 Refrigerated Air Dryers filter compressed air.Airtek
Lancaster, NY 14086
Jun 06, 2002 Magnum SC and CT Series remove water and water vapor from compressed air. CT has multi-stage separator-coalescing filter installed after chiller to remove oil, water, and particulate contaminants. Both have Smart Cycle® demand control system and control center with flow schematics and digital telemetry for remote analysis of dryer performance. Dryers are available in 10 models from 2,500 to 18,000 scfm. Both can be built for flow rates up to 50,000 scfm.
|
 Refrigerated Dryers keep compressed air dry.Van Air Systems, Inc.
Lake City, PA 16423 2095
Apr 10, 2002 RD Series refrigerated compressed air dryers remove moisture from indoor air lines while providing 35 to 38 deg F dew point, low pressure drops, and no heat exchanger freeze-ups at low loads. It has non-cycling refrigerant compressor, CFC-free R-22 refrigerant, and capacity control valve to maintain steady dew point when flows fluctuate. Models are available to handle flows from 10 to 3,000 scfm at 100 psig. Models under 40 scfm include built-in mechanical drain. |
 Refrigerated Dryers are enviromentally friendly.Kaeser Compressors, Inc.
Fredericksburg, VA 22404
Mar 14, 2002 Refrigerated Dryers, with capacities from 1000 to 3000 scfm, have working pressures of 200 psig (max). Smooth surface, tube-in-tube, copper heat exchangers resist fouling, and provide heat transfer. All units use R-404a refrigerant, and contain no CFC's. Filtered separator equipped with Filter Monitor is standard on all models. Units also include Demand Manager(TM) microprocessor control system, and electronic demand drain. |
 Refrigerated Dryers watch dewpoint to save energy.Van Air Systems, Inc.
Lake City, PA 16423 2095
Mar 12, 2002 EMD Plus Series avoids dew point fluctuations, thus providing dry, compressed air at lower energy cost. Controller signals compressor to stop when there is drop in compressed air temperature due to low flow conditions. Under such conditions, system retains ability to respond immediately to load increases. Models are available for flows of 40 through 25,000 scfm. All have digital dew-point readout and electric drain with panel-mounted controls. |
 Compressed Air Dryer works without heat.Deltech
Ocala, FL 34474
Jan 29, 2002 Hydrobloc HB Series heatless desiccant dryer provides ultra dry compressed air down to -100°F dewpoint. It includes maintenance free shuttle valves, high efficiency coalescing prefilter, and particulate removal afterfilter. Dryers are available in 17 models rated from 55 to 3,250 scfm. Non-lubricated switching valve works with 2 solenoid-operated purge valves.
|
 Air Dryer offers alternative to refrigerant technology.Parker Hannifin Corp., The Filtration & Separation Div.
Tewksbury, MA 01876
Jan 23, 2002 Balston Membrane Air Dryer will dry compressed air to dewpoints as low as -40°F at flow rates up to 100 SCFM. It has no moving parts and operates without attention. Coalescing prefiltration is employed immediately upstream of membranes to protect them from pipe scale, particulate, and liquids. Dryer requires no electrical connections, which makes it ideal for remote and point-of-use installations or for flammable and explosive applications.
|
 Heat Exchangers cool compressed air.Sullair Corporation
Michigan City, IN 46360
Dec 17, 2001 Models SR-125 to SR-3000 cool compressed air by mechanical refrigeration, removing moisture and assuring that none condenses downstream unless air is exposed to lower temperatures. They have integral demister moisture separator and two-pass air system. Compressed air is pre-cooled in aluminum-finned, cross-flow heat exchanger to reduce refrigeration load, resulting in more efficient refrigeration system. Models range from 5 to 3000 scfm. |
 Refrigerated Air Dryer has small footprint.Gardner Denver
Quincy, IL 62301
Dec 05, 2001 RHT Series dedicated high inlet temperature (up to 180°F) refrigerated air dryer features integrated separator/filter. Its design provides filtration of solid particulates to 3 microns, oil aerosols to 5 ppm, and gives 50°F pressure dew point for dry air. Using up to 30 HP reciprocating compressors, dryer is suitable for confined installations and light industrial facilities. |
 Air Dryers offer remote monitoring.Hankison International
Canonsburg, PA 15317
Dec 04, 2001 HPRplus Series refrigerated compressed air dryers have air flows of up to 3000 scfm. Acting as complete Air Treatment Stations, dryers deliver dry, oil-free, compressed air. Their design includes dryer and filter with HF Series Grade 9 Filter/Separator that removes bulk liquid and particulates to 3 microns. Refrigeration system features R404a refrigerant, low noise hermetic scroll compressors, and intelligent heat load sensing EDBV control system. |
Dry Air System can be placed at application.Domnick Hunter Inc.
Charlotte, NC 28269
Nov 19, 2001 Mini Pneudri Midas provides uninterrupted clean, dry, compressed air where needed. It incorporates high efficiency and particulate filters plus desiccant cartridge inside 1 module that lets contaminated, compressed air in and clean, dry air out. Unit is available with pressure dewpoints of –40° F or –100° F and flow rates of 3-20 scfm at 100 psig. Applications include CNC machines, CMMs, lasers, instrumentation, and processing equipment.
|