|
|
Advertisement
|
|
Optics & Photonics ->
Other
Other
(Showing headlines 21 - 40) 1 2 3
|
 Sorter offers laser-sensing technology.Key Technology, Inc.
Walla Walla, WA 99362
Jan 19, 2006
Optyx® 3000 Series sorter suits packaging lines handling up to 6 tons of product per hour. As Class I laser sorter, Optyx® 3000 maximizes simultaneous detection and removal of defects and foreign material. Using high intensity discharge illumination system and CCD-based camera, sorter analyzes size, shape, and subtle color differences. Compact, self-contained unit connects to air, power, and water within processing line.
|
 Upgrade Package supports optical sorting systems.Key Technology, Inc.
Walla Walla, WA 99362
Nov 29, 2005
Suited for updating electronics and optics in Key legacy sorters up to 20 years old, G6 Upgrade Package includes advanced vision engine, color and VIS/IR cameras, as well as CameraLink, FireWire, and Ethernet broadband connectivity standards. Image Processing Module features FPGA chipset, which puts power of entire electronic rack in single chip. GUI resides locally on system's controller but can also be accessed remotely via network or Internet.
|
Crystal Quartz Waveplates provide polarization control.Meller Optics, Inc.
Providence, RI 02940
Jun 02, 2005
Measuring 75-150 µm thick, Crystal Quartz Waveplates are polished to precise finish and ±0.3 µm thickness tolerance. They can be supplied with V coat or broadband A/R coatings of less than or equal to 0.25% R per surface. Products feature less than or equal to 1.0 arc sec parallelism, 85% clear aperture, and 10-5 scratch-dig surface quality per MIL-PRF-13830. Applications include polarization control in lasers, fiber-optics, and telecommunications.
|
Polymer Optics offer surfaces as smooth as 60 angstroms.Syntec Technologies, Inc.
Pavilion, NY 14525
May 11, 2005 Manufactured using HRDT™ (high refraction diamond turning) technology, polymer optics are suited for applications requiring high refraction, heat resistance, and NIR performance. Products are available with complex structures in custom shapes, including spherical, aspherical, toroidal, cylindrical, cone, and plano. Lens surfaces can incorporate multiple diffractive elements as well as polyetherimide and polyethersulfone thermoplastic resins. |
 Building Management Control seamlessly unifies systems.Bosch Security Systems
Fairport, NY 14450 9199
May 10, 2005 Based on cross-platform, open connectivity standards, Building Integration System (BIS) provides unified point of control to manage one or multiple sites. Scalable building and enterprise management system seamlessly integrates physical and electronic security, access control, CCTV, fire systems, imaging, photo badging, and building management systems in open design with customizable HTML-based interface, which is accessible via Internet or intranet. |
 FTIR Module integrates with variety of sample interfaces.Midac Corp.
Irvine, CA 92614 6016
Feb 03, 2005 Illuminator M4500 is comprised of IR source and interferometer, which provide collimated output beam. It can be coupled with any sampling accessory equipped with its own IR detector to create dedicated analyzer. Internal IR source can be replaced with detector module for emissions work, or for use with external IR source. Data collection, post processing and report generation are provided by Grams/32-AI software or AutoQuant Pro™ package.
|
Optical Metrology System uses water immersion technique.Leica Microsystems AG
Switzerland
Sep 29, 2004 LWM500 WI optical mask metrology system incorporates immersion microscope objectives for optical critical dimension measurements on photomasks in semiconductor production. It supports critical dimension metrology requirements for R&D and production of 65 nm node reticles. Product combines water immersion with 248 nm DUV illumination to enhance optical resolution. Drop of water, applied between photomask substrate and objective, acts as immersion medium. |
 Metrology System offers 300 x 150 x 150 mm measuring range.View Engineering Inc.
Simi Valley, CA 93063 3348
Sep 15, 2004 Non-contact, benchtop Benchmark™ 300 features dual-magnification optical system that uses 2 cameras for near instantaneous magnification changes. Programmable Ring Light uses monochromatic red, green, blue, or white light for high-resolution imaging. Benchmark 300 offers measurement accuracy of U2 (XY plane) = (2.5 + 5L/1000) µm and resolution to 0.1 µm. It is suited for applications ranging from article inspection in QA lab to process control on production floor. |
 Eye Tracking System features lightweight optics.Applied Science Laboratories (ASL)
Bedford, MA 01730
Sep 09, 2004 Able to operate in bright, outdoor environments, Model 501-O Eye Tracker employs portable design with head-mounted optics that offers freedom of movement to user. Unit is also usable indoors. Scene is recorded with color camera mounted on headband or fixed tripod, while images from eye and scene cameras are displayed on 2 external 9 in. monitors or on computer monitor. EYEPOS operating software and EYENAL off-line data analysis software programs are included. |
 Optoelectronic HMIs make surfaces interactive.H2I Technologies
Nîmes 30900 France
Aug 30, 2004 Using optoelectronic technology, Human-Machine Interfaces meet requirements of harsh environments, offer resistance to wear, and require no maintenance as there are no moving mechanical parts. Units are suited for data entry systems in industrial and medical equipment as well as for household appliances, consumer electronics, multimedia kiosks, and ATMs used by general public. |
Magnification Optics feature built-in C-mount connectors.Infinity Photo-Optical Co.
