 Garment Racks suit cleanroom storage applications.Eagle MHC
Clayton, DE 19938
Jan 19, 2006
Available in stationary and mobile models, chrome finished garment racks feature QuadTruss® structural wire design and construction allows vertical air flow. Racks provide top shelf storage of hats and flat items, bottom shelf for shoes, and optional solid shelf that can be positioned underneath to catch water or moisture. Racks are offered in 48, 60, and 72 in., with hanger slots, hooks, or hanger tubes.
|
 Soft-Wall Cleanroom Material grounds out electrical charges.Wilson Industries, Inc.
Pomona, CA 91768-3278
Jan 16, 2006
Featuring carbon scrim, Electro-Safe heavy-duty transparent vinyl curtain is designed to bring voltage down to zero. Fire-resistant, 12 mil curtain is suited for oxygen-rich and dust-free atmospheres. Resistant to abrasion, cleaning processes, and corrosion, anti-static curtain is also useful for areas in which danger from explosives is present. Applications include machine and instrument covers, soft-wall cleanrooms, and electronic industry safety screens.
|
Gas Chromatograph obtains near real-time measurements.Varian, Inc.
Palo Alto, CA 94304
Jan 10, 2006
Suited for industrial process monitoring systems, CP-4900 PRO Micro-GC quantifies potentially detrimental contaminants in natural gas, ambient air, and other environments. It provides built-in data handling capability and is fully compatible with standard communication protocols including MODBUS, RS-485, RS-232, or Ethernet without need for local PC or data handling software. Chromatograph operates continuously and measures sample stream components from % to ppb.
|
Cell Culture System is completely disposable.New Brunswick Scientific Co., Inc.
Edison, NJ 08818
Jan 04, 2006
Eliminating need for cleaning and autoclaving, FibraStage(TM) disposable cell culture system produces high yields of protein, virus, or cell mass from anchorage-dependent or suspension cultures. Console base accommodates up to four 500 ml disposable culture vessels pre-filled with FibraCel® disks. In addition to virus and vaccine production, applications include gene therapy/drug discovery, human proteome and cell therapy, and tissue engineering.
|
Endotoxin-Free Kits accelerate gene therapy studies.Sigma Aldrich Corp.
St. Louis, MO 63103
Dec 28, 2005
GenElute HP Endotoxin-Free Giga Select Kits provide isolation of endotoxin-free plasmid DNA from recombinant E. coli cultures. Up to 14 mg of high copy plasmid with less than 0.1 endotoxin units/ug can be recovered in less than 2 hours. With nearly undetectable levels of endotoxin, Giga Select kits give customers doing gene therapy studies and transfection of endotoxin sensitive cell lines tools for accelerating research.
|
 Plastic Ampoule features large surface area applicator tip.James Alexander Corp.
Blairstown, NJ 07825
Dec 27, 2005
Offered in 2 and 5 ml sizes, Plastic Ampoule allows users to activate package with gentle squeeze of one hand, rupturing internal membrane. Another gentle squeeze dispenses contents onto applicator tip. Made from molded plastic, large surface area tip is offered with different types of foam applicators, depending upon composition of user's formula and nature of application. Large tip version is suited for cosmetic, personal care, and pharmaceutical applications.
|
Fly-Height Tester is suited for HDD manufacturers.KLA-Tencor Corp.
San Jose, CA 95134
Dec 27, 2005
Designed for data storage industry, D6 fly-height metrology system uses laser-based phase interferometer to test down to contact with precision within 0.15 nm and matching within 0.64 nm. Multiple signals are used to directly discern differential phase of light reflected off recording head surface without need for calibrating intensity envelope of interference fringes. Measurement principle enables repeatable measurements down to sub-3 nm fly-heights.
|
Barrier Isolater handles hazardous pharmaceutical compounds.Baker Company., The
Sanford, ME 04073
Dec 26, 2005
Available as 5 ft wide, 2-glove position unit, ChemoSHIELD® Model CS500 offers contained, negative-pressure work area suitable for potentially harmful chemotherapy agents or IV admixtures. Its unidirectional HEPA-filtered airflow of better than ISO Class 5 air cleanliness conditions within chamber prevents migration of hazardous contaminants. Ergonomic design has slanted viewscreen angled at 10° with top hinge to allow full opening for loading of pharmacy equipment.
|
Integrated Cytometry System standardizes testing procedures.Beckman Coulter, Inc.
Fullerton, CA 92834-3100
Dec 15, 2005
Offering laboratory information system (LIS) connectivity, Integrated Cytometry Solution combines FC 500 flow cytometer with FP 1000 sample processing system to streamline workflow and provide complete patient sample tracking. Solution, suited for high-volume clinical reference laboratories, tracks samples throughout testing process, from receipt and preparation to acquisition and analysis of data to reporting of results.
|
 Upright Compound Microscopes target research environment.Jenco International, Inc.
