Optics & Photonics
(Showing headlines 741 - 760) << 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 ...
|
Fiber Receiver carries HDMI signals up to 1,000 ft.Crestron Electronics, Inc.
Rockleigh, NJ 07647
Mar 10, 2011
Accepting all analog and uncompressed HD A/V signals, control, data, and Ethernet from single multimode fiber strand, DM-RMC-150-S DigitalMedia 8G(TM) Fiber Receiver and Room Controller outputs standard HDMI to display device. Unit includes RS232, IR, and Ethernet ports as well as relays, closure sensing, and USB ports for additional control options. Additionally, Model DM-RMC-150-S provides separate analog stereo audio output and can function as keyboard/mouse extender.
|
C-Band Tunable Laser meets 100 Gbps transmission demands.OFS, Specialty Photonics Division
Avon, CT 06001
Mar 10, 2011
Full-band tunable laser delivers optical output of higher than 40 mW with linewidth of lower than 500 kHz. With tunable wavelength range of 1,528-1,564 nm (C band), laser offers performance suited for use as signal light source and/or local light source for digital coherent communication systems. Side-mode suppression ratio is greater than 40 dB, average relative intensity noise is less than -145 dB/Hz, and wavelength stability is less than ±2.5 GHz.
|
 QSFP+ Optical Transceivers combine high-density and low power.TE Connectivity Ltd.
Berwyn, PA 19312
Mar 09, 2011
Compact, 40 Gbps QSFP+ optical transceivers feature 4 independent optical transmit and receive channels. Offering power dissipation of 0.8 W and electrically hot-pluggable design, parallel fiber optical modules include digital diagnostic monitoring interface that lets users manage and monitor key module parameters. Products also include latch mechanism for insertion into board-mounted cages and MPO/MTP-terminated fiber ribbon for optical connectivity.
|
Two-Camera Imaging Adapter suits microscopy applications.Andor Technology Ltd.
South Windsor, CT 06074
Mar 09, 2011
Compatible with Andor's low-light imaging cameras, TuCam enables simultaneous 2-camera imaging, making it suitable for concurrent detection of 2 different fluorophores in experiments such as co-localization FRET or ratiometric ion signaling. Unit is available in C- or CSUX-mount versions with 22 mm aperture, achromatic lenses for 425-700 nm image, greater than 96% transmission, and less than 0.5% distortion. By-pass mode and first surface mirror provide flexibility.
|
 Wireless Access Point Wall Bracket enables horizontal mounting.Oberon, Inc
State College, PA 16801
Mar 08, 2011
Accommodating hard lid and other environments where ceiling mounts are not possible, Model 1029-00 Wall Mount Bracket ensures wireless access points (APs) are securely placed in recommended horizontal configuration so they can achieve optimal coverage. Product is constructed of white powder-coated steel and works with access points from most manufacturers. Conduit, raceways, and cable can be securely terminated inside bracket, promoting clean appearance.
|
 Shortwave IR Line-Scan Camera has square pixel design.SUI
Princeton, NJ 08540
Mar 08, 2011
Model SU1024LDM SWIR line-scan camera features 1,024-pixel imaging and has square pixel design that ensures pixel height is defined by metal mask, optimizing measurement accuracy of objects being imaged. Device has 14-bit base Camera Link® interface, flexible triggering, and line rates up to 46,000/sec for its entire pixel width. Measuring 76 x 74 x 61 mm, compact InGaAs camera has mounting points on 4 of its 6 sides and rugged housing that supports operating temperature of -10 to +50°C.
|
 Laser Gas Delivery System maximizes resonator efficiency.CONCOA
Virginia Beach, VA 23454
Mar 08, 2011
Incorporating M2 beam-mode quality technology, 619 Series minimizes atmospheric contamination during resonator gas cylinder exchange. Stable emission is achieved through low internal volume design and smooth flow paths that eliminate entrapment of moisture or hydrocarbons. Operating from -40 to 140°F, system offers PTFE seat for 3,000 psig inlet or Kel-F® seat for 4,500 psig inlet. All-metal seal design incorporates stainless steel diaphragms and has 1 x 10-9 He cc/sec leak rate.
|
Microwave Handheld Spectrum Analyzers facilitate field testing.Agilent Technologies, Inc.
Santa Clara, CA 95051
Mar 08, 2011
Respectively capable of measurements from 1 MHz to 20 GHz and 13.6 GHz, N9344C and N9343C are tunable to 9 kHz and designed for those who install, maintain, and troubleshoot RF/microwave systems, monitor spectrum, or manage interference in field. Fanless design incorporates GPS receiver/antenna and tracking generator. RF performance is -155 dBm/Hz DANL, with min sweep time less than 2 msec, and dedicated applications facilitate/accelerate spectrum monitoring and interference analysis.
|
Digital Super Zoom Camera offers multi-recording functionality.Olympus Imaging America Inc.
Center Valley, PA 18034
Mar 08, 2011
Featuring 24x optical wide-zoom lens and 3.0 in. LCD, Model SZ-30MR can simultaneously capture 1,080p HD video and 16 megapixel still images. Unit includes full resolution burst mode, which enables continuous shooting, in rapid succession at up to 9 frames/sec. With 3D Photo Mode, camera captures 2 shots of scene from 2 different angles to create still photos that can be viewed in 3D. Eye-Fi(TM) card compatibility enables automatic wireless uploading of images to website or PC.
|
 Solid Aluminum Breadboards offer vertical bracket accessories.Newport Corporation
Irvine, CA 92606
Mar 07, 2011
Offering stable platform for optical components and sub-assemblies, SA2 Series comes in 6 x 24 in., 6 x 36 in., 12 x 36 in., and 24 x 36 in. sizes to afford flexibility for optical experiments. Grid of tapped holes, which extends to within 0.5 in. of plate edges, optimizes mounting surface, while in-grid counter-bored holes and deep edge chamfers facilitate lifting, alignment, and integration onto optical tables. All versions are deep black anodized, minimizing surface reflection.
|
Hybrid Video Recorders support analog and digital video.Pelco Inc
Clovis, CA 93612-5699
Mar 03, 2011
Model DX4800, capable of recording full frame rate video at full 4CIF resolution for all cameras, and DX4700 both record up to 30 images/sec on all channels. Available with 8 or 16 analog channels, units also support 2-megapixel cameras and offer user interface that enables custom installation. They are suited for processing images to watch registers, cash counting operations, merchandise, or lobbies and entrances for companies still utilizing analog video surveillance infrastructure.
|
 O-Band Tunable Laser combines high power and low noise.Yenista Optics S.A.
