|
|
|
Laboratory and Research Supplies and Equipment ->
Other
Other
(Showing headlines 41 - 60) << 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 ...
|
Kit isolates DNA from food cultured microorganisms.MO BIO Laboratories, Inc.
Carlsbad, CA 92010
Jul 24, 2009
PowerFood(TM) Microbial DNA Isolation Kit is designed to isolate high-quality genomic DNA from food cultured microorganisms. It incorporates Inhibitor Removal Technology to remove PCR-inhibiting compounds associated with food cultures, such as lipids and polysaccharides. High-quality, inhibitor-free DNA is then provided for use in downstream applications including PCR, qPCR, and genotyping assays.
|
 Metrology System improves fab productivity.Rudolph Technologies, Inc.
Flanders, NJ 07836
Jul 22, 2009
Built on Vanguard-II automation platform, S3000S(TM) is suited for in-line process control of advanced diffusion and fab-wide thin film applications. Optical design enables simultaneous measurement with multi-wavelength, multi-angle Focus Beam Ellipsometry and deep ultraviolet reflectometry, minimizing measurement time and optimizing throughput. Optional MAControl(TM) module enables one-step, uniform, non-destructive removal of molecular airborne contamination layer on thin films.
|
Metrology System is suited for inspection of washed panels.Dark Field
Shelton, CT 06484
Jul 16, 2009
Employing dark field optics that detect defects smaller than an optical pixel, NxtGen(TM)-Wash performs all functions 100% on-line and in real-time. It detects float glass defects, edge chips/cracks, and broken corners/flairs as well as TCO coating defects and washer residue. System also measures panel width, length, and squareness as well as thickness and warp. Supporting range of optical modules, system can capture and analyze 500+ million pixels in 3 sec.
|
 Nitrogen Evaporator suits drug development applications.Organomation Associates, Inc.
Berlin, MA 01503
Jul 14, 2009
Accommodating three 96-well microtiter plates simultaneously, MICROVAP(TM) 3 Nitrogen Evaporator provides one 2 in. long 19 Ga needle centered over each sample well. It features individually controlled manifolds for nitrogen and temperature, and consumes 20-30 Lpm of nitrogen per plate. Capable of evaporating up to 50 plates per day, device suits high volume pharmaceutical applications. Unit has 250 W heater for each plate with electronic temperature controller from ambient to 100°C.
|
Vaporizer handles all liquid-to-vapor applications.Brooks Instrument
Hatfield, PA 19440
Jul 14, 2009
Employing heated gas for liquid vaporization, DLI vaporizer delivers chemically pure vapor that is free of decomposition byproducts or liquid carry-over. Vaporizer can accept multiple liquid inlets and generate mixed vapors. Unit is available in designs to accommodate wide range of liquid properties such as low vapor pressures (sub 1 Torr), low flow rates (sub 5 g/hr), and high flow rates (more than 15 kg/hr). Product is offered as fully integrated system or as individual components.
|
 Anesthesia System is designed for research laboratories.Harvard Apparatus, Inc.
Holliston, MA 01746 1371
Jul 10, 2009
Available with 2, 4, or 6 individually controlled stations in single unit, multi-station anesthesia system is suited for rodent and small animal anesthesia. Each station can deliver different percentage of anesthetic agent as needed, without affecting other stations. Rodent circuit, mask, and diaphragm system ensure safe and effective anesthetic agent delivery.
|
Workstation automates protein sample preparation/analysis.Caliper Life Sciences, Inc.
Hopkinton, MA 01748
Jul 10, 2009
Staccato Protein Workstation is designed to address bottlenecks in characterization of biological therapeutics and biogenerics according to requirements of QbD approaches. It incorporates Sciclone ALH 3000 for automated liquid handling, Twister II for microplate handling, and LabChip GXII, which analyzes protein size, concentration, and purity for microfluidic protein characterization. Various accessories for workflow automation are also included.
|
 Laboratory Storage Box is made of polycarbonate.Dynalab Corp.
Rochester, NY 14623
Jul 08, 2009
Featuring transparent hinged removable PC cover, Polycarbonate Safety Centrifuge Tube Rack and Box protects samples from dust or frost and handles temperatures from -130 to +130°C. It includes 2 PC racks with alpha numeric grid to hold 20 x 15 mL or 12 x 50 mL tubes. Compact and stackable box has draining holes in bottom for use in water bath.
|
Bench Reactor Stand Assembly fits into most laboratory hoods.Ace Glass, Inc.
Vineland, NJ 08362
Jul 08, 2009
With adjustable bottom plate, motor mount, and middle flask supports, Bench Reactor Stand Assembly accommodates all types of glass bench reactors from 1-6 L having overhead drive motors, and in both jacketed and non-jacketed flask versions. It comes completely assembled and can be taken apart for cleaning. Open bottom accommodates round-bottom and flat-bottom flasks, and even flasks with bottom valves.
|
 Chromatographic Systems maximize laboratory productivity.Thermo Fisher Scientific
Waltham, MA 02454
Jul 01, 2009
Accela 600 HPLC provides flow rates up to 5 mL/min and maximum operating pressure of 600 bar with 90 µL delay volume. It is designed for Hypersil columns packed with 5, 3, and 2.4 micron particles. Suited for U-HPLC applications using columns with sub 2.0 micron particles, Accela 1000 has maximum operating pressure of 1,000 bar with 65 µL delay volume. Both feature quaternary solvent delivery system and Force Feedback Control for optimized compositional and flow rate accuracy.
|
Bright Light Fixture allows expanded incubator applications.Caron Products & Services, Inc.
