|
|
|
|
|
Latest New Product News
(Showing headlines 25131 - 25150) << 1257 1258 1259 1260 1261 1262 1263 1264 1265 1266 1267 1268 1269 1270 1271 1272 1273 1274 1275 1276 ...
|
 Environmental Monitors serve Web pages for remote data access.Newport Electronics, Inc.
Santa Ana, CA 92704
Aug 02, 2010
Used for remote surveillance of environmental conditions, Virtual Chart Recorders(TM) let users view virtual charts as well as record temperature, relative humidity, dew point, and barometric pressure over Ethernet network or Internet via Web browser. Instruments can trigger alarm - email or cell phone/PDA text message - if reading goes above/below user-determined set point, and removable 2 GB SD Flash Memory card stores up to 7 years of readings taken at 10 sec intervals.
|
 PTFE Dialyzers feature reusable design.Harvard Apparatus, Inc.
Holliston, MA 01746 1371
Aug 02, 2010
Suited for equilibrium dialysis, regular dialysis, or electro-elution in ElectroPrep(TM) tank, PTFE DIALYZERS(TM) cover volumes of 25, 50, 100, 250, 500, 1,000, and 1,500 µl. Units consist of double-sided chambers that can be sealed with another chamber plus 2 solid caps, or with 2 open caps for use with separate membranes between them. Open main chambers facilitate sample introduction and withdrawal. To accelerate dialysis, DIALYZERS(TM) can be placed in temperature-controlled device.
|
 Position/Displacement Sensors operate in hostile environments.Kaman Aerospace, Measuring & Memory Systems
Middletown, CT 06457
Aug 02, 2010
Using dual-coil design to minimize thermal and radiation effects, inductive-based Non-Contact Position/Displacement Sensors operate from -320 to +1,000°F continuous and up to +1,200°F short term. Units feature sealed, all-Inconel construction and use metal-jacketed, mineral-insulated cable. Available in single- and multiple-channel models with NEMA enclosure, sensors are suitable for highly corrosive gas or liquid environments as well as radiation environments.
|
 Platform Load Cell is designed for food industry.HBM, Inc.
Marlborough, MA 01752 3014
Aug 02, 2010
Platform load cell PW27 meets EHEDG guideline for applications in food sector and is available with maximum capacity of 20 kg. Product integrates overload stop that prevents it from being damaged if load is too great. Protected to IP68 and IP69K, cylindrical unit has no corners or edges, and features solid tubular housing that hermetically encapsulates measuring element with the strain gauges, which provides insensitivity to cleaning and disinfection agents used in food industry.
|
 I/O Link System connects RFID system to network. .Balluff, Inc.
Florence, KY 41042-0937
Aug 02, 2010
With IO-Link, users can connect complex devices, such as RFID processors, to industrial network via gateway using standard discrete wiring. Solution can replace I/O enclosure, 4 shielded cordsets, and 4-port RS232 PLC module with single IO-Link Expansion Module and four 3-conductor, non-shielded cordsets. Additional I/O points are made available by Expansion Module that can be used for analog devices, pressure sensors, or discrete sensors.
|
 Droplet Generation System delivers flexible, precise control.Dolomite Centre Ltd
Royston SG8 5TW United Kingdom
Aug 02, 2010
Developed for experienced researchers, modular Droplet Advanced System can produce over 10,000 monodispersed droplets per second with 20-250 µm dia. Flexible solution, featuring all required pumps, connectors, and chips, provides pulseless and stable liquid flow with 0-10 bar pressure range. Pressure-driven pumps and flow resistors enable precise control over flow rates and droplet size, and quick changes to flow conditions enable accelerated optimization of droplet parameters.
|
 Wireless-Enabled FRAM delivers Gen2 RFID access.Ramtron International Corp.
Colorado Springs, CO 80921
Aug 02, 2010
MaxArias(TM) wireless memory devices combine nonvolatile FRAM memory technology features with wireless access to enhance mobile data collection. Specifically, products offer up to 16 Kb nonvolatile FRAM memory with EPCglobal Class-1 Generation-2 UHF Air Interface Protocol Standard. Use with optimized antenna design enables power-up via energy harvested from RF field. Able to store up to 1,000 16-bit words of data, products operate over distances to 10 m at -13 dBm read/write sensitivity.
|
 High-Speed Beam Drill use 3 Siemens 25 hp spindles.Peddinghaus Corp.
Andrews, SC 29510
Aug 02, 2010
Supplied with Peddiflex3D CAD programming, batch nesting, and production reporting software, Advantage 2 is capable of drilling, tapping, countersinking, and multi-axis scribing for various profiles. It utilizes 3 drill spindles, each accompanied by optional 5-station automatic tool changer. Automatic tool changing, paired with carbide drilling up to 2,250 rpm and 27 ipm feed rates, result in profile capacities to 300 lb/ft. Complete electronic motion and spindle control is standard.
|
 Semiconductor Test Socket has modular design.Yamaichi Electronics U.S.A. Inc.