LANNION France
Mar 02, 2011
Using optical cavity design, Tunics T100 operates from 1,270-1,340 nm with up to +6 dBm output power and signal to spontaneous emission ratio (SSER) of over 80 dB/0.1 nm. Self-filtered external cavity laser technology accommodates needs of engineers developing and testing components for 40 and 100 GbE and FTTH/PON networks. Suitable uses include characterizing narrow bandwidth filters as well as testing high-speed transmission systems as light source.
|
Thermal Imaging Camera utilizes Class II laser.Ideal Industries, Inc.
Sycamore, IL 60178
Mar 02, 2011
Designed for non-contact preventive maintenance, HeatSeeker® 160 delivers 160 x 120, 19,200 pixel thermal image and 2 megapixel visual image in wide temperature range of 14-482°F with ±2°C accuracy. Four cursors, moveable anywhere on live 3.5 in. LCD screen, can be selected to identify hottest and coldest temperatures in real time. Fully radiometric, IP54-rated unit identifies potential problems before they occur by detecting hot spots on motors, switch gear, processing pipes, and fuse panels.
|
 Microspectrophotometer covers UV-visible-NIR range.CRAIC Technologies Inc.
San Dimas, CA 91773
Mar 01, 2011
Integrating spectrophotometer, high resolution digital imaging, UV-visible-NIR microscope, and software, FLEX(TM) is designed for spectroscopic analysis of microscopic samples. Multifunctional tool can acquire images and spectra from deep UV to NIR and analyze samples by absorbance, reflectance, luminescence, or fluorescence. Along with DirecVu(TM) optics, additional packages are available for measuring everything from refractive index of microscopic samples to thin film thickness.
|
Mode Converter Fiber Coupler uses Gaussian profile fiber input.JK Lasers
Warwickshire CV21 1QN United Kingdom
Feb 25, 2011
Mode Converter Fiber Coupler (MCFC) takes Gaussian profile single-mode fiber input from fiber laser and couples it into Luminator(TM) fiber. Focused spot sizes in range of 60-1,500 µm can be selected by use of appropriate Luminator process tools. Product has detachable output fiber and suits welding applications where profile and small spot size of Gaussian beam are not optimal, such as butt welding parts with fit-up tolerances larger than Gaussian spot size or thin foil welding.
|
 Low-Loss RF Combiner speeds PXI measurement speed.Aeroflex
Irvine, CA 92618
Feb 24, 2011
Used in conjunction with signal generator and RF digitizer modules, 3065A RF combiner operates from 250 MHz to 6 GHz and addresses needs of RF test system engineers working in cellular handset or RFIC and component manufacturing. Dual-input module, in addition to providing summed signal outputs, supports various combinations of input and output switched path configurations to enable testing of single- and multi-port RF devices without need to alter connections.
|
 LED Magnifiers feature 4 diopter lenses.White, O.C., Co.
Thorndike, MA 01079
Feb 24, 2011
Running on 15 V, Green-Lite LED Magnifiers provide broad field lighting using 12-LED array that is wrapped in die cast ESD-safe housing. Surface mount LEDs deliver 6,500 K bright white light at virtually any focal length. Smart Control module allows operator to change LED zones of lighting to contrast and shadow work. For energy management, timer can be enabled to shut off each magnifier every 4 hours and 5 minutes.
|
 Fixed Gas Detection Transmitter can evolve with facility needs.Scott Safety
Monroe, NC 28111
Feb 23, 2011
Supporting detection of toxic and combustible gases, Freedom 6000 incorporates universal transmitter into fixed gas detection system to facilitate maintenance and minimizing training. Sensor technology with modular design aids component replacements and field upgrades, and accessories are available to support unique application requirements. Gas trending data information is available locally via LCD screen, and additional options include modbus and relay outputs.
|
HD Microimaging System supports research visualization.Optronics
Goleta, CA 93117
Feb 23, 2011
Designed for research and experimental microsurgery and micro-dissection, VITOM HD couples KARL STORZ optical instrument with full HD camera system. Optical design supports working distance of 25-60 cm and 6 cm depth of field. System uses extracorporeal magnification and full 1920 x 1080 imaging technology to create immersive visualization, documentation, and teaching experience. Crafted using stainless steel components, VITOM HD is corrosion-resistant and autoclavable for sterile applications.
|
 Optical Data Couplers serve material handling applications.Pepperl + Fuchs, Inc.
Twinsburg, OH 44087 2245
Feb 22, 2011
Helpful for maintenance and diagnostics in remote locations, LS680 Series can transmit signals, such as live video and other communication information, without operating controls or programming. Tamper-proof, plug-and-play solutions transmit protocol-free, accommodating various industrial Ethernet topologies without requiring any changes. Series transmits signals from 0-150 m with 180 m threshold distance and data at rate of 100 Mbps via 100 Base-TX interface.
|
(Showing headlines 741 - 760) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202
|
|
|