|
|
Advertisement
|
|
Plant Furnishings & Accessories ->
Equipment Enclosures
Equipment Enclosures
(Showing headlines 21 - 40) 1 2 3 4 5 6 7 8
|
 Industrial Enclosures promote reliable networking.Rittal Corporation
Springfield, OH 45504
Nov 19, 2007
Housing sensitive networking equipment in plant floor environments, enclosures can be individually configured to suit specific requirements with range of accessories. They are available in carbon steel wallmount and freestanding designs to promote manufacturing environment networking efficiency and security monitoring capabilities. Available products include RiLAN junction boxes and RiLAN bus enclosures, each of which is offered in various versions.
|
 Camera Enclosure is effective down to -40°F.Dotworkz Systems, Inc.
San Diego, CA 92110
Nov 19, 2007
Model D2-XC is equipped with Ring of Fire(TM) heating system, which provides constant warm airflow and built-in defrosting. Compatible with most analog and PTZ surveillance cameras, enclosure offers on-board mounting space that accommodates routers, cell networks, hard drives, UPS, WiMAX, and Mesh hardware. Rapid Link(TM) allows integration into 900, 5.8, and 2.4 GHz wireless networks worldwide with range of up to 20 miles.
|
 Rack Mount Chassis suits general purpose applications.Advantech Automation Corp.
Cincinnati, OH 45240
Oct 18, 2007
Featuring 4 status LEDs, IPC-630 supports PICMG 1.0/1.3 backplanes of up to 15 slots and ATX motherboards. This 4U rack-mount chassis offers front access to removable fans, including filters made of washable nylon material. Behind lockable front door, unit provides access to I/O port connectors and disk drives. Shock-mounted, removable disk drive carrier provides three 5.25 in. and one 3.5 in. drive bays as well as one 3.5 in. internal drive bay.
|
CompactPCI Enclosure has environmentally sealed design.Aitech Defense Systems Inc.
Chatsworth, CA 91311
Oct 18, 2007
Lightweight E192 2-slot 3U cPCI enclosure incorporates modular and removable power supply and houses standard ANSI/IEEE 30.1-2002 conduction-cooled cPCI and PMC modules. Baseplate allows dissipation of over 50 W at 160°F while maintaining 25.2°F difference at card edge. It also features 28 Vdc power input per MIL-STD-704 with EMI/EMC-compliant power input filter and backplane I/O transition module to support front panels designed for circular MIL-C-38999 or other connectors.
|
Rugged Card Cage Enclosures withstand caustic environments.Carlo Gavazzi Computing Solutions
Brockton, MA 02301
Sep 07, 2007
Measuring 8U to 15U high and 20.5 in. deep, Series 709 air-cooled electronic enclosures accommodate up to 20 slots for VME64, VME64x, VXS, VPX, VXI, or CompactPCI cards. Available in ac/dc or multiple-output power configurations of up to 2,000 W, cooling system can also be configured in pressurized, evacuation, or combination push/pull ways. Featuring either overlapping bolted or welded construction, EIA rackmountable series can withstand severe shock and vibration.
|
Custom Electrical Enclosures exhibit chemical resistance.Fibox Enclosures
Glen Burnie, MD 21061
Sep 04, 2007
Made from injection molded polycarbonate, ARCA enclosures are available in interior sizes ranging from 6.00 x 6.00 x 4.00 in. up to 14.00 x 12.00 x 7.00 in. NEMA 4X rated enclosures come with screw cover, hinged screw cover, or hinged enclosure with several latch options. Covers feature overlapping design that protects formed-in-place polyurethane gasket. Mounting plates and fixed and hinged inner panels are offered in metal/non-metallic versions.
|
 Rackmount Enclosure is designed for high-availability.Chassis Plans Inc.