San Jose, CA 95134
Aug 02, 2010
Y-RED volume test socket features top side removable insert and tool-free cover mounting to minimize changeover times when testing semiconductors. Unit includes spring probe with crown plunger tip for BGA, and conical plunger tip for LGA and QFN packages. Its 2-piece pin has contact resistance below 50 mW and is stable for up to 500,000 mating cycles. Available for standard temperature range of -40 to +125°C, pin is also offered for temperature range of -55 to +150°C.
|
 Machine Guarding System complies with industry standards.WireCrafters Inc.
Louisville, KY 40214
Aug 02, 2010
Designed to exceed ANSI/OSHA, CSA, and EU 953 standards, modular RAPIDGUARD(TM) consists of framed panels, posts, and variety of door styles, including hinged and slide types. Panel's wires are welded at each intersection, then framed with 1¼ in. x 1¼ in. x 13 gauge angle. Furnished in standard system heights of 5, 6, and 8 ft, systems are available with options such as door interlocks, wire chases, polycarbonate and solid steel panels, as well as weld curtains.
|
 Rotary Encoders withstand extreme conditions.Advanced Micro Controls, Inc.
Terryville, CT 06786
Aug 02, 2010
Available with stainless steel housing and IP67 or IP69K rating, DuraCoders® are protected against high-pressure and high-temperature washdowns and liquid ingress from immersion in water or contaminants. Units come with 2.5 in. housing and double row sealed bearing. Offered in solid shaft and hub shaft models, encoders provide shaft loadings up to 100 lb radial and 50 lb axial. SSI, Digital, Analog, Incremental, DeviceNet, and Ethernet/IP versions are available.
|
 CNC Collet Chucks enable 10 second changes.Royal Products, Div. Curran Mfg. Corp.
Hauppauge, NY 11788
Aug 02, 2010
Available in capacities from 1 5/8 to 3 1/8 in., Quick-Grip(TM) CNC Collet Chucks are installed with tool that compresses rear end of collet so that it can be inserted. Upon expansion, collet locks into place via hook and groove arrangement. Each segment of collet is completely separated from other segments by vulcanized rubber spacer, enabling gripping range of 1/16 in. Additionally, units have full collapse range of 0.062 in.
|
 UHF Band VCO has -112 dBc/Hz at 10 KHz offset phase noise.Z-Communications, Inc.
San Diego, CA 92126
Aug 02, 2010
Model CLV0850A-LF VCO in UHF band operates at 850-851 MHz with tuning voltage range of 0.5-3.3 Vdc. Designed to deliver output power of 0 dBm at 3.3 Vdc supply while drawing 18 mA, it also features typical tuning sensitivity of 31 MHz/V and second harmonic suppression of -15 dBc. RoHS-compliant unit is contained in MINI-14S package measuring 0.5 x 0.5 x 0.22 in. and is suited for satellite communication and fixed wireless applications.
|
 Low Evaporation Plates eliminate well-to-well variability.Thermo Fisher Scientific
Waltham, MA 02454
Aug 02, 2010
Suited for cell-based arrays, Nunc(TM) Edge 96-well Plates incorporate large perimeter evaporative buffer zones that reduce overall plate evaporation rate to less than 2% after 7 days of incubation. Zones enable use of all 96 wells, minimizing edge effect. Prevention of cell death and toxicity in plates' outer wells allows results to remain true to population phenotype for high-throughput analysis. By eliminating occurrence of chromatic aberrations, flatness of plates optimizes automated imaging.
|
 Matrix Switchers integrate redundant power supplies.Crestron Electronics, Inc.
Rockleigh, NJ 07647
Aug 02, 2010
Model DM-MD8X8-RPS, 16X16-RPS, and 32X32-RPS DigitalMedia(TM) (DM) matrix switchers incorporate 1M hour MTBF redundant power supply. Card-based and field-configurable, these solutions deliver low-latency switching and pure, lossless distribution of HDMI(TM) and other signals. LEDs on front panel show status of each individual power supply. Devices are also available with remote monitoring and are suitable for broadcast environments and government applications.
|
 Absolute Pressure Transducers feature 3.86 mm face dia.Meggitt Sensing Systems (Endevco Corp.)
San Juan Capistrano, CA 92675
Aug 02, 2010
Weighing only 2.3 g, Endevco® model 8530B series transducers are offered in ranges of 200, 500, and 1,000 psia with 300 mV full scale output and resonant frequencies of 750 and 1,000 kHz. They include self-contained full hybrid temperature compensation, and feature active four-arm strain gauge bridge, diffused into sculpted silicon diaphragm for max sensitivity and wideband frequency response. Operating at -18 to 93°C, units are rugged to 20,000 g shock and min 4X burst pressure.
|
 Power Supplies feature linear regulation technology.Acopian Technical Co.
