HVAC

HVAC

Packaged Blower can be used in air conditioners and ovens.

Mar 26, 2002

Centrifugal blower utilizes electric motor, and offers CFM ranges from 15 to 1200 free air. Design configurations can incorporate single or double inlets and outlets. Blower inlet options include bezels, safety screens, and die cast adaptors. Output features include round, square, and other mountings. Available shapes include round, square or flanged. Blower is suitable for use in flue exhausts,... Read More

HVAC, Sensors Monitors & Transducers, Test & Measuring Instruments

Flow Meter handles raw sewage, irrigation, and stormwater.

Mar 21, 2002

Area-Velocity Flow Meter (AVFM) monitors flow through open channels, partially full sewer pipes, and surcharged pipes without flume or weir. Submerged ultrasonic sensor continuously measures both Velocity and Level in channel. Fouling- and corrosion-resistant sensor is tolerant of turbulence. AVFM can be configured with submerged Velocity/Level sensor, or with submerged velocity and separate... Read More

Controls & Controllers, HVAC

Temperature Controller offers push-button operation.

Mar 21, 2002

Series 59 microprocessor-based, digital temperature controller has 3-digit LED display for viewing set point from distance. It supports RTD or thermistor inputs, which can be factory preset to 999°F, and provides solid-state driver or mechanical relay outputs. UL-recognized 59 Series utilizes board-level pin connectors and includes 2 to 6 buttons for up/down settings, °F/°C, and timers.... Read More

HVAC, Material Handling & Storage

Air Compressor is portable and gasoline-powered.

Mar 21, 2002

AC1-HH04-05M hand-carry air compressor utilizes 4.0 HP OHV engine, and has single-stage compressor, twin tank design, powder-coated 5 gal capacity tank, drain valves and pressure release valve, and protective pump and motor housing. Crankcase and head are made of aluminum, and cylinder is cast iron. Two handled system allows 1 or 2 man transporting. Read More

HVAC

Ionizing Air Blower eliminates static charges.

Mar 19, 2002

Steady-state DC Model 1552 Megastatic Ionizing Air Blower eliminates static in plastics component applications. Available as self-balancing static control blower, it is offered in sizes from 8 to 48 in. It can be used at workstations or over manufacturing machines for lowering dust contamination potential and reducing operator shocks. Ionizers are available with heaters and speed control, and do... Read More

Controls & Controllers, HVAC

Dehumidifier controls humidity independently of temperature.

Mar 19, 2002

HCU desiccant dehumidification system treats 100 percent makeup air and works with existing A/C system or energy recovery ventilator (ERV). It controls humidity on as-needed basis, when humidity or temperature levels exceed set point. System removes humidity using combination of DX cooling and desiccant rotor. Nominal flow rate is 1000 scfm, with moisture-removal rate of 37.3 lb/hr at 90 degrees... Read More

HVAC

Power Venters fit commercial appliances.

Mar 12, 2002

SWG Commercial Series uses standard industrial motors built to NEMA 56-C standards to vent oil and gas appliances up to 3 million Btu. Vents are available in 10, 12 and 14 in. sizes with single phase 115/230 Vac TEFC motors. Each has separate motor starter with thermal overload protection. Venters can be installed through walls up to 12.5 in. thick with as little as 1/2 in. clearance to... Read More

HVAC, Test & Measuring Instruments

Temperature Measurement System uses miniature IR sensor.

Mar 11, 2002

Series MIL Mini In-Line 2-piece system has non-contact sensing head and separate electronics. Electronics offer emissivity, peak hold, valley hold, and averaging function, which are adjustable on 5-digit LCD. Sensor is housed in stainless-steel enclosure for harsh environments. Series is designed for temperature ranges from -40 to 1112 deg F. System has accuracy of ±1% of reading or ±1 deg... Read More

HVAC

Dust Collector meets workplace air specs.

Mar 08, 2002

Gold Series(R) line of cartridge dust and fume collectors use Poly-Tech(TM) silicone-impregnated polyester/cellulose media. Collectors meet or exceed 5 mg/cu m emissions threshold on non-hazardous dusts required to recirculate air back into workplace. They are suitable for removal of all types of fine, dry dusts. Optional 99.99% efficient version removes 0.5 micron and larger particles for more... Read More

HVAC

Paddle Blade Fans operate quietly.

Mar 08, 2002

Multi-Wing 8M Series has broad paddle blades that achieve lower turbulence at tips, thus producing lower noise than traditional stamped metal fans. Blades are thermoplastic and hub is cast aluminum for strength, low weight and corrosion resistance. Fans are available in 3 standard angles and 10-20 in. dia. Standard and special inch or metric bores can be provided. Applications include cooling... Read More

HVAC

Compressor fills cylinders with oxygen and other gases.

