. They are UL/CSA rated to Type 12, 3R, and 4X as well as IEC 60529 IP66 for protection against extreme environmental conditions.
|
 Junction Box suits explosion-proof applications.Thomas & Betts Corp.
Memphis, TN 38125
Mar 23, 2006
Measuring 4 x 4 in., GUP Explosion-Proof Enclosure is available in 2 configurations. Model GUP214-TB features ten ¾-in. NPT hubs with 7 conduit plugs, and Model GUP215-TB features six ¾-in. NPT hubs with 3 conduit plugs. Both have 2 hubs on top and bottom, and 1 hub on each side. Body is constructed of electro-galvanized ductile iron finished in aluminum acrylic paint, and cover is copper-free A6 aluminum. Neoprene O-ring gasket makes unit rain-tight.
|
 Enclosures suit AdvancedTCA blade and server applications.Elma Bustronic
Fremont, CA 94538
Mar 13, 2006
Optima AT Series of vertical rack enclosures measure 44U high x 600 mm wide x 600 mm deep for mounting up to three 14U ATCA chassis. Cabinets feature integrated air baffling to ensure cooling path integrity, 4 high volume CFM fans, and top cabinet exhaust. Cable management is configurable for horizontal and vertical chassis mounting, and cabinet door is gasketed for environmental sealing. Modular base allows for fixed mount, leveler, or caster options.
|
 Enclosures suit ATCA format blade/server applications.Optima Electronic Packaging Systems
Tucker, GA 30084 5088
Feb 28, 2006
AT Series of vertical rack enclosures measures 44U x 600 mm x 600 mm and features integrated air baffling, 4 CFM fans, top cabinet exhaust, and mounting for up to three 14U ATCA chassis. Cable management is configurable for horizontal and vertical chassis mounting with FO router. It offers top front/rear cable access panels, and optional 1U cable trough for mounting between sub-racks. Cabinet also features 4-point latching handle system, removable side panels, and gasketed door.
|
Enclosures house molded case circuit breakers.Schneider Electric
Palatine, IL 60067-7399
Feb 15, 2006
Suited for commercial and industrial uses, PowerPact® H- and J-frame Enclosures give contractors options for 15-250 A applications where branch circuit disconnect with circuit protection is required. NEMA Type 12 and corrosion-resistant Type 4 models prevent ingress of contaminants from surrounding environment. Versions are also offered for NEMA Type 1 flush- and surface-mounted indoor applications and NEMA Type 3R outdoor applications.
|
 Enclosures isolate lab automation equipment.HEMCO Corp.
Independence, MO 64056
Jan 30, 2006
Custom modular EnviroMax laboratory and robotic process enclosures are engineered to maintain either vented exhaust air, HEPA filtered supply air, bi-containment enclosures, or temperature controlled re-circulating air. Various accessories, including support tables, work surfaces, lighting, electrical, plumbing, and glove ports are available for applications such as isolating liquid handling workstations or HPLC equipment sample weighing.
|
 Drive Enclosure suits commercial HVAC applications.Yaskawa Electric America
New Berlin, WI 53151
Jan 26, 2006
Configured for E7 variable frequency drive, NEMA 3R rated enclosure protects against rain, snow, sleet, and airborne dust particles as small as 10 microns in size. Carrying UL Type 3R label, it features locking door, force ventilation, door mounted drive operator keypad, and dual current rating on data nameplate for 40 and 50°C ambient operating temperature. Enclosure can also be configured for P7, F7 and G7 drives.
|
Liquid-Cooled ATR Chassis cools up to 100 W per slot.Hybricon Corp.
Ayer, MA 01432
Jan 26, 2006
Designed for applications using high-power, conduction-cooled boards, 1-ATR chassis meets ARINC 404A/MIL-STD-91403 requirements and features brazed construction with liquid-cooled card cage sidewalls. Top load 1 ATR short is available in standard and high-power configurations with 9- or 8-slot VITA 41 VXS or VME64x backplane and 1 or 2 power supplies, respectively. High-power configuration is capable of 800 W for 1 ATR short or 1,000+ W for 1 ATR long.
|
(Showing headlines 61 - 80) 1 2 3 4 5 6 7 8 9
|
|
|