ThomasNet News Logo
Sign Up | Log In | ThomasNet Home | Promote Your Business
 Journals
Industry Market Trends ®
IMT Career Journal
IMT Fluid & Gas Flow Journal
IMT Green & Clean Journal
IMT Machining Journal
IMT Procurement Journal
 Industry News
Latest New Product News
Association & Government News
 Product News
Adhesives and Sealants
Agricultural and Farming Products
Architectural and Civil Engineering Products
Automatic ID
Chemical Processing and Waste Management
Cleaning Products and Equipment
Communication Systems and Equipment
Computer Hardware and Peripherals
Construction Equipment and Supplies
Controls and Controllers
Display and Presentation Equipment
Electrical Equipment and Systems
Electronic Components and Devices
Explosives, Armaments and Weaponry
Fasteners and Hardware
Fluid and Gas Flow Equipment
Food Processing and Preparation
Green & Clean
Health, Medical and Dental Supplies and Equipment
HVAC
Labels, Tags, Signage and Equipment
Laboratory and Research Supplies and Equipment
Lubricants
Machinery and Machining Tools
Material Handling and Storage
Materials and Material Processing
Mechanical Components and Assemblies
Mechanical Power Transmission
Mining, Oil Drilling & Refining
Mounting and Attaching Products
Non-Industrial Products
Optics and Photonics
Packaging Products & Equipment
Paints and Coatings
Plant Furnishings and Accessories
Portable Tools
Printing and Duplicating Equipment
Retail and Sales Equipment
Robotics
Safety and Security Equipment
Sensors, Monitors and Transducers
Services
Software
Test and Measuring Instruments
Textile Industry Products
Thermal and Heating Equipment
Timers and Clocks
Transportation Industry Products
Vision Systems
Waste Handling Equipment
Welding Equipment and Supplies
 Press Releases
Products in the News
Company News
Mergers & Acquisitions
People in the News
Literature & Websites
 Resources
News Delivery Options
FABTECH
Society of Manufacturing Engineers
Browse Categories
Browse Companies
Mobile Edition
PR Resources
Licensing
Advertising
How to Write an effective Press Release
Trade Associations
Small Business Support
MEP
Laboratory and Research Supplies & Equipment




(Showing headlines 121 - 140)   << 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 ...

DLS Plate Reader includes on-board camera.

Wyatt Technology    Santa Barbara, CA 93117
Jul 05, 2012 With on-board camera, DynaPro Plate Reader II collects clean images of each well and provides valuable insight into optimal conditions for each sample. System offers expanded temperature range, enabling measurements from 4-85°C for flexibility in protein melting and aggregation analyses. Compatible with hundreds of industry-standard well plates in 96,384 or 1,536 well formats, DynaPro II is suited for crystallography, vaccine development, compound aggregation, and nanoparticle characterization.

Single-Use Bioreactor handles volumes from 4-10 L.

Xcellerex, Inc    Marlborough, MA 01752
Jun 29, 2012 Available in single-, twin-, triplet-, and quad-vessel configurations, Model XDR(TM)-10 is suitable for GMP clinical and commercial manufacture of biotherapeutics, vaccines, and other biologics. Bag-type benchtop unit features low shear impeller, which provides gentle mixing for sensitive cells or media. Bioreactor can function as production vessel, or become scale-down tool or satellite platform for larger projects to be continued in larger bioreactors.

Triple Quadrupole GC/MS is optimized for sensitivity.

Shimadzu Scientific    Columbia, MD 21046
Jun 26, 2012 Triple quadrupole gas chromatograph mass spectrometer (GC/MS), GCMS-TQ8030, employs ion source that promotes sensitivity for multiple reaction monitoring (MRM) measurements by GC/MS/MS as well as for scan and SIM measurements by GC/MS. Analysis allows variety of measurement modes, including MRM, scan, combination scan/MRM, neutral loss scan, and others. Scan speeds of up to 20,000 microns/sec and MRM measurements up to 600 transitions/sec are facilitated by UFsweeper® technology.

Antimicrobial targets meat processing applications.

Albemarle Corp.    Baton Rouge, LA 70820
Jun 25, 2012 CellVex(TM) Post-Harvest Antimicrobial, a liquid form of hypobromous acid, is proven effective against E. coli, Campylobacter, and Salmonella for high volume applications in meat and poultry markets. Product is FDA approved and can be used as part of multiple intervention strategy in variety of meat processing applications.

Tabletop Centrifuge meets diverse separation requirements.

Tabletop Centrifuge meets diverse separation requirements.

Beckman Coulter, Inc.    Fullerton, CA 92834-3100
Jun 22, 2012 Operating at less than 47 dBa, Optima MAX-TL tabletop ultracentrifuge has 120,000 rpm max speed and 657,000 x g max rcf. Entry-level instrument lets users set multiple programs of up to 5 steps each using color LCD touchscreen, which is accessible in 9 languages and offers context-sensitive onscreen help. While speed can be controlled within ±50 rpm of set point, temperatures can be set from 0° to +40°C in 1°C increments and controlled within ±2°C of set point.

