ThomasNet News Logo
Sign Up | Log In | ThomasNet Home | Promote Your Business
 Journals
Industry Market Trends ®
Fluid & Gas Flow Journal
Machining Journal
Procurement Journal
Tech Trends Journal
 Industry News
Latest New Product News
Association & Government News
Thought Leaders
 Product News
Adhesives and Sealants
Agricultural and Farming Products
Architectural and Civil Engineering Products
Automatic ID
Chemical Processing and Waste Management
Cleaning Products and Equipment
Communication Systems and Equipment
Computer Hardware and Peripherals
Construction Equipment and Supplies
Controls and Controllers
Display and Presentation Equipment
Electrical Equipment and Systems
Electronic Components and Devices
Explosives, Armaments and Weaponry
Fasteners and Hardware
Fluid and Gas Flow Equipment
Food Processing and Preparation
Green & Clean
Health, Medical and Dental Supplies and Equipment
HVAC
Labels, Tags, Signage and Equipment
Laboratory and Research Supplies and Equipment
Lubricants
Machinery and Machining Tools
Material Handling and Storage
Materials and Material Processing
Mechanical Components and Assemblies
Mechanical Power Transmission
Mining, Oil Drilling & Refining
Mounting and Attaching Products
Non-Industrial Products
Optics and Photonics
Packaging Products & Equipment
Paints and Coatings
Plant Furnishings and Accessories
Portable Tools
Printing and Duplicating Equipment
Retail and Sales Equipment
Robotics
Safety and Security Equipment
Sensors, Monitors and Transducers
Services
Software
Test and Measuring Instruments
Textile Industry Products
Thermal and Heating Equipment
Timers and Clocks
Transportation Industry Products
Vision Systems
Waste Handling Equipment
Welding Equipment and Supplies
 Press Releases
Products in the News
Company News
Mergers & Acquisitions
People in the News
Literature & Websites
 Resources
News Delivery Options
Newsletter Archive
SME
Browse Categories
Browse Companies
Mobile Edition
PR Resources
Licensing
Advertising
Call for Contributors, Guest Writers and Submissions
How to Write an effective Press Release
Trade Associations
Fluid & Gas Flow Equipment -> Filters & Breathers -> Gas Filters


Gas Filters




(Showing headlines 1 - 20)   more ....
Fresh Air Filter Pre-Filter helps maintain fuel economy.

Fresh Air Filter Pre-Filter helps maintain fuel economy.

FreedomAirFilters    Madison, NE 68748-0165
Sep 26, 2014 Constructed with 1/8 in. thick ABS plastic and polyester mesh with uniform micron openings, Peterbilt fresh air filter pre-filter protects fresh air filter for Peterbilt models 379, 378, 377, 386, 389, and 388. Product specifically keeps particles of debris, such as rubber, dirt, sand, and grain chaff, from getting into and clogging pleats of air filter element. Pre-filter is treated with hydrophobic water repellant process and catches particles as small as .005 in.

Ductless Filtration System protects against chemical vapors.

Air Science USA    Fort Myers, FL 33906
Aug 27, 2014 Designed to protect laboratory personnel from chemical vapors found inside stand alone chemical safety cabinets, Vent-Box utilizes Multiplex Filtration System, which combines pre-filter and main filter to create chemical, physical, or combination architecture that adsorbs, neutralizes, or traps target chemicals or particulate. Constant negative pressure removes vapors and particulates from cabinets interior. Fumes are pulled via flexible hose and clean, filtered air is returned to laboratory.

Pre-Filters target agricultural and trucking industries.

FreedomAirFilters    Madison, NE 68748-0165
Aug 21, 2014 Constructed of proprietary polyester mesh with uniform micron openings and treated with hydrophobic water repellant process, Pre-Filters prevent larger particles of debris such as rubber, dirt, and sand from getting into and clogging pleats of air filter elements. Units catch particles as small as .005 in., extending filter life. Designed to fit over existing under-the-hood filter as well as cabin filter, pre-filters can be used over and over as they are cleaned with soap and water.

Truck Air Cleaner has low-profile design.

Vortox Air Technology, Inc.    Claremont, CA 91711
Aug 05, 2014 Available in 13 in. (27.75 in. tall) and 15 in. (31.88 in. tall) models, Low-Profile Truck Air Cleaner features shortened screen and stud design that eliminates need for truckers to cut screens and studs themselves in order to customize their rigs. Products are compatible with Kenworth W-900 and Peterbilt 359/379/389 trucks. Cleaners use Vortox filter elements, which offer optimized performance via all-T304 stainless steel construction, dirt holding capacity, and integrated inlet cap.

