Latest New Product News
(Showing headlines 73191 - 73210) << 3660 3661 3662 3663 3664 3665 3666 3667 3668 3669 3670 3671 3672 3673 3674 3675 3676 3677 3678 3679 ...
|
Amplifiers integrate gain-setting resistors on-chip.Linear Technology Corp.
Milpitas, CA 95035
Nov 21, 2006
With -3 dB bandwidth of 300 MHz, LT6402 differential amplifier provides on-chip filter and output common mode voltage pin, and is available in 6, 12, and 20 dB fixed gain options. Model LT6411 dual-selectable gain amplifier has -3 dB bandwidth of 650 MHz and slew rate of 3,300 V/µs, with independently selectable gains, consuming 16 mA supply current. Device can be disabled when inactive, dropping consumption to less than 0.35 mA max per amplifier.
|
 DDC Pumps offer 3 displacements in one housing size.Sauer-Danfoss
Ames, IA 50010
Nov 21, 2006
Providing displacements of 25, 30, and 35 cc, Direct Displacement Control Pumps feature internal Neutral Return Mechanism, which is protected and always lubricated. Units are designed for closed-loop machine operations and are suited for wide area mowers, sweepers, mini excavators, walk-behind skid steer loaders, small tractors, and other machines used in areas where high noise levels are an issue.
|
 Power Modules carry 6-8 A of current at 20°C.ERNI Electronics, Inc.
Midlothian, VA 23112
Nov 21, 2006
MicroSpeed(TM) Power Module connectors, with 2.0 mm contact pitch, are suited for use with devices such as CPUs, drives, and LCD panels. While male versions come in 1, 2, 9, and 10 mm heights, female versions are offered in 4, 6, 8, and 10 mm heights. Series enables stacking heights from 5-20 mm, addressing every PCB arrangement requirement. It offers multiple-connector mating capability and features integrated 3-point double beam female contact.
|
 Clamp prevents disconnection of computer cables.Glacier Computer
Amherst, NH 03031
Nov 21, 2006
Designed for GX Series of industrial computers, Glacier Clamp provides solid grip on PS/2 and/or USB connection and is suited for harsh environments where extremes of temperature, shock, and vibration are experienced. Clamp prevents connection from accidentally being pulled out or loosening from vibration over time.
|
 H2S Gas Sensor Module has 180 day calibration interval.Sierra Monitor Corp.
Milpitas, CA 95035 6825
Nov 21, 2006
FM-approved for performance and area safety requirements, 4501-05 hydrogen sulfide (H2S) gas sensor module features 4-20 mA, 2-wire, loop-powered design. It is supplied with stainless steel transmitter and sensor enclosure. Design combines non-intrusive calibration with integral scrolling menu-driven LCD for access to gas status, calibration information, and diagnostics. Product offers variable range selection and mounting configurations.
|
 Bowed Handle installs without screws or tools.DIRAK
Chantilly, VA 20151-1220
Nov 21, 2006
Incorporating D-SNAP technology, SNAP-LINE Bowed Handle functions as both handle and latch, eliminating need to use separate products. Spring-loaded wings are inserted into channel in handle housing. As wings retract after passing through cutout, SNAP-LINE handle is held securely in place, even in severe vibration applications. Constructed of zinc die-cast, handle can be used for right- or left-hand applications and for horizontal or vertical doors.
|
 Electronic Ballasts suit compact fluorescent applications.American Ballast
Fremont, CA 94538
Nov 21, 2006
Featuring universal input voltage of 108-305 V, Electronic Ballasts are compatible with most infrared-based remote control applications as well as multiple lamp wattages and multiple number of lamps, including D, Twin Tube, Quad Tube, Triple Tube, and Circline lamps. Units are available with bottom or side entry terminal blocks and include color-coded connectors. Auto restart function and internal fuse maintain ballasts' circuit integrity.
|
 Pump Controller offers sensorless flow measurement.ITT Goulds Pumps
Seneca Falls, NY 13148
Nov 21, 2006
Designed for PumpSmart PS200, PumpSmart v5.0 can calculate flow of centrifugal pumps within ±5% of pump's rated flow without need for external instrumentation. Function mathematically models pump power curve with only 4 points of CDS pump performance curve data. Advanced Pump Protection takes into account hydraulic and mechanical losses associated when changing speed of centrifugal pump, while Positive Displacement Pump Protection protects pumps with constant torque load.
|
 Pressure Washers are operated by wireless remote control.Landa Water Cleaning Systems
Camas, WA 98607
Nov 21, 2006
VHG hot water pressure washers include LanCom remote control device that can be used to turn them on or off, ignite burner to create hot water, or switch from clear rinse to soapy wash water from up to 300 ft line of sight. Electrically powered, 24 x 53 in. units have flow rate of 2.5-8 gpm and spray pressure of 1,000-3,000 psi, and are heated by natural gas or liquid propane. Heat is retained in leak-free, cold-rolled, ½ in. Schedule 80 steel pipe coils.
|
 Digital Servo Drive features asynchronous control.AC Technology Corp.
