Fluid & Gas Flow Equipment ->
Other
Other
(Showing headlines 41 - 60) 1 2 3 4 5 6
|
 Flow Signal Conditioner provides 4-20 mA or 1-5 Vdc output.Omega Engineering, Inc.
Stamford, CT 06907
May 03, 2006
Offered with NEMA 4 (IP66) enclosure and CE approval, Model FLSC-45B dc powered frequency-to-analog output signal conditioner accepts low level magnetic pickup signal or high level dc pulse from flow paddlewheel sensor or turbine meter without amplification and converts it into analog output. It features ±0.15% of full scale accuracy, ambient operating temperature of 20-70°C, and operates on 15-32 Vdc with .025% repeatability.
|
 Liquid Flow Switches feature fixed set-points.Orange Research, Inc.
Milford, CT 06460
Apr 19, 2006
Designed for inline-use, 30000 Series fixed set-point flow switches are available with factory-preset flow settings in 6 steps from 0.1-1.5 gpm. They use solid brass or stainless steel pistons and pressure bodies and stainless steel springs to ensure reliable use up to 1,000 psig in applications where shock and vibration are common. Mounted where space is limited, switches suit OEM applications requiring simple flow switch actuation.
|
 Flow Limiter allows setting of maximum flow rate.WA Technology
Florence, SC 29506
Apr 11, 2006
Welding Gas Flow Limiter allows maximum permissible gas flow levels to be set on flowmeters/regulators employed in cylinder shielding or pipeline gas supply. Once desired maximum flow rate is set, flow rate limiter clamps over flow control knob by tightening set screw thereby preventing increases from desired level. Welders can reduce flow from that predetermined level as application dictates. Locking system ensures that settings are maintained.
|
Adapter converts flushometers to electronic operation.Sloan Valve Co.
Franklin Park, IL 60131
Mar 23, 2006
SMOOTH(TM) (Side-Mount-Operator-Over-The-Handle) retrofit product converts manual flushometers to water-conserving, sensor-based operation. Installed without turning off water, product offers out-of-the-box functionality and works for left or right handle installation on exposed manual water closet and urinal flushometers. SMOOTH Model EBV-200-A uses adaptive sensing technology to flush automatically, and manual override button enables flushometer to work in event of power failure.
|
Faucet includes water filtration system.Moen Incorporated
North Olmsted, OH 44070
Feb 15, 2006
Featuring ChoiceFlo(TM) technology, Chateau® faucet provides filtered and non-filtered water options in one system. During installation, separate handle is mounted next to faucet deck plate. To switch from tap to filtered water, user turns filtration handle, and separate water line delivers filtered water through hidden spout on faucet neck with flow rate of 1 gpm. Under-the-sink carbon filter eliminates impurities including lead and chlorine, and lasts 6 months.
|
 Drainage System facilitates surface water removal.Advanced Drainage Systems, Inc.
Hilliard, OH 43026
Feb 14, 2006
Designed to manage surface water in yards, fairways, and sports fields, DrainTech(TM) basins, channel drains, grates, and valve/meter boxes also assist those with flooded basements or malfunctioning septic systems. Basins and channels are manufactured using rigid polyolefins, and universal adapters enable DrainTech structures to connect with common types of pipe used in landscaping and turf applications.
|
Faucets feature ADA-compliant fingertip control lever.Sloan Valve Company
Franklin Park, IL 60131
Feb 06, 2006
QuickTop(TM) QT-Series includes Model QT-1521 Manual Kitchen Faucet and Model QT-1320 Manual Lavatory Faucet. Kitchen faucets incorporate elevated, swiveling spout to accommodate large pots and pans, and lavatory faucets have elevated spout to facilitate hand washing. Units have chrome finish, are offered with or without pop-up drain or deck plate, and come ready for installation with wrenches, stainless steel hoses, and mounting hardware.
|
 Exhaust Silencers diffuse air and muffle noise.2Linc.com
Hudson, MA 01749
Jan 16, 2006
Used individually or stacked, 2L Stackable No-Clog Air Exhaust Silencers reduce noise created by air exhausted from pneumatic equipment without interfering with operations. Noise reduction levels of 12-27 db are possible, depending on model or combination of models. Made from anodized aluminum, products, available in male and male/female NPT sizes of 1/8, ¼, and 3/8 in., have straight-through design that does not cause back-pressure build-up.
|
 Underground System manages stormwater runoff.CONTECH Construction Products Inc.
West Chester, OH 45069
Jan 05, 2006
Engineered to stabilize stormwater runoff, Optimizer(TM) underground detention system contains flow control devices that use pressure head to begin immediately discharging at max allowable rate from multiple orifices. Corrugated metal pipe detention solution reduces required storage volume as well as excavation and backfill requirements. Multiple sizing tanks, set up independently, accommodate equally for all storms that need to be met by designer.
|
 Custom Hose Assemblies fit exact application requirements.NewAge Industries Inc.
Southampton, PA 18966
Dec 16, 2005
Hose Assemblies range from simplistic braided PVC hose with barb-style fitting and hose clamp to fabric-and-wire-reinforced silicone suction hose with sanitary fitting secured by crimp-applied collar. Ready-to-install products are available in plastic and rubber materials such as PVC, polyurethane, and silicone, as well as Viton® and stainless steel overbraided PTFE.
|
 Board provides air flow and temperature measurement.Advanced Thermal Solutions Inc.
