|
|
|
Plant Furnishings & Accessories ->
Equipment Covers
Equipment Covers
(Showing headlines 41 - 54) 1 2 3
|
 Air Outlets blend with virtually any decor.SpacePak
Westfield, MA 01085
Aug 18, 2004 Architectural Outlets offer optional replacement for standard white plastic air outlets, and can be located on walls, floor, or ceilings. All round metal outlets are 5 in. dia and come in white, gray, black cast aluminum, or cast brass. Natural wood outlets are available in surface mount or flush mount configurations, with and without louvers, and in choice of oak or maple. Victorian outlet covers are 6 5/8 in. dia, and available in white or variety of finishes. |
 Protective Panel extends life of dock seals.Rite-Hite Corp.
Milwaukee, WI 53224
Apr 29, 2003
HeatShield(TM) Protector Panel prevents burn damage from heat of swing-out dock lights. Multi-layer matrix of insulating and heat-transferring materials keeps dock seal component temperatures to safe level. Outer cover is high-temperature-resistant fabric that protects panel against scuffs and scrapes. Pliable internal components allow panel to bend and be flattened as needed. HeatShield Panel mounts directly on dock seal or shelter it is protecting.
|
 Venting Covers safeguard personnel and equipment.VISTAS Corporation
North Huntingdon, PA 15642
Feb 04, 2003 RadVentLoc™ Covers install on hand holes and inspection ports of secondary-side steam generators during outage service. Model RVL-60 is for 6.0 in. hand holes while Model RVL-27 is for 2.4 in. inspection ports. Two-layer design reduces millirem emissions and meets FME standards. Close-mesh stainless steel screen deflects external debris without impeding airflow, and 2 in. thick lead shield with diagonal channels absorbs and disperses gamma rays, all while maintaining ventilation. |
Protective Cover suits NEMA starters and contactors.Rockwell Automation
Milwaukee, WI 53204
Feb 04, 2003
Protective cover helps prevent accidental contact with current-carrying components such as line and load side terminals, coil terminals, and single-block auxiliary contacts. Flexible design allows users to retrofit installed contactors and starters and does not compromise accessibility, allowing users access to terminal screws or lugs for wiring, continuity testing, and maintenance. Installation can occur without removing existing wiring.
|
 Protective Case for mounting Temp/RH data logger.Onset Computer Corp.
Bourne, MA 02532
Dec 19, 2002 Tested to NEMA 4X standards, case mounts HOBO LCD Temp/RH Data Logger in condensing, wet, or dusty environments. It protects against corrosion, wind-blown dust and rain, splashing, and hose-directed water. Sensor cable feeds from LCD Logger through watertight grommet to external sensor. Made of UV-stabilized polycarbonate, product contains removable cap with O-ring seal and internal desiccant pack to minimize internal condensation. |
 Fabric Covers fit tote bins and hoppersAmerican Fabric Filter Co.
Wesley Chapel, FL 33543
Jul 03, 2002 Tote bin and hopper covers have stainless steel rods sewn into fabric along the top to keep covers rigid and prevent them from sagging down into hopper. |
 Weatherproof Covers meet National Electrical Code requirements.Thomas & Betts Corp.
Memphis, TN 38125
Jun 11, 2002
Steel City? Outdoor while-in-use and Red-Dot Codekeeper? in-use covers meet 2002 NEC Code 406.8(B) for outdoor weatherproof applications. Steel City cover comes with clear Lexan? cover, allowing unobstructed view of device. Key-lock version is also available. Red-Dot Codekeeper cover is die-cast aluminum with integral locking tab. Both are UL-listed and CSA approved and are available in single and two gang covers.
|
 Cover Assembly eliminates leaks in pump controllers.Minnesota Rubber & QMR Plastics
Minneapolis, MN 55416
May 29, 2002 Cover Assembly consists of integral control lever, actuating spring, and elastomer face seal. Its design materials handle effects of dampening fluid under pressure and withstand varying humidity and temperature changes. Assembly mounts face seal down to pressure control pilot valve with electrical connections made through round opening in cover wall. Assembly is suitable for use in off-highway equipment such as curb formers and skid steerers. |
 Nylon Covers protect all types of linear rails.A & A Mfg. Co., Inc.
New Berlin, WI 53151
May 14, 2002 Neoprene-coated, nylon Gortite(R) bellows-type covers are designed to protect linear motion systems from contaminants in all types of industrial environments. They are available for light, medium, and heavy duty applications in custom and stock sizes. |
 Cover Strips protect miniature ball rail systems.Bosch/Rexroth Corporation
Hoffman Estates, IL 60192
Mar 28, 2002 Stainless-steel cover strips are pre-cut to rail length and cover mounting holes in profiled rail, eliminating plastic mounting hole plugs. They protect against dirt and contaminants, and provide unbroken rail surface to improve runner block sealing. Miniature Ball Rail Systems include sizes 7, 9, 12, 15 and 20 mm and wide version in sizes 9, 12 and 15 mm. Cover strips can be supplied in one piece up to 1,000 mm, and fit all sizes except 7. |
 Lift Cover protects people and mechanisms.A & A Mfg. Co., Inc.
New Berlin, WI 53151
Mar 27, 2002 Duratite(TM) lift cover protects lift mechanisms and personnel from dust, dirt, foreign objects and pinch points. Its four rigid sides are made without stitching or adding metal wires, providing easy cleaning, ease of attachment and resistance to wear. Cover has reinforced ends, vents for uniform air flow during operation, and tie strips to allow proper expansion and retraction. Lift covers are available in black or combination of black and yellow.
|
 Hand Wheel Cover prevents ice build-up.Draeger Safety, Inc.
Pittsburgh, PA 15230
Mar 14, 2002 Easy Grip silicone hand wheel cover fits over first stage reducer hand wheel on SCBA. It insulates aluminum hand wheel preventing cylinder and hand wheel threads from bonding together. Cover prevents water and ice from entering cylinder/reducer connection while allowing thin layers of ice to be removed by squeezing. Easy Grip fits high and low pressure SCBAs and prevents over tightening of hand wheel. |
 Folded Covers protect equipment.Gagne, Inc.
Johnson City, NY 13790 0487
Dec 03, 2001 Folded covers are available in wide range of materials to suit environment, from light duty dust to harsh abrasives. They have internal support system consisting of stiffeners or ribs made from rigid PVC and die cut to fit guide configurations of equipment to be protected. Folded bellows have maximum open-to-close ratio, useful in limited space. Mounting end plates can be engineered and incorporated into design.
|
 Solder Covers protect CompactPCI boards.Bivar, Inc.
Irvine, CA 92618 2593
Nov 08, 2001 SSC Solder Side Covers Series eliminate ESD and shorting problems associated with hot swappable 6U and 3U PCBs and peripherals. Covers protect solder side of PCBs with transparent puncture-resistant barrier. Made with ESD dissipative Mirrex 7002 certified PVC film, covers meet Bell Core GR-1421-CORE, EIA 541 and MIL-PRF-81705D specifications. Covers mount onto existing PCBs by using four small screws or plastic snap-rivets at corners of PCB. |
(Showing headlines 41 - 54) 1 2 3
|
|
|
|
 |
ThomasNet News Advertisers
|
 |
|