Wafer Vacuum Handling System accommodates variety of parts.

Virtual Industries, Inc.    Colorado Springs, CO 80915
Jun 13, 2012 Used for handling wafers and solar cells, WV-9000 WAFER-VAC System does not require any in-house air plumbing and plugs directly into 110 V, 50/60 Hz supply. General-purpose tool has diaphragm vacuum pump that generates up to 10 in. Hg with open air flow of 2.3 lpm. ESD-safe unit is also Class 100 Clean room safe and connects to ground automatically with 3-wire power cord. Illuminated on/off switch, pushbutton wafer tip pen, and 6 ft clear coiled vacuum hose come standard.

Six-Axis Articulated Robots target cleanroom applications.

DENSO Corp.    Aichi 448-8661  Japan
Jun 08, 2012 Available in ISO 5 cleanroom versions, VS-Series offers 500-900 mm reach and payload capacities from 4-7 kg with cycles times from 0.37-0.33 sec and repeatability from ±0.03 to ±0.02 mm. Internal wiring option allows connection of Gigabit Ethernet devices and servo grippers directly to robot flange, preventing cables from becoming tangled or interfering with peripheral equipment. Robots can be mounted on floor, ceiling, or wall with no special hardware needed.

Cell Monitor enables automated electric field manipulation.

Cellectricon AB    Goteborg 412 50  Sweden
Jun 07, 2012 Cellaxess® Elektra Discovery Platform enables in-situ manipulation and monitoring of cell cultures directly in HCA-compatible, 96- and 384-well microplates at any cellular developmental stage with completely retained cellular morphology. Able to be applied to range of cellular manipulations in cell biology research, platform supports imaging-based microplate reader for recording of transient fluorescence and luminescence signals from living cells.

Ultra-Hi-Res X-Ray/CT System looks into small and medium objects.

Ultra-Hi-Res X-Ray/CT System looks into small and medium objects.

North Star Imaging, Inc.    Rogers, MN 55374
Jun 06, 2012 Housing 5-axis manipulator with vibration isolation system, X25 digital x-ray and CT system is suited for submicron resolution imaging and accurate scanning. Unit provides 9 x 9 in. scanning envelope and rotational stage capable of handling up to 25 lb. X-ray voltage range is 10-160 kV, max system resolution is less than 0.5 µm, and geometric magnification is up to 4,000X. With z-axis of 1,003 mm and rotation of 360º continuous, max scan travel is 228 mm vertical and 152 mm horizontal.

Hi-Res Mass Spectrometer offers GCxGC capabilities.

Leco Corp.    St. Joseph, MI 49085 2396
Jun 06, 2012 Allowing resolutions up to 50,000 FWHM, Folded Flight Path(TM) (FFP(TM)) TOFMS technology is available with 2D gas chromatography (GCxGC) capabilities that increase information obtained with every sample analysis. Technology is capable of achieving acquisition rates up to 200 spectra/sec, providing for fully resolved narrow GCxGC peaks, while ChromaTOF-HRT® software utilizes True Signal Deconvolution® for peak identification, seamless data handling, and compatibility with NIST library.

Pulsed EI Ionization Source enhances spectrometer sensitivity.

Leco Corp.    St. Joseph, MI 49085 2396
Jun 06, 2012 Pegasus® GC-HRT supports pulsed Electron Impact (EI) ionization source as add-on option. Improving instrument sensitivity by one order of magnitude (from 1,000 fg to 100 fg), option lets scientists performing dioxin analysis meet/exceed requirements in methodology from U.S. EPA. Pegasus GC-HRT also enables acquisition of spectral data across range without sacrificing resolving power or mass accuracy, while ChromaTOF-HRT® software utilizes True Signal Deconvolution®.

Texture Analyzer supports mucoadhesion evaluation.

Texture Analyzer supports mucoadhesion evaluation.

Brookfield Engineering Laboratories, Inc.    Middleboro, MA 02346
Jun 05, 2012 With TA-MA Mucoadhesion Test Fixture, CT3 Tester enables technician to evaluate mucoadhesion of tablets and capsules to stomach wall and intestinal lining in humans and animals. This lends to being able to verify delivery of proper dosage for each patient. Intended for use by pharmaceutical and medical industries, stand-alone instrument operates in compression and tension modes. Included software offers range of test modes, enabling technician to automatically generate analytical data.

Microscope XY Stage utilizes ceramic linear motors.

Microscope XY Stage utilizes ceramic linear motors.

Physik Instrumente (PI)    Auburn, MA 01501
May 31, 2012 Delivered as complete system including controller, joystick, and software, Model M-687 is available in versions for Olympus IX2 and Nikon Eclipse Ti inverted microscopes. Unit features travel range up to 135 x 85 mm and speeds up to 120 mm/sec. Self-clamping ceramic linear motors provide positional stability, while linear encoders with 100 nm resolution deliver direct position feedback to controller, allowing accurate closed-loop operation.