Uxbridge, MA 01569 2001
Nov 21, 2006
Compatible with G-motion line of asynchronous gear motors, Model 940 PositionServo Drive with motion controller uses BASIC-like motion-programming language to provide indexing and positioning but can also run in traditional velocity or torque modes. Electronic Programmable Module removable memory chip allows servo control parameters and motion control programs to be transferred from one drive to another, even without power applied.
|
 Dial Loader automates cut-off of shaped tubing.Hautau Specialty Machines
College Corner, OH 45003
Nov 21, 2006
Used to automate loading of tube shears or saw cut off machinery, dial loader is designed for continuous processing of various shaped tubing. Loader handles complete bundles of mill length tubing, which is supported by 4 heavy-duty steel arms with nylon rotary dials positioned at ends. Split design dials accommodate up to 24 different sizes/shapes while orienting tubing for optimal cutoff angle, such as 45° for square and 30° for rectangular tubing.
|
 Portable Calibrator delivers precise concentrations of gas.VICI Metronics, Inc.
Santa Clara, CA 95051
Nov 21, 2006
Offered with choice of plumbing and flow configurations, Dynacalibrator® Model 150 generates precise ppm or ppb concentrations of chemical compounds in gas stream using permeation devices as trace gas source. Passivated glass-coated permeation chamber houses permeation device, with measured inert carrier gas sweeping calibration gas/vapor from chamber. Digital controller maintains chamber temperature at set point with accuracy of ±0.01°C, traceable to NIST standards.
|
 System-On-Chip offers industrial motor circuit protection.Teridian Semiconductor
Irvine, CA 92618-5201
Nov 21, 2006
Featuring Single Converter Technology(TM), Model 71M6403 Electronic Trip Unit can be tuned according to voltage, current, rate of voltage increase, and rate of current increase. It trips instantaneously on threshold events within 7 ms from power on, or can be set to trip on delay. Unit incorporates 22-bit delta-sigma ADC, 7 current sensor inputs, digital temperature compensation, precision voltage reference, 32-bit programmable computation engine, timers, RTC, 2 UARTs, and 8-bit MCU.
|
 Pressure Switch controls automatic water systems.Dwyer Instruments, Inc.
Michigan City, IN 46361
Nov 21, 2006
Featuring adjustable setpoint and deadband, Mercoid Series CXA is available with normally open or normally closed SPST snap switch and can range from 15-180 psig. With 20 A electrical rating, unit is suitable for water well pumps and other pumping systems. Switch is not mounting sensitive, which helps ease installation.
|
 Flow Indicators suit analog signal applications.Dwyer Instruments, Inc.
Michigan City, IN 46361
Nov 21, 2006
Accepting all standard process signals such as 4-20 mA, 1-5 V, and 0-5 V, Series FIV flow rate/totalizer/batch controllers feature 7-segement LED display that provides 4½ digits of flow rate and 6 digits of total. For applications requiring more than display of rate or total, meters can be equipped with 2 relays and 4-20 mA retransmission output. Relays can also be used for alarming based on flow rate or for batch controlling based on flow total.
|
 DC/DC Converters meet Intel processor specifications.C & D Technologies
Mansfield, MA 02048-1151
Nov 21, 2006
Comprising 6 models, VRM11.X Series offers choice of 1U or 2U form factors and both 80 and 150 A current options. All models are RoHS-compliant and include DAC programmable output voltage, power good output, differential remote sense, and remote enable. Supervisory functions such as output over-current, short circuit protection, over-temperature indicator, and output current level signal are also provided. Three versions with no load line are suitable for non-Intel applications.
|
 Strut Fastener speeds installation of trapeze supports.Thomas & Betts Corp.
Memphis, TN 38125
Nov 21, 2006
Featuring steel construction, Kindorf® Trapnut(TM) cuts installation time of trapeze framing and support systems by eliminating need to thread nut from either end of threaded rod. Scissor design, consisting of top and bottom plates fastened with pin, enables plates to swivel open and close. Closing at any position on threaded rod, scissor design and precision threads allow for fine-tuned adjustment in either direction.
|
 Plasma Cutting System includes pre-installed condenser.Thermal Dynamics Corp.