Norwood, MA 02062
Nov 18, 2005
Compact ISD-232(TM) board directly and simultaneously assesses air flow from 0-50 m/sec and temperatures from -30 to +150°C in computer feedback control and measurement systems using independent, mobile sensors that can be placed anywhere in test domain. Measuring 3.34 x 1.44 x 0.55 inch, board may be used to control devices such as laboratory wind tunnels and HVAC regulators or to provide read-out data for display systems. LabVIEW(TM) software is available.
|
 Drum-top Dispenser helps control spills.Enpac Corp.
Eastlake, OH 44095
Aug 15, 2005 Designed for dispensing material from 55 gal steel tight-head drums outfitted with pump, Drip Sentinelâ„¢ Drum-Top Workstationâ„¢ helps save liquids by catching and redirecting them back into drum. Made of non-corrosive and chemically resistant polyethylene, product features molded-in raised rim to reduce splashes and spills, and raised ribs that provide clean, flat area to place containers to be filled. Stainless mesh strainer screens liquids returning to drum. |
 Inlet Diffusers correct gas flow imbalances.AMISTCO Separation Products Inc.
Alvin, TX 77511
Jul 26, 2005 Uniflo Inlet Diffusers evenly distribute gas flow over downstream separator and remove bulk liquids and solids from gas stream. By maximizing liquid distribution, channeling problems and re-entrainment of liquid droplets in mist eliminator are avoided. Use of diffusers also prevents gas from jetting into liquid level creating further entrainment problems. Available in range of alloys, diffusers can be designed for vertical or horizontal separators. |
 Brass Flow Switches offer push-fit installation.Gentech International Ltd
Girvan Ayrshire KA26 9PS United Kingdom
Jul 22, 2005 Pushed into 22 mm copper pipe, Models FS13 and FS14 do not require coupling and sealing components, compression fittings, or threaded connection. With sensor connected and mounted vertically in pipe, switches operate at liquid flow rate of 1 lpm and max pressure of 10 bar at 20°C. Units feature brass housing and noryl internal components, making them suited for domestic boiler heating systems, industrial circulating pumps, or liquid dispensing applications. |
 Manifold System includes flow meter with 1-20 gpm range.AW-Company
Franksville, WI 53126
Jun 21, 2005 To replace outdated mechanical flow meters in paint mix rooms, Flow Meter and Manifold System adapts to current paint recirculation and transfer systems. Unit, constructed of 316 stainless steel, features JVM-60CG flow meter, RT-Ex2 battery-powered digital display, and ¼ in. NPT adapter for pressure gage. Unit also comes with 3 full port ball valves with complete bypass system and tri-clamp connections with Teflon o-rings. |
 Siphon and Pressure Feed Cups work with HVLP spray guns.Binks ITW Industrial Finishing
Glendale Heights, IL 60139
May 20, 2005 Stainless steel 1-quart siphon feed cup and 3 pressure assist cups are designed to provide precise fluid pressure control with conventional spray guns. They incorporate air regulator, flare lip cup, and flattened bottom cup design. They also feature proprietary check valve and vent design as well as lid, yoke, and lever design. Interchangeable parts include stainless steel cups, lids, lid gaskets, fluid tube, and yokes. |
 Line Stopping System eliminates water shutdown.Severn Trent Services
Fort Washington, PA 19034-2707
Apr 13, 2005
Jr. Hydra-Stopper makes pressure taps and line stops on water and wastewater lines, ensuring fire protection and continued service. It temporarily blocks flow of water in pipes ranging in size from ¾-2 in. Rated to 100 psi, system is suited for cast iron, asbestos cement, steel pit cast, ductile iron, plastic, and copper pipe. It can also be used to add service connections, chemical injection points, lateral lines, and tank connections ranging from ¾-2½ in.
|
 Compressed Air Sensor monitors air consumption.ifm efector, Inc.
Exton, PA 19341
Apr 04, 2005
Used to continuously monitor compressed air systems, efector Metris divides plant into zones based on number of fittings and potential leakage points in any area. Sensor can be mounted in supply pipe to monitor one machine or in plant zone to monitor several machines, sensing compressed air levels when equipment is on or off. Micro DC, PNP sensor models SD6001 and SD8001 have respective measuring ranges of 0-44 and 0-132 scfm.
|
 Explosion Vents feature ATEX-approved detection.Elfab Limited
Tyne & Wear NE29 8SD United Kingdom
Jan 21, 2005 Explosion vents are supplied with Panel Flo-Tel burst-detection device based on magnetically-actuated detection system that provides open signal once panel has operated. Panels are made from corrosion-resistant 316 stainless steel in sizes from 0.9–25.8 ft². Offered in various shapes, products operate over pressure range of 0.7–7 psig and in temperatures from -40 to +400ºF. Non-fragmenting design is suited for use in backpressure and vacuum conditions. |
 Pipeline Inspection Tool uses medical sensors.GE Energy
Atlanta, GA 30339
Dec 14, 2004 UltraScan® Duo, suited for use in oil and gas industries, utilizes phased array ultrasound technology to perform pipeline inspections in one run. Automated sensor system can be adjusted to measure multiple types of defects. Each sensor in system is controlled by on-board computer, which adjusts size, strength, and angle of signals. Pipeline inspection gauge processes and stores data on-board. |
(Showing headlines 41 - 60) 1 2 3 4 5 6
|
|
|
|
 |