|
|
|
|
Optics & Photonics ->
Light Sources
Light Sources
(Showing headlines 41 - 60) 1 2 3 4 5 6
|
EUV Light Source targets HVM testing applications.Energetiq Technology
Woburn, MA 01801
Mar 06, 2009
Operating at pulse rate of 10 kHz, EQ-10HR produces EUV light suited for infrastructure development for EUV lithography. It incorporates electrodeless Z-Pinch technology, which inductively couples current into discharge plasma, optimizing plasma control and stability and confining plasma away from source components. Product offers simplified integration into process tools and maintains repetition rate over billions of pulses.
|
 Handheld Optical Light Source weighs only 300 g.GAO Tek Inc.
Toronto M1B2K4 Canada
Feb 26, 2009
Suitable for installation, construction, and maintenance of fiber optics, GAO08231 features integrated frequency selection function, and offers modulation frequencies of CW, 2 Hz, 270 Hz, 1 kHz, and 2 kHz. Features include 1,310/1,550 or 850/1,300 wavelength, output power of -7 to -6 dBm, operating temperature of -10 to 60°C, and storage temperature of -25 to 70°C. Powered by rechargeable battery, device offers output stability of ±0.05 dB/15 min or ±0.1 dB/8 hr.
|
Optical Light Source delivers 10 nm of spectral width.GAO RFID Inc.
Toronto Canada
Feb 25, 2009
Capable of working continuously for 40 hr with three 1.5 V alkaline batteries, GAO08221 Light Source can be used for telecom and CATV testing and maintenance of fiber optics. It features wavelengths of 1,310 or 1,550 nm, -7 to -6 dBm output power, and output stability of 0.05 dB/15 min or 0.1 dB/8 hr. Product has operating temperature of -10 to 60°C, storage temperature of -25 to 70°C, and FC/PC optical connectors.
|
 Optical Light Source provides 2-4 wavelength outputs.GAO Tek Inc.
Toronto M1B2K4 Canada
Feb 24, 2009
Measuring 152 x 74 x 26 mm and weighing 180 g, GAO LP-226 features LCD and 3 AA 1.5 V battery power supply. Output stability is ±0.05 dB for 15 min and ±0.1 dB for 8 hr and unit offers modulation frequencies of CW, 270 Hz, and 1 and 2 KHz. It features operating temperature of -10 to +60°C and storage temperature range of -25 to +70°C. Emitter type is FP-LD and it incorporates FP/PC optical connector, with FC/SC/ST connector optional.
|
 Portable Laser Light Source is used for fiber optic testing.GAO Tek Inc.
Toronto M1B2K4 Canada
Feb 24, 2009
Used in field or lab to measure long-distance and local optical networks, GAOXG3020 fiber optic instrument has single-output connector that provides stable laser power at dual 1,310 and 1,550 nm wavelengths. Unit operates in continuous wave mode or 2 kHz modulated mode for up to 12 hr and supports operating wavelengths from 750-1,700 nm. Along with low-battery indication, features include adjustable output and user-selectable disable function.
|
High Stability Light Sources deliver 1 to 3 wavelengths.GAO Tek Inc.
Toronto M1B2K4 Canada
Jan 27, 2009
Based on intelligent microprocessing system, GAO 3100 Series relies on automatic power and temperature control techniques. Units feature RS-485 and RS-232 communication ports, digital LCD display, and adjustable, custom optical output power. Devices are suitable test instruments for simulating various conditions and are used in manufacturing, testing, and maintenance of passive optical components.
|
 LED Ring Light suits inspection, assembly, and rework.Luxo Corporation
Elmsford, NY 10523
Jan 16, 2009
Intended for use with binocular and trinocular microscopes, Dimmable LED-High Output Ring Light features 80 LEDs that draw 18 W of energy while producing up to 5,800 ft candles at 4.5 in. working distance. LEDs are distributed among 2 concentric rings of lights and are controlled via 8 quadrant switches. Color temperature of 6,000°K, combined with dimming to 15% output, makes ring light suited for inspection of circuit boards, surface cracks and defects, welds, and solder joints.
|
 Digital Light Source characterizes image sensor performance.Gamma Scientific
San Diego, CA 92123 1876
Dec 09, 2008
Integrated into new or existing test systems, RS-5-93K facilitates focal plane array testing while offering Hi-Res digital brightness control with optimal linearity and uniformity. Light level setting to 1 part in 65,525 is provided in absolute, NIST-traceable, radiometric and/or photometric units. Spectral distribution ranges from UV into NIR, RGB, and broadband white, featuring linearity deviation under 0.25% rms FS over entire brightness adjustment range.
|
Photonic Tools suit lab and manufacturing environments.JDSU
San Jose, CA 95131
Oct 07, 2008
Operating independently or in tandem, c-Series Compact Photonic Tools address key applications from general-purpose, lab-based optical measurements to insertion loss and return loss measurements for FTTx passive components and fiber optic connectors. Single-function bench-top testers include cOPM-A1 Optical Power Meter, cFPL-A1 Fabry-Perot Light Source, and cORL-A1 Optical Return Loss Meter. Each has USB interface and offers feedback required for robotic/automated assembly equipment.
|
Light Source is suited for entertainment venues.LUXIM Corp.