Marietta, OH 45750 0715
Jun 30, 2009
Optimized for light transmission with minimal heat generation, expandable and waterproof gLux(TM) features modular and adjustable light banks that let users fill incubator with general or direct lighting of various intensities. This energy-efficient, high-output lighting system comes standard in 10 and 25 ft³ Diurnal Incubators or is available as accessory for all other 10 and 25 ft³ products as accessory number LGHT301 or LGHT303.
|
 Bottletop Burette features Class A precision.BrandTech Scientific, Inc.
Essex, CT 06426
Jun 26, 2009
Titrette® bottletop burette provides titration within ASTM and ISO error limits for Class A glass burettes. Magnetoresistive measurement system detects actual piston rod movement and unit automatically detects direction of rotation for seamless transition between filling/dispensing. Suited for concentrations up to 1 mol/L, it has recirculation valve to simplify priming and digital display to eliminate meniscus reading errors. Compact instrument mounts directly on most titrant bottles.
|
 Metrology Systems characterize flat panel displays.Lehighton Electronics, Inc.
Lehighton, PA 18235
Jun 10, 2009
Implementing sensor heads for in-line product monitoring, 1800 Series offers fully automated conveyor models to monitor uniformity of ITO, TCO, thin films, and other coatings on non-conductive substrates. Optional SPC software gives warning when uniformity or sheet-resistance measurements are out of range. With automatic Z-function sensor head, 1800AG Model offers automatic gap adjustment. R/D Series is suited for characterization of wafers up to 450 mm dia, coated glass panels, and solar cells.
|
Carousel enables flame sterilizing of inoculation loops.WLD-TEC Gmbh
Arenshausen Germany
Jun 10, 2009
Fabricated of stainless steel and anodized aluminum with display protected by heat-resistant glass, AutoloopPRO withstands extreme laboratory conditions and is suitable for up to 4 inoculation loops. Unit rotates and controls flaming automatically, and when flaming is completed, display shows remaining cooling time and removal positions of cool inoculation loops. In addition, intelligent sensor monitors safe sterilization.
|
X-Ray Image Detector suits angiography equipment.Varian Medical Systems, Inc.
Palo Alto, CA 94304
Jun 09, 2009
Operating at speeds up to 30 fps, PaxScan® 3030+ lets physicians monitor interventional procedures, including placement of catheters within blood vessels, in real-time. Multi-modality panel is also designed for use in cardiovascular imaging systems and surgical C-arms. While 194 micron pixel pitch results in images with enhanced contrast resolution and no distortion, cesium iodide scintillator optimized for scanning at 40-150 kV minimizes X-ray dose to patient.
|
 Automatic Carrousel flame sterilizes inoculation loops.WLD-TEC Gmbh
Arenshausen Germany
Jun 08, 2009
With stable housing and removal positions on both sides suited for right and left handers, AutoloopPRO accommodates up to 4 inoculation loops and rotates/controls flaming automatically. Flaming and cooling time can be adjusted to the second, while intelligent sensor monitors safe sterilization. When flaming is completed, fully graphic display shows remaining cooling time and removal positions of cool inoculation loops, preventing unintentional use of hot inoculation loops.
|
 Fur Removal Clippers are designed for small animals.Harvard Apparatus, Inc.
Holliston, MA 01746 1371
Jun 05, 2009
Made for research applications, small animal Fur Removal Clippers are available in wide range of models featuring multiple speeds and numerous blade sizes. Compact and lightweight clippers are offered in corded and cordless versions. For dander free animal fur clipping, vacuum clipper system is also available.
|
Machine destroys microscope slides and their labels.S & G Enterprises, Inc.
Germantown, WI 53022
Jun 05, 2009
Able to destroy approximately 10,000 slides/hr, SLYDEATER(TM) Slide Destruction System creates unrecognizable mound of glass dust that can be tossed into regular trash, creating instant HIPAA compliance. Operator loads as many as 300-400 slides into chute at once, they are then pulverized with 2-step crushing system and automatically deposited into no-tape collection box with integrated locking lid. Flashing indicator light notifies operator when box is full.
|
 Medical Ventilator is designed for mice.Harvard Apparatus, Inc.
Holliston, MA 01746 1371
Jun 01, 2009
Suitable for any animal with tidal volumes of 30-350 µL and respiratory rates of 60-400 breaths/min, MiniVent features rod clamp that allows it to be positioned directly next to animal. Ventilator employs valveless rotary plunger that eliminates clogging during ventilation cycle. Inspiration and expiration is controlled by synchronized forward and rotating movement of cylinder and plunger. Compact and lightweight unit reduces tidal volume error due to system compliance to 3 µL.
|
Susceptibility Plates serve in-vitro diagnostics, research.Trek Diagnostic Systems, Inc.
Cleveland, OH 44131
Jun 01, 2009
Designed for in-vitro diagnostics, YeastOne susceptibility plate is FDA-cleared for testing Candida species isolates against 4 antifungal agents: voriconazole, fluconazole, 5-flucytosine, and itraconazole. It features 24 hr incubation, colorimetric endpoints, and on-scale QC ranges. Available for research use, Sensititre® Xtra Gram Negative MIC plate incorporates 21 antimicrobic compounds. These include doripenem, colistin, polymixin B, doxycycline, minocycline, ertapenem, and imipenem.
|
(Showing headlines 41 - 60) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38
|
|
|
|
 |
ThomasNet News Advertisers
|
 |
|