 Screened Orifice suits medical applications.Lee Company, The
Westbrook, CT 06498 0424
Apr 14, 2003 IMH Screened Orifice is a miniature restrictor preinstalled in male to female luer adaptor with integral safety screen to protect orifice from contamination. Orifice and screen are 300 Series stainless steel and adaptor is medical grade polypropylene. Suited for liquid and gas applications, orifice comes in 18 standard flow rates and is 100% flow tested on water or nitrogen to ensure that each part is within ±5% of nominal flow rate. |
Membrane Vents protect sensitive equipment.Gore, W. L., & Associates, Inc., Sealant Technologies Group
Elkton, MD 22222
Mar 12, 2003 GOREâ„¢ Membrane Vents, offered in standard metric M12 thread size, allow passage of gases in and out of enclosed structures, while providing protection against water and particle inflow. Expanded polytetrafluoroethylene offers combination of fluid resistance and breathability. Membrane material consists of highly porous structure of fibrils and nodes, which is resistant to water, oils, chemicals, and UV, and stable through wide temperature range. |
Automatic Weirs promote flush cleanout.Witte Co., Inc., The
Washington, NJ 07882
Feb 20, 2003 Autoweirs feature pneumatically operated radius gates that automatically rotate 60° upwards and above decks of fluid bed dryers and coolers on cycle timer to permit real-time adjustment of bed depth and retention time. They enable operators to accelerate or slow rate of product advance during operation to achieve desired specifications for moisture content, shape, purity, crystalinity, and other parameters. Autoweirs permit changes in bed depth from ½ to 3 in.
|
 Air Preparation Components handle up to 300 scfm.ARO - Ingersoll-Rand Fluid Products
Bryan, OH 43506
Jan 30, 2003 Module/Air® 3000 units are offered in piggyback filter/regulator model and piggyback filter/regulator/lubricator configuration. Both include site gage, polycarbonate bowls with metal guards, and mounting hardware. Automatic drain has pipe connection for draining away contaminates. Push-pull, non-rising adjustment knob avoids unwanted or accidental adjustment. Components protect against mechanical failure caused by oil, water, and particle contaminants in air line. |
 Mixing/Flushing System cleans retention basins.ITT Flygt Corp.
Trumbull, CT 06611
Dec 06, 2002 Hydroejector acts as mixer when basin water levels are high and automatically becomes flushing device when water levels are low. Unit ensures that all solid materials are resuspended and flushed as basin is emptied, eliminating need for manual cleanup. To avoid clogging problems, pump is equipped with self-cleaning N-impeller. Ejector pipe removes organic matter from basin and features large diameter nozzle to further ensure clog-free operation. |
 Touchless Faucet offers ADA compliance.Sloan Valve Co.
Franklin Park, IL 60131
Oct 17, 2002 Optima Plus® EBF-85 sensor-operated faucet features microprocessor-based circuitry that automatically adjusts sensing range to type, depth, and reflectiveness of sink on which it is installed. By emitting continuous beam of infrared light, faucet's sensor activates water flow cycle when user's hands enter active area. Valve mechanism with self-cleaning bypass activates with every cycle. Clean-out strainer traps debris before it enters solenoid. |
 Engine Silencers keep diesel and gas engines quiet.Universal Silencer, A Fleetguard/Nelson Co.
Stoughton, WI 53589 0411
Sep 11, 2002 Product line includes four grades of engine silencers: Industrial grade for minimal silencing with noise reduction of 20 dB; Residential grade for moderate silencing with noise reduction of 25 dB; and Critical and Hospital grades for maximum exhaust silencing from 25 to +40 dB, respectively. Line also includes specialty units such as spark arresting silencers; low-pressure drop units; space saving units, which are 50% smaller than conventional units; and insulation blankets.
|
 Solid Surface Sinks come with electronic faucets.Sloan Valve Co.
Franklin Park, IL 60131
Aug 05, 2002 Solid-surface SloanStone sinks can be combined with any Optima® Electronic Faucet to provide practical and aesthetically pleasing lavatories. Sinks withstand heat, stains, and chemical damage; are available in range of colors; and are easy to maintain. Sensor-operated faucets available include models EAF 100 and 150; ETF 610, 600, and 80; and EBF 615, 650, 187, and 85. Applications include airports, office buildings, stadiums, and executive suites.
|
 Pipe Elbow conditions flow, cut caviation.Fluid Components Intl.
San Marcos, CA 92069 5115
Jul 18, 2002 Elbow Process Conditioner makes 90° turn to isolate flow disturbances, reduce swirl, and develop highly symmetrical, repeatable flow profile with minimal pressure loss at inlet to process equipment. It replaces last pipe elbow upstream of pump or valve. Elbow has anti-swirl and inclined vortex generating profile correction tabs. They project from inside pipe surface to generate vortices that accelerate and amplify natural pipe effects. |
 Flow Divider Cartridge diverts excess flow.Source Fluid Power, Inc.
Chaska, MN 55318
Jul 08, 2002 FPC 16 three-port pressure compensated priority divider cartridge provides pressure compensated flow to priority port. It bypasses excess flow to tank or other work functions. Bypass or excess flow port can be plugged. In applications where bypass flow is used for additional work, priority flow is unaffected by pressure changes in bypass circuit. Valve operating pressure is 3,000 psi max. Priority flow range is from 1 to 30 gpm. Total input flow can be up to 40 gpm. |
 Compressor Analyzer monitors, manages, and controls via Net.Atlas Copco Compressors Inc.