LC/MS Grade Reagents  have ultrapure formulation.

LC/MS Grade Reagents have ultrapure formulation.

Thermo Fisher Scientific    Waltham, MA 02454
May 24, 2012 Chemical Optima® liquid chromatography/mass spectrometry (LC/MS) grade reagents modify mobile phase to minimize background noise and enhance MS detection. Designed for use with existing ultrapure Optima LC/MS solvent range, low ionic content reagents, comprising ammonium formate, ammonium acetate and acetic acid, improve chromatographic peak shape and provide stable analyte signals in MS detector, and are available in variety of pack sizes.

Form Measuring Systems handle workpieces up to 40 kg.

Form Measuring Systems handle workpieces up to 40 kg.

Jenoptik Laser Technologies USA Corp.    Brighton, MI 48116
May 24, 2012 Designed for workpieces up to 430 mm in diameter, Hommel-Etamic F435 and F455 complete fully automatic measurement of geometrical tolerances, surface roughness, and straightness in single setup. Advanced probe design permits roughness and waviness inspections along with form and position tolerance measurements via adjustment on rotary control. With CNC rotation and tilt module, fully automatic axial and radial measurements are performed without interruption.

Hot Plate and Stirrer feature 5 or 9 positions.

Hot Plate and Stirrer feature 5 or 9 positions.

Torrey Pines Scientific, Inc.    Carlsbad, CA 92010
May 23, 2012 With large 12 in. square ceramic heater tops offering temperature range to 400°C, Model ST15/HS15 can stir five 800 ml beakers, while ST19/HS19 units can stir nine 500 ml beakers of aqueous solutions. Stirring range is from 100-1,500 rpm. All controls are mounted in front of heater surface to protect against accidental burns and are designed to keep spills out of chassis. Units are available in 100 Vac/50Hz, 115 Vac/60Hz, 220 Vac/60Hz and 230 Vac/50Hz.

Hot-Wire Thermo-Anemometer comes in rugged, compact housing.

Hot-Wire Thermo-Anemometer comes in rugged, compact housing.

E Instruments International LLC    Langhorne, PA 19047
May 16, 2012 Supplied in 5 x 2.5 x 1.25 in., shockproof housing, VT100 measures air velocity from 0-6,000 fpm and temperature from -4 to +176°F. Along with 0.01 resolution, features include adjustable shutoff, m/sec or fpm unit selection, as well as Max, Min, and Hold functions. Ice Blue 128 x 128 pixel display can be read in light or dark environments. Handheld unit, suited for laboratories, clean rooms, air balancing, and more, comes with one 9 V battery and optional cones for air flow.

Anaerobic Chamber offers precise O2 and CO2 control,.

Anaerobic Chamber offers precise O2 and CO2 control,.

Sheldon Mfg. Inc.    Cornelius, OR 97113 8507
May 15, 2012 Offering precise O2 and CO2 control from 1%-20%, SHEL LAB Bactrox Chamber preserves optimal application conditions during incubation as well as in chamber work station. Removal of cultures from incubator does not require exposure of cells to undesirable O2 or CO2 levels, while standalone 300 plate incubator, included, lets users work without gloves in ambient room conditions. Atmospheric controller allows use of zirconium dioxide O2 sensor, with independent O2 and CO2 control and logging.

X-Ray Inspection System meets packaged food manufacturing needs.

Eagle Product Inspection    Tampa, FL 33634
May 11, 2012 Capable of withstanding impact of repeated use of harsh chemical cleaners and pressurized water, Eagle Pack 400 HC increases uptime and hygiene in wash-down environments. Stainless steel plates, cut and welded together, eliminate food debris collection points, while interlocked hinged louvers facilitate access to conveyor. While water-cooled heat exchanger eliminates need for separate A/C unit, knurled end drive roller with v-grooves ensures conveyor belt traction and position retention.

Opto-Digital Imaging Systems offer touchscreen operation.

Opto-Digital Imaging Systems offer touchscreen operation.

Olympus America, Inc.    Center Valley, PA 18034
May 10, 2012 Intended for inspection, test, and quality control facilities, DSX Series Micro-Imaging and Metrology Systems capture clear images, acquire traceable measurements, and perform high-level analyses with tap of touchscreen. Units accommodate samples of all shapes and sizes to produce 2D, 3D, and panorama results. Built to resist ambient vibration with image stabilization technology, DSX systems are compatible with Stream image-processing software for measurement, analysis, and reporting.




(Showing headlines 121 - 140)   1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68


Home  |  My ThomasNet News®  |  Industry Market Trends®  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2013 Thomas Publishing Company. All Rights Reserved.
Terms of Use - Privacy Policy