Sunnyvale, CA 94089
Sep 15, 2008
Enabling energy-efficient lighting equipment for large entertainment venues, LIFI(TM)-ENT-30-02 solid-state, high-intensity light source outputs up to 17,000 lumens from small emitter in forward intensity pattern with CRI of 94. It has 10,000 hr lifetime and reduces power consumed by moving heads, follow spots, as well as other stage and studio lighting equipment. Further power conservation is possible via dimming support, and heat dissipation levels provide quiet operation.
|
 Digital Light Source suits compliance testing applications.Gamma Scientific
San Diego, CA 92123 1876
Sep 12, 2008
Designed for cockpit display backlights where lighting changes from tungsten and fluorescent to solid-state LEDs, RS-5NVIS Digital Light Source tests and calibrates ANVIS radiometers and spectroradiometers. It features light level setting to 1 part in 65,535 in absolute, NIST-traceable, ANVIS radiance and luminance units, as well as linearity deviation of less than 0.25% rms. Unit is equipped with manual control and ASCII computer interface control via built-in RS-232 port.
|
Surgical Lamp offers high-intensity light in compact package.Lumitex, Inc.
Strongsville, OH 44136
Aug 20, 2008
Available in 5.8 x 3.5 x 2.8 in. portable package weighing 2.2 lb, LumitexMD(TM) BRICK medical grade light source uses 24 W Solarc® high-intensity arc lamp to provide white light for surgical site visualization. Unit comes with ACMI connector, common international power plugs, and mounting clamp for attachment to IV pole or surgical table accessory side rail. Light source can be used in combination with LightMat®, VersaLight®, or headlight in surgical centers.
|
Top View LEDs have luminous efficacy of 68 and 70 lm/W.Seoul Semiconductor
Geumcheon-Gu 153-801 Korea (south)
Aug 07, 2008
With life expectancy that exceeds 50,000 hrs, Models CAWT722-S and CWT722-S LEDs have high color rendering index (CRI) and are suited for indoor lighting. Warm white Model CAWT722-S has CRI of 96 and achieves 68 lm/W, while pure white Model CWT722-S has CRI of 92 and produces 70 lm/W. Both models measure 6.0 x 5.0 x 2.5 and have viewing angle of 120°.
|
 Light Source System suits product and performance testing.McPherson, Inc.
Chelmsford, MA 01824
Aug 01, 2008
With ability to test varied long- and short-wavelength UV regions, Ultraviolet Photon Excitation system provides in-laboratory access to vacuum-ultraviolet for material analysis, spectral calibration, and photo-excitation spectroscopy. It combines properties of computer optimized, all-reflective, spectrally tunable monochromator with MgF2 window Deuterium and/or windowless hollow cathode light source. Light source emission wavelengths include 30.4, 58.4, 73.7, 102, and 121.6 nm.
|
Laser Light Source ranges from 170 nm to beyond visible.Energetiq Technology
Woburn, MA 01801
Jun 27, 2008
Incorporating light collection optics and power supply, EQ-1000 LDLS(TM) Laser-Driven Light Source uses sealed Xenon gas bulb and can be configured for broad spectrum output in UV-VIS spectroscopy, biological imaging, circular dichroism spectroscopy, and general scientific research.
|
 Microscopy Light Source has computer-controlled intensity.TOFRA, Inc.
Palo Alto, CA 94303
Jun 06, 2008
RGB LED Light Source enables independent control of red (619 nm), green (515 nm), and blue (465 nm) LEDs to create any desired color, including white light, for visual observation. Color images can be produced from monochrome cameras, giving full non-interpolated color at every pixel. Light source head mounts instead of condenser on upright microscopes and does not create any vibration or noise. Light source controller connects to computer serial or USB port.
|
High-Intensity Light Source suits street and area lighting.LUXIM Corp.
Sunnyvale, CA 94089
May 19, 2008
Solid-state light source, LIFI(TM) STA-40-01, has compact, directional beam with CRI of 95 that promotes light distribution. Source is rapid on, rapid restrike, dimmable, and remotely addressable. These features enable energy-saving modes such as daylight harvesting, occupancy sensing, and demand response dimming. Retrofitting into existing fixtures, source delivers 22,000 lumens with 120 lumens/W source efficiency and 30,000 hr life.
|
Light Ring is available in 850 or 880 nm center wavelengths.Optek Technology, Inc.
Carrollton, TX 75006-6905
May 13, 2008
RoHS-compliant OPA80 and OPA83 Series near-infrared light sources are available with ring sizes from 0.625 in. ID/1.25 in. OD to 1.25 in. ID/2.25 in. OD. Typical forward voltage is 1.35 VF, reverse voltage per emitter is 2.0 V, with continuous forward current of 50 mA and peak pulsed forward current of 1.0 A at 1% duty cycle. Series OPA80 12 V light ring comes with ambient light sensor to minimize current consumption, while Series OPA83 5 V light ring comes without sensor.
|
LED Light Sources suit all borescopes and fiberscopes.Medit, Inc.
Winnipeg, MB R3C2B3 Canada
Mar 24, 2008
Offering alternative to halogen and metal halide light sources, portable Superbright LED Light Sources offer low-power 3 W LED element with super-magnifying lens, allowing average of 28,000-46,000 Lux and over 1,000,000 hours of lamp life per source. Available with either ACMI or STORZ threading, units are suitable for variety of medical, veterinary, and industrial endoscopes, fiberscopes, and borescopes.
|
LED Light Source suits high-temperature medical equipment.Data Display Products
El Segundo, CA 90245 4630
Mar 24, 2008
LED Lighting Assembly is low-profile LED light source that provides task lighting in surgical fluid and blanket warmer, keeping materials at consistent temperature. Able to withstand maximum ambient temperature of 200°F, LED assembly reduces fluid warmer's power consumption and enables thermal control by eliminating temperature spikes. System utilizes surface mount technology and can be designed for a wide range of applications.
|
(Showing headlines 41 - 60) 1 2 3 4 5 6
|
|
|