Filter, Regulator, and Lubricator feature modular designs.

Filter, Regulator, and Lubricator feature modular designs.

Ross Controls    Troy, MI 48083
Jul 18, 2014 Offered in ¼, 3/8, and ½ port sizes with NPTF port threads, MD3™ Series features locating tabs on bowls for tightening accuracy. General purpose filters offer 5 or 40 micron filtering elements and free water removal, while coalescing filters feature 0.3 or 0.01 micron elements with 99.98% free oil particulate removal and 0.3 micron solid contaminant removal. Other products include: oil vapor removal filters, general purpose regulators, modular lubricators, and integrated filter/regulators.

Fume Extractor features mobile design for occasional use.

Fume Extractor features mobile design for occasional use.

KEMPER GmbH    Vreden   Germany
Mar 31, 2014 Specifically designed for low amounts of dust, Smart Master features rotatable and swiveling exhaust hood that enables use in 360° radius. W3 approval make welding fume filter system suitable for welding chrome, nickel, and steel. Instead of exhaust arm, SmartMaster can also be connected by hose below welding table, so that suction of smoke particles is carried out directly at source. Three-stage disposable filter ensures clean air when welding with maximum suction capacity of 950 m³/h.

Ceiling-Mount Air Filtration Units protect personel, environment.

Ceiling-Mount Air Filtration Units protect personel, environment.

Air Science USA    Fort Myers, FL 33906
Mar 18, 2014 When used in areas where hazardous substances are handled, Purair SKY ceiling mounted filtration units help protect laboratory personnel and environment via integrated Air Science Multiplex Filtration system and Air Science EFT (Enhanced Filtration Technology). Dynamic filtration chamber features sliding filter clamp which facilitates and accelerates filter changes. As standard, units come with epoxy-coated steel support frame with LED lighting and wall-mounted controls.

PC Enclosure turns computers into air purifiers.

Seal Shield, LLC    Jacksonville, FL 32205
Mar 04, 2014 Developed for healthcare market, AeroShield™ Computer Enclosure is designed for infection prevention. Product utilizes Airocide™ technology, developed by NASA, to destroy organic pathogens while cooling and filtering air, protecting patients and practitioners. Enclosure also helps keep computer electronics free from particulate debris, extending equipment life.

High Temperature Filter Elements suit biomass gasification.

High Temperature Filter Elements suit biomass gasification.

Porvair Filtration Group    Ashland, VA 23005
Jan 29, 2014 High temperature filters feature metallic filter elements. Metallic filter material permits higher temperature duties to be considered as required for biomass gasification, and Pulsejet design enables biomass gasification filter cakes to be removed effectively to ensure continuous on-service performance.

Multilayer Composite Filters increase cleaning efficiency.

Multilayer Composite Filters increase cleaning efficiency.

Porvair Filtration Group    Ashland, VA 23005
Dec 12, 2013 As self-supporting cylinders, 4- and 5-layer composite mesh filters enable filtration down to sub-micron levels in both gas and liquid applications when incorporated into dedicated filtration systems. Suitable uses include such applications as critical chemical filtration duties and backwash refinery slurry oil filters. Designed for in-situ cleaning, filters are optimized for cleaning efficacy combined with permeability to maintain favorable throughput of filtered media.

Air Regulation and Filtration Panels utilize nanotechnology.

3M    St. Paul, MN 55144
Oct 16, 2013 To enhance air quality for workers using supplied air respirator systems, Versaflo AP-600 Series helps control pressure of air delivered and remove contaminants and nuisance odors from compressed air. Design facilitates filter removal/changeout, weighs <25 lb, and can be carried or mounted to wall. Configured to allow for 5–12 users, panel has 100 cfm air flow capacity and supports optional cartridge that helps filter carbon monoxide (CO). CO/oxygen monitor with alarms is optional.

Ultra High Purity Gas Filters target semiconductor facilities.

Mott Corporation    Farmington, CT 06032 3159
Jul 02, 2013 With max operating pressure of 2,500 psig and max operating temperature of 842°F, GasShield® Defender DEF2000 provides 9 log reduction of particles (99.9999999%) down to 3 nm at flow rates over 2,000 slpm. Series is suitable for high flow bulk specialty and inert gas delivery systems. GasShield® Defender DEF4000, providing 9 log reduction of particles down to 3 nm at flow rates over 4,000 slpm, allows engineers to minimize footprint of bulk gas filter skids and gas panels.

Universal Cartridge Filters feature redesigned filter body.

Universal Cartridge Filters feature redesigned filter body.