Easton, PA 18044
Aug 02, 2010
Infinity power supplies have line and load regulation of just 2 mV, and ripple is less than 0.25 mVrms, 0.75 mVp-p with low common mode noise. Rugged units come with outputs to 150 V and 150 W, with both 'slot' output voltage ranges and wide-adjust models that are adjustable from 0 to max rated output voltage, and can provide either constant voltage or current. Functional options include output programming, switching and monitoring, undervoltage alarms, and auxiliary outputs.
|
 M8 Panel-Mounted Receptacles have 3/4/6 gold plated contacts.Binder-USA, LP
Camarillo, CA 93012
Aug 02, 2010
Panel-mounted receptacles of M8 connectors are available in PCB mountable and prewired versions. Prewired versions have crimped leads and come in front- and rear-mounted housings, while PCB-mountable versions feature straight or right-angle PCB pins and shielding sheet for mounting onto printed circuit boards. Units are mating-compatible with all M8 field-attachable connectors and cordsets.
|
 Low Pressure Sensor comes with I2C or SPI digital interface.Servoflo Corp.
Lexington, MA 02421
Aug 02, 2010
Low pressure sensor, MS5701 measures as low as ±2.5 to ±10 in. H2O in differential version, and from +2-20 in. H2O in gauge version. I2C or SPI interface communicates up to 20 MHz. Utilizing MEMS technology, unit offers low supply voltage of 1.8-3.6 V with 1 mA power consumption. It has resolution of 0.0004 in. of water and conversion of 0.54 msec, and operates in temperature range of -20 to 85°C.
|
 Hydraulic Hand Pump delivers up to 15,000 psi of pressure.E Instruments International LLC
Langhorne, PA 19047
Aug 02, 2010
Hydraulic hand pump HHP 1000 includes transparent fluid chamber reservoir for viewing of fluid levels, fine adjustment vernier, pressure release valve, high/low selection knob stroke adjustment, and scissor action pump. Optional features included are hydraulic hose with fitting, carrying case for pumps, hoses and adaptors, and up to 5 set of adaptors.
|
(Showing headlines 25131 - 25150) << 1257 1258 1259 1260 1261 1262 1263 1264 1265 1266 1267 1268 1269 1270 1271 1272 1273 1274 1275 1276 1277 1278 1279 1280 1281 1282 1283 1284 1285 1286 1287 1288 1289 1290 1291 1292 1293 1294 1295 1296 1297 1298 1299 1300 1301 1302 1303 1304 1305 1306 1307 1308 1309 1310 1311 1312 1313 1314 1315 1316 1317 1318 1319 1320 1321 1322 1323 1324 1325 1326 1327 1328 1329 1330 1331 1332 1333 1334 1335 1336 1337 1338 1339 1340 1341 1342 1343 1344 1345 1346 1347 1348 1349 1350 1351 1352 1353 1354 1355 1356 1357 1358 1359 1360 1361 1362 1363 1364 1365 1366 1367 1368 1369 1370 1371 1372 1373 1374 1375 1376 1377 1378 1379 1380 1381 1382 1383 1384 1385 1386 1387 1388 1389 1390 1391 1392 1393 1394 1395 1396 1397 1398 1399 1400 1401 1402 1403 1404 1405 1406 1407 1408 1409 1410 1411 1412 1413 1414 1415 1416 1417 1418 1419 1420 1421 1422 1423 1424 1425 1426 1427 1428 1429 1430 1431 1432 1433 1434 1435 1436 1437 1438 1439 1440 1441 1442 1443 1444 1445 1446 1447 1448 1449 1450 1451 1452 1453 1454 1455 1456 1457 1458 1459 1460 1461 1462 1463 1464 1465 1466 1467 1468 1469 1470 1471 1472 1473 1474 1475 1476 1477 1478 1479 1480 1481 1482 1483 1484 1485 1486 1487 1488 1489 1490 1491 1492 1493 1494 1495 1496 1497 1498 1499 1500 1501 1502 1503 1504 1505 1506 1507 1508 1509 1510 1511 1512 1513 1514 1515 1516 1517 1518 1519 1520 1521 1522 1523 1524 1525 1526 1527 1528 1529 1530 1531 1532 1533 1534 1535 1536 1537 1538 1539 1540 1541 1542 1543 1544 1545 1546 1547 1548 1549 1550 1551 1552 1553 1554 1555 1556 1557 1558 1559 1560 1561 1562 1563 1564 1565 1566 1567 1568 1569 1570 1571 1572 1573 1574 1575 1576 1577 1578 1579 1580 1581 1582 1583 1584 1585 1586 1587 1588 1589 1590 1591 1592 1593 1594 1595 1596 1597 1598 1599 1600 1601 1602 1603 1604 1605 1606 1607 1608 1609 1610 1611 1612 1613 1614 1615 1616 1617 1618 1619 1620 1621 1622 1623 1624 1625 1626 1627 1628 1629 1630 1631 1632 1633 1634 1635 1636 1637 1638 1639 1640 1641 1642 1643 1644 1645 1646 1647 1648 1649 1650 1651 1652 1653 1654 1655 1656 ...
|
|
|