Boulder, CO 80301
Jul 27, 2004 InfiniTube™ FM Series can be used with C-mount video cameras and infinity-corrected microscope objectives to provide high magnification images. Model FM-100 features 100 mm focal length for 1/3 in. and smaller sensors. Model FM-200 is for direct regulator-power use and is available in dual port version, Model FM-200/DP, and 90° bent version, Model FM-200/RA. All have internal focusing adjustment for touching-up focus from fixed position. |
 Light-to-Voltage Converters simplify board design.Texas Advanced Optoelectronic Solutions
Plano, TX 75074
Jun 15, 2004 TSL12, TSL13, and TSL14 integrate photodiode, transimpedance amplifier, and gain-setting resistors, while providing analog-output voltage proportional to light intensity. Devices operate in 3–5 V range, have spectral sensitivity range of 350–1050 nm, and require supply current of only 1.1 mA, typical. Operating temperature is -25 to +85°C. Rise time for TSL12, TSL13, and TSL14 is 20, 8, and 3 µsec, respectively. |
 Photonic Crystal Fibers suit laboratory research.Newport Corp.
Irvine, CA 92606
Feb 11, 2004 Photonic Crystal Fibers (PCF) contain air voids or holes, which serve 2 purposes; central hole forms hollow core fiber suitable for carrying high laser power levels, while arrays of tiny through holes lower effective refractive index of glass fiber core and/or cladding. Products include endlessly single mode fiber, hollow core fiber, polarization preserving fiber, photonic bandgap fiber, and fiber with non-linear performance. |
 Editing System is suited for digital intermediates.DVS Digital Video Inc.
Glendale, CA 91201
Feb 05, 2004 CLIPSTER multi-resolution editing system offers real-time primary color correction and open plug-in interface that enables flexible integration into different workflows. Equipped with film restoration tools, product features support for compositing with varied solutions. Unit also incorporates Centaurus PCI-X board, which handles uncompressed SD, HD, and 2K video streams and supports all popular formats, color spaces, frame rates, and resolutions to 2048 x 1556 pixels. |
Sampling Chamber characterizes optical substrates.Ocean Optics, Inc.
Dunedin, FL 34698
Aug 05, 2003 Variable-angle Reflection Sampling System couples to spectrometers and light sources to measure spectral reflectance of optical substrates from 200–1,100 nm at angles of incidence from 10° to 50°. Modular, optomechanical device has black anodized stainless-steel chamber with 2 ports for SMA 905-terminated optical fibers. Its 3-point fixed surface mount retains sample position, while thumbscrew locks optical assembly at fixed angle. |
 Safety Laser Scanner is offered with 7 meter range.SICK, Inc.
Bloomington, MN 55438
Jul 10, 2003 With 190° scanning range and 5.5 or 7.0 m Safety Zone radius options, S 3000 safeguards work areas, protecting personnel and equipment from damage and injury. Optoelectronic solution is suited for use in stationary and mobile applications for 2D or 3D horizontal and vertical safeguarding of point-of-operation, entry/exit, and area locations. Product offers 4 levels of integrated functionality for up to 16 user-definable protection scenarios. |
Optical System provides solid sampling in mass spectroscopy.Lambda Physik, Inc.
Fort Lauderdale, FL 33309
Jul 09, 2003 GeoLas™ PLUS integrates COMPex® 193 nm excimer laser, homogenized optical system, sample handling, sample visualization, and control software. It produces controlled, small particle sizes that result in low fractionation index near 1 for optimized data collection. Highly precise beam can be reproduced for sample after sample. Modular form allows unit to be moved between mass spectrophotometers and laboratories. |
 Laser Beam Shaper uses low-dispersion refractive optics.Newport Corp.
Irvine, CA 92606
Jun 25, 2003 Refractive Beam Shaper converts Gaussian laser beam input to produce collimated, flat-top beam that can propagate without change in power and intensity, or loss of uniformity over large distances. Optics produce no hard edges, speckles, or diffraction effects. Shaper functions over large bandwidth from far IR to deep UV allowing for use in many fields. Applications include illumination, laser processing, nonlinear optics, microscopy, and printing. |
 Ultraviolet LEDs are offered in various packaging styles.Bivar, Inc.
Irvine, CA 92618 2593
Mar 18, 2003 Housed in 3 and 5 mm packages, UV LEDs include TO-92, all metal and glass encapsulated UV LED and 1206 surface-mounted discrete UV LED package. Depending on device package, solid-state devices provide viewing angles from 30–140°. Operating temperature range is -20 to +85°C, typical radiant flux is 12 mW per chip, and typical stable wavelength varies from 390–410 nm. Devices demonstrate resistance to shock and vibration. |
 Optical Transceivers comply with InfiniBand standard.Stratos Lightwave Inc.
Chicago, IL 60706 4549
Jul 03, 2002 RJ Format transceivers operate at 2.5 Gb/sec in heavy traffic environments such as servers, remote storage devices, and multi-processor systems. Transceivers are available in single-port and quad-port packages with duplex LC connector interfaces at each port. Transceivers are available for 850 nm VCSEL multimode optical fiber applications with link distances up to 250 m, and 1310 nm Fabry-Perot Laser single mode optical fiber applications for link distances up to 10 km.
|
(Showing headlines 21 - 40) 1 2 3
|
|
|