 Orbital Shaker accommodates different size vessels.SciLabware (formerly Barloworld Scientific)
Staffordshire ST15 0SA United Kingdom
Aug 17, 2006
Providing orbit of 16 mm and speed range of 30-300 rpm, SSL1 Labscale Orbital Shaker has fully adjustable cradle system that holds 12 x 250, 8 x 500, 6 x 1,000, or 2 x 2,000 ml Erlenmeyer flasks or bottles. Shaker features 355 x 355 mm platform, 4-40°C operational temperature range, and 120 V, 60 Hz electrical supply. Microprocessor-controlled speed is fully variable, set digitally, and built-in timer allows shaking times from 1-999 min.
|
Labels and Conjugates enable life science research.Evident Technologies
Troy, NY 12180
Aug 15, 2006
Featuring Molecular Plating, T2-MP EviTags are quantum dot-based, conjugation-ready fluorescent labels available with either amine or carboxyl terminal groups or with non-functional bioactive surface. EviFluors(TM) are ready-to-use, activated quantum dot conjugates coupled to secondary antibodies and other proteins. Physical properties enable creation of research tools and diagnostics for in vivo and in vitro applications.
|
No-Wash Calcium Flux Assay is designed for GPCR screening.Molecular Devices Corp.
Sunnyvale, CA 94089-1136
Aug 15, 2006
Using homogenous mix-and-read, no-wash protocols, FLIPR Calcium 4 Assay Kit provides screening technique for GPCRs in pharmaceutical drug discovery. It includes masking technology and detects intracellular calcium flux from different cell types and receptors. Kits offer different formulations to address broad range of targets, including chemokines, small peptides, and transient, endogenous, and low-expression receptors.
|
 Sealing Foils are designed for PCR and cold storage.Excel Scientific Inc
Wrightwood, CA 92397
Aug 14, 2006
AlumaSeal 96(TM) and AlumaSeal 384(TM) Aluminum Foils feature single-tab-design for protecting samples in microplates during polymerase chain reaction (PCR) gene amplification or cold storage. Pierceable by pipette tips or robotic probes, foil and adhesives tolerate temperatures from -80 to +150°C. AlumaSeal 96 is designed to fit inside raised-rim plates, and both foils are certified free of DNase, RNase, and nucleic acid.
|
Metrology System measures ultra thin films.Rudolph Technologies, Inc.
Flanders, NJ 07836
Aug 14, 2006
Combining PULSE Technology(TM) with MMXRF technology on single platform, Synergy MPX(TM) System measures ultra thin opaque films, such as ALD layers. PULSE Technology consists of picosecond ultrasonic laser sonar technique that provides non-contact, non-destructive opaque film measurements from 40 angstroms to 6 µm. Monochromatic source eliminates virtually all background radiation, while microspot permits measurements in scribe line test structures on product wafers.
|
 Tube Drive safely disperses and homogenizes harmful samples.IKA Works, Inc.
Wilmington, NC 28405-7419
Aug 10, 2006
Accommodating 2-15 mL hermetically sealable disposable sample tubes, ULTRA-TURRAX® Tube Drive offers protection and security for infectious sample materials, toxic, and high-odor substances. Single drive unit can safely disperse, stir, and grind, with no possibility of cross-contamination. Device can be used individually, or configured in series, for applications in medicine, diagnostic laboratories, food testing, and research.
|
 Blood Tube Rotators feature adjustable mixing angle.SciLabware (formerly Barloworld Scientific)
Staffordshire ST15 0SA United Kingdom
Aug 10, 2006
Stuart SB2 Blood Tube Rotators operate at fixed speed of 20 rpm and accommodate tube holders for end-over-end and rotational mixing of centrifuge tubes, microcentrifuge tubes, test tubes, and blood tubes. Angle of tilt is fully adjustable, and rotators can be used in incubators up to 60°C and in cold rooms down to 4°C. Device includes on/off switch and spillage tray, and provides gentle mixing for life sciences applications such as keeping blood samples in suspension.
|
Focused Ion Beam System provides circuit edit platform.FEI Co.
Hillsboro, OR 97124-5830
Aug 10, 2006
Model V600FIB Focused Ion Beam system is offered for debug, failure analysis, and sample preparation for semiconductor devices down to 90 nm, with upgrade path for circuit edit applications for designs below 65 nm. With Sidewinder(TM) 30 kV ion column, application-specific gas delivery system, and 5-axis tilt stage for stable cross sectioning for failure analysis applications, system accommodates variety of samples, from packaged parts to 8 in. wafers.
|
 Faraday Cages are suited for vibration-isolation units.Kinetic Systems, Inc.
Boston, MA 02131
Aug 07, 2006
Faraday Cage/Darkbox utilizes solid, electrically continuous aluminum walls to protect sensitive devices from electrical and magnetic interference while also eliminating light and attenuating acoustic noise. Workstation Faraday Cages, built with high-density, 16-mesh copper screen, can be customized with 2 hinged front doors, roll-up door, or sliding doors. Both models can be configured with fixed, hanging, or sliding shelves; monitor stands; electrical outlet strips; and lighting.
|
 Laboratory Balances suit precision weighing applications.Sartorius Corp.
Edgewood, NY 11717 8315
Aug 04, 2006
Comprised of 28 models with capacities from 0.1 mg to 34 kg, LA Reference series is designed with monolithic weigh cell and microprocessor control. Products include 14 application programs and can store up to 50 ISO/GLP-compliant test records. Also included, isoCAL feature enables fully automatic calibration and adjustment functions at regular or programmed intervals. Flexible display and control unit can be separated for remote control of weighing process.
|
 Injector is suited for HPLC applications.VICI Valco Instrument Co., Inc.