San Diego, CA 92123
Aug 21, 2007
Mission-critical-qualified 2U E9Chassis provides 4 hot swap drive bays for 3½ in. SATA, SCSI, or EIDE drives, allowing RAID implementation. Dual 5¼ in. drive bays enable installation of DVD and tape drives, one 3½ in. drive position provides for floppy drive installation, and one 3½ in. drive can be used for sensitive crypto data or OS. Chassis can accommodate 3 horizontally mounted full-length, full-height plug-in cards or 7 vertically mounted low-profile plug-in cards.
|
Rack Enclosure features integrated cooling capabilities.Emerson Network Power
St. Louis, MO 63136
Jul 16, 2007
Suited for small and mid-size data centers, Liebert XDK-W features nominal rating of 25 kW. Closed architecture solution utilizes air circulation internal to enclosure that is completely sealed from room air and environmental conditions. Server heat load is absorbed by rack's integrated cold water system through air-to-water heat exchanger in bottom of rack, while coolant distribution unit maintains fluid temperature above actual dew point to prevent condensation.
|
Enclosure is designed for washdown areas.Safety Technology International
Waterford, MI 48327
Jul 09, 2007
Able to help prevent false fire alarms, surface-mount Stopper® II has 4 in. deep enclosed backbox that allows unit to be installed in washdown areas while also protecting against physical damage, dirt, and grime. Enclosure, with NEMA 3R-rated cover (STI-1200A), consists of clear, tamperproof, polycarbonate shield and backbox that most manual pull stations and addressable modules can fit into.
|
Outdoor Enclosures use Lexan sheet in solar shields.Alcatel-Lucent
Paris 75008 France
Jun 29, 2007
Measuring 6 x 3 x 2.5 ft, Modcell outdoor enclosures house cellular equipment for service providers. Use of GE Plastics' matte-textured Lexan 9000 polycarbonate (PC) sheet with molded-in color in solar shields provides resistance to impact down to -40°F as well as flame and shotgun blasts. Weatherable Lexan PC sheet withstands outdoor environments and complies with requirements of Telcordia GR 489 standard. Fully recyclable sheet requires no welding and is non-brominated.
|
MicroTCA Shelf measures 1U high.Elma Electronic Inc.
Fremont, CA 94538
Jun 26, 2007
MicroBox(TM) features up to 10 mid-size, single width modules and measures 45 x 465 x 210 mm. Five module bays can be filled with range of module configurations in single or double modules or full, mid, or compact sizes. Side-to-side cooling configuration has no bends in airflow path and it dissipates 35 W per module with use of 8 fans providing 20 cfm each. Backplane features slots for 6 AMC, 1 power module, 1 MCH, 1 JSM, and connections to 2 cooling units.
|
Custom Enclosures suit wet, dry, and corrosive environments.Bud Industries, Inc.
Willoughby, OH 44094
Jun 12, 2007
BT Series enables users to see inside box from every direction and inspect for moisture and read indicators without opening seal, which provides environmental protection of electronic components. Available in 7 sizes ranging from 4.53 x 3.54 x 2.17 in. to 11.81 x 9.06 x 3.39 in., they meet NEMA 1, 2, 4, 4X, 12, 13 IEC52/IP65, and UL508-4X specifications. Made of transparent plastic with blue tint, units include wall mounting holes, cover attaching screws, and internal guide slots.
|
NEMA Rated Enclosures are totally transparant.Bud Industries, Inc.
Willoughby, OH 44094
Jun 01, 2007
Suited for wet, dry, and corrosive environments, BT Series allows users to see inside from every direction, inspect for moisture, and read indicators without opening seal. Available in 7 sizes ranging from 4.53 x 3.54 x 2.17 in. to 11.81 x 9.06 x 3.39 in., they feature wall mounting holes, cover attaching screws, and internal guide slots. Enclosures are made of transparent plastic with blue tint, and meet NEMA 1, 2, 4, 4X, 12, and 13 IEC52/IP65, and UL508-4X specifications.
|
 Racks are available from 22-47U and 600-800 mm.Hewlett Packard
Houston, TX 77269-2000
May 30, 2007
HP 10000 G2 Series Racks feature multi-angle door design and fully perforated front and rear doors providing cooling and ventilation. Steel of 7x2 roll frame is folded 7 times, enabling racks to hold net weight of 2,000 lb of static and dynamic loading. Holes in 4 mounting rails allow side-to-side cabling, and for high density environments, units feature cable egresses on top, removable access panel on rear door, and cable management straps.
|
 Wall-Mount Enclosure accommodates 1/8 DIN instruments.Laurel Electronics, Inc.