Portland, OR 97222
Dec 12, 2005
Offered in binocular and trinocular models, BC Series is available with bright field plan, phase plan, phase achromatic, and infinity optics. Units are equipped with 209 x 140 mm mechanical stage, all metal gear train mechanism, two 10x wide field eyepieces, and 4 standard objectives, including 4x, 10x, 40x R, and 100x R. Kohler Illumination features field diaphragm and 20 W, 6 V halogen bulb with electronic dimmer.
|
 Moisture Standards Generators suit general laboratory use.Kin-Tek Laboratories
LaMarque, TX 77568 4202
Nov 30, 2005
Offered in single- and dual-range models, Span Pac(TM) H2O Moisture Standards Generators provide source of trace concentrations of moisture in gas. Systems use Trace Source(TM) permeation tubes to add known amount of water vapor to flow of dried gas in concentrations from less than 10 ppb to 1%. At any concentration level, multi-point calibrations are achieved by adjusting flow of dry dilution gas. Concentration can be varied over 20:1 range with single permeation tube.
|
Development Platform targets software-defined radio projects.Pentek Inc.
Upper Saddle River, NJ 07458
Nov 23, 2005
Pentek SCA 2510 hardware platform consists of Pentek 7640 software radio transceiver PCI card installed in Linux workstation, development tools, and SCARI++ SCA core framework. Hardware and software are fully integrated, and PCI card is pre-configured with drivers and libraries for development of Joint Tactical Radio System (JTRS) application development for communication among military forces, civilian emergency centers, and law enforcement agencies.
|
 Dissolution Tester complies with pharmacopeia methods.JASCO, Inc.
Easton, MD 21601
Nov 15, 2005
Fully automated DT-810 tests dissolution of up to 8 samples with paddle or rotating basket method. Circular design provides uniform water temperature and utilizes round heating element, while Direct-Center(TM) automatic centering mechanism provides hands-free positioning of dissolution vessels and drive shafts. All components can be controlled via PC using graphic interface. Tester can be incorporated with flow, fraction, and fraction flow systems.
|
 Process Gas Chromatograph has field-mountable design.Emerson Process Management / Rosemount Div.
Chanhassen, MN 55317
Nov 15, 2005
To permit measurement of trace hydrocarbons at parts-per-billion concentrations, explosion-proof Rosemount Analytical Model 700 employs micro-flame ionization detector (µFID) with detector pre-amplifier/electrometer board. Micropacked methanator permits measurement of trace CO and CO2 in ethylene, propylene, and other polymer-grade chemicals. Other features include Flame Photometric Detector module, heated liquid sample injection valve, and heated sample transfer tubing.
|
 Gas Dryers handle flows up to 1 lpm.Perma Pure Inc.
Toms River, NJ 08754
Nov 08, 2005
Designed to dry hot, wet, sample gases prior to analysis, MDH(TM) Series combines heating element with Nafion® technology, which selectively removes only water from sample gases, leaving rest of gas sample unaffected. Dryers remove water directly from vapor phase, preventing loss of water-soluble gases through dissolution in condensate. Units can dry gases with as much as 30% water by volume and use built-in thermostat to prevent condensation throughout drying process.
|
 Titration Workstation lets user program up to 10 methods.Radiometer Analytical SAS
69627 Villeurbanne CEDEX France
Nov 04, 2005
Suited for routine potentiometric titrations, TitraLab 840 offers measuring ranges of -9 to 23 pH, ±2,000 mV, and -10 to +100°C with resolution of 0.001 pH, 0.1 mV, and 0.1°C, respectively. It provides Methods End Point titration with 1-2 preset end points and Inflection Point titration with auto determination of 1-4 inflection points and programmable IP acceptation windows. Unit includes password protection for programming access, non-volatile memory, and storage of last 60 results.
|
Microscope features laser pulse mode.Imago Scientific Instruments Corporation
Madison, WI 53719
Nov 04, 2005
LEAP® 3000X expands capabilities of atom probe microscopy to low electrical conductivity samples by adding laser pulse mode to voltage pulse mode of LEAP 3000 Microscope. Voltage pulse mode applications include precipitate composition and distribution, phase/grain boundary analysis, nuclear materials, thin metal films, and interface engineering. Laser pulse mode can be used for ceramics, GMR/TMR devices, thick dielectric films, high-K dielectrics, and high resistivity silicon.
|
 Calibration Standards include Traceable® Certificate.Control Company
Friendswood, TX 77546
Nov 02, 2005
Traceable® A2LA Conductivity Calibration Standards provide accuracy of ±0.25 µΩ at 25°C for 5 and 10 solutions and ±0.25 for other solutions. Compatible with all makes of equipment, each bottle is labeled for calibrating conductivity, resistivity, and dissolved solids. Supplied complete, standards come with step-by-step calibration instructions, traceability information, individual temperature compensation chart, and Traceable® Certificate.
|
 Cryogenic Comparator provides over 10 in. of immersion.EDL, Inc.
Danville, VA 24540
Oct 31, 2005
Offering alternative to argon triple point and other cryogenic calibrators, Cryo-Cal® utilizes phase change point of liquid nitrogen to establish reference temperature of approximately -196°C or 77 K. Four Teflon® lined bushings guide sensors into gold-plated equalization block, which resists corrosion and oxidation and contributes to 0.002 K stability and uniformity. With no moving parts or pumps, Cryo-Cal is virtually maintenance-free.
|
 Joystick Drive/Controller comes with Motion Db software.Nymotion LLC
Portland, OR 97229
Oct 27, 2005
Offered with Windows XP microscopy application, NYT-JS addresses needs of cytology slide processing. Combined with Leica ergonomic microscope, it provides hardware and user interface for slide scanning and/or joy sticking across microscope slides to capture multiple cell coordinates while adding screener and reviewer notes. Data, map, and images are stored in MS ACCESS database and can be shared with email or snap review collaboration sessions using instant messaging format.
|