Mar 05, 2002

Oil-free, compact RIX MicroBoost booster compressor fills gas cylinders with oxygen, nitrogen, air and other gases to 2,200 psig. 3-stage system allows user to draw supply cylinders down to 0 psig. Available in 110 and 230 V configurations, it weighs 40 lb, fits in 16 x 9 x 14 in. space, and produces 20 SCFH. Motor-driven booster does not rely on air or nitrogen for drive power, which can save... Read More

HVAC

Dust Collector suits low headroom installations.

Mar 05, 2002

Side Winder Model DKCD 72030 is a 30 HP, 7,500 CFM dust collector featuring side mounted fan and flat envelope-shaped filters. It is only 122 in. tall, and typically used for collection of wood dust from maintenance shops and removal of powders caused by mixing or blending. Dust is collected in four 55-gal drums. Unit can be installed outdoors or indoors if local fire codes permit. Read More

HVAC, Machinery & Machining Tools

Semi-Synthetic Coolant offers lubricity and rust protection.

Mar 05, 2002

Rustlick® Ultracut 370R can be used for both machining and grinding. Heavy-duty coolant is formulated for wide range of ferrous and non-ferrous metals. It provides long sump life due to biostability and rust protection. Coolant is available in 5 and 55 gal containers. Read More

HVAC, Laboratory and Research Supplies and Equipment, Plant Furnishings & Accessories

Workstations incorporate HEPA filters.

Mar 01, 2002

Laminar Flow (Unidirectional) Workstations are available in horizontal, vertical, crossflow, and peripheral flow configurations. Their HEPA (High Efficiency Particulate Air) filters are rated 99.99% efficient on 0.3 microns or larger as defined by Federal Standard 209. Available models include 4003 Series Table Top Work Station and 4070 Fume Hoods. Models are suited for cleanroom, aerospace,... Read More

HVAC, Machinery & Machining Tools, Paints & Coatings

Color Change Powder System operates at 1000 CFM.

Feb 27, 2002

QualityCoat(TM) ColorChange booth includes removable cartridge module for color change. Variable speed motor drive controls booth containment air. It has built-in self-diagnostics, and provides motor status readout, voltage surge protection, and phase loss detection circuits. Fan speed can be preset or infinitely variable. Unit is equipped with electrical control panel and booth pneumatic control... Read More

HVAC

Dust Collector allows continuous production.

Feb 27, 2002

Whirl/Wet Dust Collection System has radiused welds so that material cannot accumulate in unit. Its 100% polypropylene construction makes it highly resistant to mechanical damage. System is available in capacities from 500 to 50,000 cfm, and suitable for applications that generate dusts larger than 2 microns. It is self-cleaning and functions without pumps or internal moving parts. PLC monitors... Read More

HVAC

Water Chillers have capacities to 58 tons.

Feb 19, 2002

Compact ultracool process water chillers are suited for process cooling applications that require precise temperature control and reliable operation. Chillers have cooling capacity range of 0.23 to 58 tons with options available to customize units to specific applications. Read More

HVAC, Machinery & Machining Tools

Cooling System suits dry grinding applications.

Feb 13, 2002

Kool-Grind System includes chiller with 4x4 in. plate and 6x12 in. electromagnetic chuck. Chiller runs coolant through plate and chuck to cool work-piece during grinding, prevent heat build-up and warping, reduce grinding wheel breakdown, and allow closer tolerances. It avoids use of flood coolants or mist sprays. Applications include thin parts, mold inserts and die sections. Read More

HVAC

Steam Boilers prevent leaky tubes.

Feb 12, 2002

EX Series gas/oil steam boilers have rows of vertical water tubes sandwiched between 2 ring-shaped headers. Because headers are only attached to tubes, they float, unconstrained, up and down with tubes' thermal expansion and contraction. Boilers reach full steam in 5 min and maintain 85% fuel to steam efficiency. Read More

HVAC

Flexible Water Boilers come in sizes from 6 through 25 BHP.

Feb 07, 2002

DR Series steam and hot water boilers are available in forced draft gas, oil, or dual fuel (gas/oil) fired models. They utilize tube configuration, which provides water-cooled combustion chamber, and stimulates heat transfer. Removable/replaceable tubes require 24 in. for maintenance access. Largest size DR Series boiler is 33-7/8 in. wide, and will fit through most doors. Read More