Chesterfield, MO 63017
Nov 21, 2006
Featuring portable design, Drag-Gun® Plus offers maximum arc visibility for operator control and includes SureLok® torch, which provides ½ in. genuine cut capacity. Built-in air compressor minimizes moisture content in air supply. Cutting system delivers full cut capacity at 230 V @ 15-35 A, which is continuously adjustable.
|
Industrial Grade Chassis feature front-accessible I/O.Advantech Automation Corp.
Cincinnati, OH 45240
Nov 21, 2006
Bracketed for wallmount or desktop applications, Model IPC-5120 supports Micro-ATX motherboard with up to 4 half-length PCI slots, while Model IPC-7120 supports standard ATX motherboard and up to 7 half-length PCI slots. Both RoHS-compliant units are 12.1 in. deep and provide in-chassis rear-in/front-out airflow with one 85 cfm fan and one 10 cfm fan. Front access I/O includes keyboard and mouse PS/2, LAN, USB, and video ports, as well as power cord connector.
|
At-Speed DFT Solution optimizes nanometer design efficiency.LogicVision, Inc.
San Jose, CA 95110
Nov 21, 2006
ScanBurst(TM) combines Mentor's automatic test pattern generation (ATPG) and embedded compression products, FastScan(TM) and TestKompress®, to promote accuracy and effectiveness in detecting subtle delay defects prevalent in nanometer SoC designs. This integrated DFT (Design-for-Test) solution complements existing ATPG-based DFT techniques by providing environment to insert scan and clock control structures for at-speed testing based on BurstMode Timing(TM) technology.
|
(Showing headlines 73191 - 73210) << 3660 3661 3662 3663 3664 3665 3666 3667 3668 3669 3670 3671 3672 3673 3674 3675 3676 3677 3678 3679 3680 3681 3682 3683 3684 3685 3686 3687 3688 3689 3690 3691 3692 3693 3694 3695 3696 3697 3698 3699 3700 3701 3702 3703 3704 3705 3706 3707 3708 3709 3710 3711 3712 3713 3714 3715 3716 3717 3718 3719 3720 3721 3722 3723 3724 3725 3726 3727 3728 3729 3730 3731 3732 3733 3734 3735 3736 3737 3738 3739 3740 3741 3742 3743 3744 3745 3746 3747 3748 3749 3750 3751 3752 3753 3754 3755 3756 3757 3758 3759 3760 3761 3762 3763 3764 3765 3766 3767 3768 3769 3770 3771 3772 3773 3774 3775 3776 3777 3778 3779 3780 3781 3782 3783 3784 3785 3786 3787 3788 3789 3790 3791 3792 3793 3794 3795 3796 3797 3798 3799 3800 3801 3802 3803 3804 3805 3806 3807 3808 3809 3810 3811 3812 3813 3814 3815 3816 3817 3818 3819 3820 3821 3822 3823 3824 3825 3826 3827 3828 3829 3830 3831 3832 3833 3834 3835 3836 3837 3838 3839 3840 3841 3842 3843 3844 3845 3846 3847 3848 3849 3850 3851 3852 3853 3854 3855 3856 3857 3858 3859 3860 3861 3862 3863 3864 3865 3866 3867 3868 3869 3870 3871 3872 3873 3874 3875 3876 3877 3878 3879 3880 3881 3882 3883 3884 3885 3886 3887 3888 3889 3890 3891 3892 3893 3894 3895 3896 3897 3898 3899 3900 3901 3902 3903 3904 3905 3906 3907 3908 3909 3910 3911 3912 3913 3914 3915 3916 3917 3918 3919 3920 3921 3922 3923 3924 3925 3926 3927 3928 3929 3930 3931 3932 3933 3934 3935 3936 3937 3938 3939 3940 3941 3942 3943 3944 3945 3946 3947 3948 3949 3950 3951 3952 3953 3954 3955 3956 3957 3958 3959 3960 3961 3962 3963 3964 3965 3966 3967 3968 3969 3970 3971 3972 3973 3974 3975 3976 3977 3978 3979 3980 3981 3982 3983 3984 3985 3986 3987 3988 3989 3990 3991 3992 3993 3994 3995 3996 3997 3998 3999 4000 4001 4002 4003 4004 4005 4006 4007 4008 4009 4010 4011 4012 4013 4014 4015 4016 4017 4018 4019 4020 4021 4022 4023 4024 4025 4026 4027 4028 4029 4030 4031 4032 4033 4034 4035 4036 4037 4038 4039 4040 4041 4042 4043 4044 4045 4046 4047 4048 4049 4050 4051 4052 4053 4054 4055 4056 4057 4058 4059 ...
|
|
|