Houston, TX 77255
Aug 02, 2006
C72 Ultra-high Pressure UHPLC Injector incorporates proprietary stator coating that permits pressures to 15,000 or 20,000 psi. Computer control is facilitated via RS-232 or RS-485 interface, but injector can also be controlled manually. CE-certified device includes autosensing 110/230 Vac to 24 Vdc universal power supply. Available in 4, 6, 8, and 10 port configurations, device includes choice of .004, .006, or .010 in. bore.
|
 See-Saw Rocker provides gentle mixing in lab vessels.SciLabware (formerly Barloworld Scientific)
Staffordshire ST15 0SA United Kingdom
Jul 27, 2006
Model SSM4 mini see-saw rocker provides a rocking action that creates wave motion within vessels such as culture flasks and Petri dishes. Digital selection of speed and time allows for accurate and reproducible conditions. Parameters are set via encoder control knob and are visible on LED display. With non-slip mat to hold flat based vessels in place during mixing, magnetic accessory tier system can be added to triple available space.
|
 Laboratory Presses perform compression molding of parts.TMP, Technical Machine Products
Cleveland, OH 44102 4431
Jul 25, 2006
Suited for molding rubber, silicone, and composite products, Techni-Mold(TM) hydraulic compression laboratory presses are available as TMLV (Vacuum) Series with CPS advanced controls or TML (Non-Vacuum) Series with BPS basic controls. Both series contain 10 standard models, rated from 12-100 tons, with platen sizes from 6-16 in.². Custom models are also available, as are options ranging from water-cooled platens to variety of shuttle designs.
|
 Roller Mixer is suitable for mixing blood samples.SciLabware (formerly Barloworld Scientific)
Staffordshire ST15 0SA United Kingdom
Jul 24, 2006
SRT1 Roller Mixer features 5 rollers that rotate at 33 rpm and rise and fall 16 mm. Rollers are 340 x 30 mm and can load 22 lb maximum. Units can be used in incubators up to 60ºC, humidity to 80%, or in cold rooms down to 4ºC. Suited for mixing viscous substances and liquid-solid suspensions where minimum aeration is required. Stainless steel drip tray collects accidental spillages. For bottles up to 135 mm dia, one or more rollers can be removed for improved grip.
|
 HPLC Column Packer has compact design.Novasep, Inc.
Boothwyn, PA 19061
Jul 21, 2006
Pack-n-Sep(TM) 50 combines advantages of 2-in. ID Dynamic Axial Compression (DAC) column and device capable of packing multiple columns that can be used separately with HPLC, SMB, or Varicol® systems. Preparative HPLC column is suited for purification of grams to hundreds of grams, and unit packs beds up to 10 in. in 13 in. long column. System attaches to packer in DAC mode or can be used separately in non-DAC mode.
|
 Gyratory Rockers accommodate number of samples.SciLabware (formerly Barloworld Scientific)
Staffordshire ST15 0SA United Kingdom
Jul 18, 2006
Suited for multiple users, SSL3 Labscale Gyratory Rockers feature max platform dimensions of 14 x 14 in. with speed range of 5-70 rpm and max load of 22 lb. Angle of tilt is adjustable by hand from 7-12°. Supplied with non-slip mat, units operate in temperatures up to 40°C and humidity up to 80%. Providing digital selection of speed and time, rockers are suited for low foaming agitation, DNA extractions, staining and de-staining procedures.
|
 Amplification System provides terawatt peak power.Del Mar Photonics, Inc.
San Diego, CA 92130
Jul 17, 2006
Equipped with Ti:sapphire oscillator, Cortes-800 consists of 3 chirped pulse amplification stages on single optical table. It achieves pulse energies greater than 1.5 J before compression in vacuum chamber. Active feedback and pulse shaping allow unit to produce sub 30 fs output pulses with peak powers greater than 40 terawatts. Wavelength is 795-820 nm at repetition rate of 10 ±0.5 Hz. Timing and control software make unit suited for study of high-energy laser-matter interaction.
|
Metrology Tools measure thin transparent films.Rudolph Technologies, Inc.
Flanders, NJ 07836
Jul 10, 2006
Utilizing FOCUS(TM) beam ellipsometry, S3000(TM) (300 mm) and S2000(TM) (200 mm) measure transparent films throughout device fabrication process. Laser light sources are used for optimal accuracy, stability, spot size, and tool-to-tool matching. Also provided, optional deep UV and visible reflectometry capabilities offer flexibility in addressing various applications throughout fabrication. Built on Vanguard(TM) platform, products incorporate Cognex® PatMAX® geometric pattern-matching technology.
|
Content Screening Readers can run live-cell kinetic assays.Cellomics, Inc.
Pittsburgh, PA 15219
Jun 29, 2006
ArrayScan® VTI High-Content Screening (HCS) Reader is available with VTI Live module option, which enables users to run automated live-cell kinetic assays. In addition to incubation chamber used to maintain controlled environment for cells under study, module offers kinetics software that automatically extracts and analyzes images and data from experiments over course of time. Incubation chamber features configurable temperature, CO2, and humidity controls.
|
 Microscope is suited for education and laboratory use.Carl Zeiss Microimaging, Inc.
Thornwood, NY 10594-1939
Jun 28, 2006
Offered in 10 configurations, Primo Star features modular illumination with 30 W halogen bulb, LED, or tilting mirror. Control display on both sides of stand provides information about light intensity of microscope, and external arrangement of power supply unit in rear panel ensures tidy stowing of supply cable. Features include ergonomic 30° viewing angle, variable interocular distance of 48-75 mm, course focus with friction control, and fine focus with jog/shuttle knob.
|