Holyoke, MA 01040 2768
May 28, 2002 ES Millennium has central controller and monitoring system that can control compressors and provide remote 24 hr monitoring via Local Area Network, Internet, or both. Each compressor's operational data can be sent via Internet to secure central warehouse, where specialists analyze data, plan for maintenance to avoid damage or production loss before it happens, suggest improvements to overall compressor setup, and propose energy optimizations.
|
 Flow Switch protects against flow variation.FloCat
Kenosha, WI 53144
May 22, 2002 Vane operated C-WD15-S0 is magnetically actuated and supplied with field adjustable multi-layer vanes for installation in pipes from 1 1/2 to 20 in. Unit fits directly into pipeline tee, thredolet, or flange and meets NEMA-4 watertight construction. It is explosion proof and withstands pressures to 2,000 psig. There are no bellows, springs, or seals to fail. C-WD15-S0 is suitable for fluids and gases. |
 Flow Divider controls palletizer flow.Columbia Machine Inc.
Vancouver, WA 98661
May 03, 2002 Modular flow divider can be mounted onto any of company's floor-level palletizers to divide case rows or to act as centering device. By forming cases into 2 rows in row pusher, divider can increase overall processing speed of palletizer. When reversed, flow divider acts as centering conveyor to align cases to turning section, which provides greater control when handling multiple lines. |
 Flow Switch features in-line design.Gems Sensors Inc.
Plainville, CT 06062
May 03, 2002 FS-380P is constructed with polypropylene housing, PPS composite pistons, 316 wetted parts, and fluorocarbon O-rings. Operating pressure is 200 psi @ 70 deg F and 100 psi @ 212 deg F. Fixed set points range from 0.25 to 2.0 gpm. Switch is offered with 3/8 in. MNPT or quick disconnect ports and selection of mating connections including NPT, BSP, barb, and tube connections. Switch action is SPST 10 VA, terminated with 24 in., 22 AWG wire leads. |
 Flowmeters and Test Kits monitor liquid flows.Hedland Div. Of Racine Federated Inc.
Racine, WI 53404
Mar 22, 2002 EZ-View direct-reading flowmeters can be installed in any position from vertical to horizontal, without flow straighteners or special plumbing requirements. Flowmeters are available in 1/2, 3/4 and 1 in. NPT, or 3/4 and 1 in. sweat fittings. Meters offer flow ranges from 0.5 to 28 gpm depending on model. Also available is Flow-Alert Signal, which automatically triggers alarm control circuit if flow exceeds or drops below preset limits.
|
 Switchover System operates in -40 to 140 deg F temperatures.CONCOA
Virginia Beach, VA 23454
Mar 14, 2002 639 Series Switchover System is suitable for laser assist gas systems utilizing helium, nitrogen, oxygen, and argon for connection to tube trailers, cylinder cradles, or gas packs. Automatic switchover reserves assist gas supply when primary source is depleted, without pressure fluctuations. 639 Series is equipped with flexible pigtails or manifold connectors. Inlet pressure ranges from 3000 to 4500 PSIG, and delivery pressure ranges from 0-400 PSI. |
 Sanitary Faucets eliminate messes.Tomlinson Industries
Cleveland, OH 44125
Feb 19, 2002 Bag-In-Box faucets can dispense non-pulpy liquids with fingertip operation. Positive shutoff prevents leaks and drips. Bag-In-Box faucets are reusable and sanitary, and work with Scholle, Liqui-Box, Parish, and Rapak spouts. Bag-In-Box Decapper Tool opens 38mm caps on bag-in-box packaging. Pinch Tube Faucet is used with sanitary disposable bag and tube where product does not come in contact with the valve. |
 Liquid Flow Switch has PP/Rytron® or PVDC construction.Flowline Inc.
Los Alamitos, CA 90720
Feb 14, 2002 Model FT10 Thermo-Floâ„¢ offers adjustable switch setpoints from 0.04 to 3 fps. LED indicates flow or no-flow status, and relay or FET output provides secure interface with remote devices. Two probe lengths, one for pipe sizes from 1/2 to 1 1/2 in., and one for 2 in. and up, are available. Thermal dispersion flow switch measures liquid temperature to determine changes in flow velocity, and is not damaged by abnormally high flow viscosities. |
 Plastic Silencer provides alternative to metal.Parker Hannifin Corp., Pneumatic Div.
Richland, MI 49083 0901
Jan 17, 2002 M5 ASN Plastic Silencer offers noise reduction with minimum effect on air efficiency (79 dBA at max flow of 15 SCFM at 100 psig). It fits directly into exhaust port of commercial valves. Open surface area of polyethylene element permits rapid air discharge without undesirable back pressure. Silencer has pressure rating of 0 to 150 psig, temperature rating of 14° to 140° F, and is available with NPT or BSPT threads. |
 Timer Controller works on pneumatic conveying systems.Dwyer Instruments, Inc.
Michigan City, IN 46361 0373
Jan 11, 2002 Series DCT500 provides continuous or on-demand cleaning for receivers and pulse jet systems. Available in 4, 6 or 10 channels, each unit features 2 potentiometers for selecting time-on and time-off settings. High limit and Low limit control inputs are provided for use with on demand systems. For added safety, control circuitry, including control inputs, are isolated from line voltage. |