Costa Mesa, CA 92626
May 30, 2007
Offering environmental protection to NEMA-4X, Model BOX wall- or bulkhead-mount enclosure comes with 1/8 DIN panel cutout for use with 1/8 DIN instruments with 5.30 in. max depth. Compartment that houses instrument is hermetically sealed, and mounting holes are located on rear surface, outside of sealed compartment. Wire feedthroughs are via 3 sealed cable glands, which accept up to 0.24 in. dia cables. Transparent cover is available for instruments lacking front-panel protection.
|
Rack Enclosure features integrated cooling capabilities.Emerson Network Power
St. Louis, MO 63136
Apr 26, 2007
Utilizing water to dissipate heat out of enclosure, Liebert XDK 19 in. rack enclosure provides cooling for up to 17 kW of high-density electronics. Coolant distribution unit helps maintain fluid temperature above dew point to prevent condensation on piping, coils, and walls, while integrated cold water system absorbs server heat load through air-to-water heat exchanger. Unit facilitates blade server and other high density heat load computing equipment deployment.
|
 CompactPCI/VME Enclosures have front-pluggable design.Carlo Gavazzi Computing Solutions
Brockton, MA 02301
Mar 23, 2007
Suited for industrial and telecom computing systems, 500 Series enclosures are engineered as turnkey systems with backplane, power, and cooling components that promote end-user customization. Products are designed for development, testing, and measurement purposes. With open architecture that facilitates service, series is configured with front and rear ground studs as well as ESD jacks and meets VITA and PICMG backplane specifications. Models range from 200-1,200 W.
|
Protective Cabinet includes air conditioning unit.Safety Technology International
Waterford, MI 48327
Mar 21, 2007
Featuring metal construction, Model STI-7560AC protects outdoor-rated fire alarm control panels from extreme temperatures, vandalism, dirt, dust, and grime. Clear window allows unit within to be seen and quickly identified. To help maintain correct range of operating temperatures, AC unit cycles as required and fan runs continuously to sustain uniform temperature inside enclosure. Designed to mount on wall, enclosure protects units up to 36 x 24 x 8.92 in.
|
Temperature Control Enclosures protect wide range of devices.Safety Technology International, Inc.
Waterford, MI 48327
Feb 23, 2007
Heated Polycarbonate Enclosures shield keypads, annunciators, and other electronic products from vandalism, accidental damage, as well as weather, dirt, dust, and grime. Units are designed to maintain temperature above freezing and offer choice of 12, 16.5, or 24 V with 3 thermostats. Featuring 5.5 x 7.5 in. internal clearance, they come with external thumb lock or key lock and offer 2 enclosed backboxes with 4.25 and 2.0 in. depth, respectively.
|
Safety Cell Enclosure includes air filtration.Frommelt Safety Products
Milwaukee, WI 53224
Feb 07, 2007
Enviro Saf-T-Cell(TM) protects employees and neighboring machinery from flying debris, weld flash, machine noise, and toxic fumes. It features 8-gauge, powder-coated steel fencing and post system; translucent or opaque fabric panels; and Guardian(TM) automated roll-up door with Category 4 non-contact interlock switch relay. Enclosure is UL approved, meets NFPA-701 flame propagation requirements, and complies with ANSI/RIA-1506 barrier standards.
|
(Showing headlines 21 - 40) 1 2 3 4 5 6 7 8
|
|
|