Atrix International, Inc.    Burnsville, MN 55337
Jun 17, 2013 In addition to tongue and groove design that strengthens filter while minimizing or eliminating potential for leaks, Omega 31700 series, OF612 series, and OF712 series incorporate bodies with 4 radii corners which improve strength and appearance. Width of band area promotes connectivity. These cartridge filters are available for all Omega Plus, Omega Supreme Plus, 3M 497 Series Field Service Vacuums, Katun UltiVac, and UltiVac Deluxe Series Vacuums.

All-Metal Filters handle low vapor pressure gases.

Mott Corporation    Farmington, CT 06032 3159
Jun 05, 2013 Featuring all-metal 316LSS construction that can be heated to 450°C, FLP Series is suited for filtering low pressure, vapor phase dopants used in metal-organic vapor phase epitaxyor, advanced chemical vapor deposition, and atomic layer deposition applications. Open filter media enables passage of low pressure liquid source gas while having enough surface area to remove particles down to 0.003 µm, and is effective at preventing large particle agglomerations from migrating downstream.

Air Cleaner handles commercial kitchen exhaust emissions.

Trion    Sanford, NC 27331
May 17, 2013 Designed to treat grease, smoke, and odor emissions from exhaust ducts on commercial cooking applications, Grease Viper™ can be configured with multiple stages of filtration for both particulate and odor control. System is typically furnished as complete pollution control unit with automatic water-wash components for electrostatic precipitator filters, as well as odor control section, exhaust fan, system rails, pre-piped fire suppression nozzles, and necessary controls.

Contaminant Removal System serves blown film extrusion plants.

Contaminant Removal System serves blown film extrusion plants.

Future Design Inc.    Mississauga, ON L4W1G6  Canada
Apr 02, 2013 Saturn Evacuation System (SES) helps blown film extrusion plants reduce airborne contaminants by up to 80% and extends cleanings from every 6 weeks to quarterly or longer. Connected to vacuum side of blower, SES comprises air ring that fits any air ring or die constructed of aluminum. System creates positive vacuum that draws contamination from low-pressure zone at die exit. Polluted air is then filtered, and discharged particulates are directed to suitable location.

Membrane Element improves contaminant removal from natural gas.

Honeywell International Inc.    Morristown, NJ 07960
Mar 18, 2013 As replacement option for elements within UOP Separex systems, UOP Separex™ Select removes contaminants, such as acid gas and water, from natural gas while minimizing amount of methane and natural gas liquids (NGLs) lost during contaminant removal process. Product can upgrade natural gas streams by removing CO2, H2S, and water vapor in single process to meet quality standards specified by pipeline transmission companies and end-users of natural gas.

Membrane Element improves natural gas processing capacity.

Honeywell    Golden Valley, MN 55422 3935
Mar 07, 2013 Providing natural gas producers with drop-in replacement for membrane elements in existing Separex membrane systems, UOP Separex™ Flux+ increases removal of contaminants, such as acid gas and water, that must be removed before natural gas can be transported by pipeline for commercial use. Membrane element, installed on-shore or off-shore, also optimizes removal of carbon dioxide CO2 membrane area, helping alleviate bottlenecks in downstream processing units.

Portable Oil Mist System features cyclonic technology.

Portable Oil Mist System features cyclonic technology.

Royal Products, Div. Curran Mfg. Corp.    Hauppauge, NY 11788
Feb 22, 2013 Measuring 18 x 20 in., Filtermist Ultra™ is top-mounted on mobile cart with locking casters and is designed to fit behind chip conveyor on most machines to remove oil mist and smoke. Internal cyclone optimizes particle separation, so clean air can be exhausted back to factory floor. Because system self-drains to machine tool coolant sump, it can operate continuously. Filtermist Ultra is suitable for machines with internal volume greater than 60 ft³ and exceeds OSHA/NIOSH safety regulations.

Air Cleaner delivers optimal air filtration without ozone.

LG Electronics USA, Inc.    Englewood Cliffs, NJ 07632
Jan 24, 2013 With near-HEPA filter performance, Dynamic V8® VL Series offers indoor air quality solution for Variable Refrigerant Flow systems without emitting ion or ozone pollutants. MERV 15+ rated unit reduces wide range of particulate and gas-phase contaminants, including ultra-fine particulate, VOCs, odors, and biological contaminants. Equipped with maintenance-free solid-state electronics, system only requires filter changes every 4 years and enables filter access without removing ceiling tiles.




(Showing headlines 1 - 20)   more ....


Home  |  My ThomasNet News®  |  Industry Market Trends®  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2014 Thomas Publishing Company. All Rights Reserved.
Terms of Use - Privacy Policy