Quantcast
 
Search for: Search what?
Nov 25, 2009  
 Sections
Latest New Product News
Industry Market Trends
Green & Clean News
Association & Government News
Adhesives and Sealants
Agricultural and Farming Products
Architectural and Civil Engineering Products
Automatic ID
Chemical Processing and Waste Management
Cleaning Products and Equipment
Communication Systems and Equipment
Computer Hardware and Peripherals
Construction Equipment and Supplies
Controls and Controllers
Display and Presentation Equipment
Electrical Equipment and Systems
Electronic Components and Devices
Explosives, Armaments and Weaponry
Fasteners and Hardware
Fluid and Gas Flow Equipment
Food Processing and Preparation
Health, Medical and Dental Supplies and Equipment
HVAC
Labels, Tags, Signage and Equipment
Laboratory and Research Supplies and Equipment
Lubricants
Machinery and Machining Tools
Material Handling and Storage
Materials and Material Processing
Mechanical Components and Assemblies
Mechanical Power Transmission
Mining, Oil Drilling & Refining
Mounting and Attaching Products
Non-Industrial Products
Optics and Photonics
Packaging Products & Equipment
Paints and Coatings
Plant Furnishings and Accessories
Portable Tools
Printing and Duplicating Equipment
Retail and Sales Equipment
Robotics
Safety and Security Equipment
Sensors, Monitors and Transducers
Services
Software
Test and Measuring Instruments
Textile Industry Products
Thermal and Heating Equipment
Timers and Clocks
Transportation Industry Products
Vision Systems
Waste Handling Equipment
Welding Equipment and Supplies
 Press Releases
Products in the News
Company News
Mergers & Acquisitions
People in the News
Literature & Websites
 Resources
News Delivery Options
Browse Categories
Browse Companies
Mobile Edition
PR Resources
Licensing
Advertising
How to Write an effective Press Release
Trade Associations
Small Business Support
MEP

Advertisement
Electronic Components & Devices -> Electronic Amplifiers -> Instrumentation Amplifiers -> Gauging Amplifiers


Gauging Amplifiers


   Add to Google      PDF icon



(Showing headlines 1 - 11)   
Strain Gage Amplifiers survive heat, shock, and vibration.

Strain Gage Amplifiers survive heat, shock, and vibration.

RAETECH Corporation
Ann Arbor, MI 48108
Apr 14, 2009 Measuring 18 x 9.7 x 4.4 mm, Miniature Strain Gage Amplifiers accept 8-36 Vdc power while providing 5 V bridge excitation and 0.1-4.9 V output. Users can program gain, offset, and temperature compensation from personal computer. Programming is done through power and signal leads, eliminating need for additional wiring. Rated from -40 to +125°C, amplifiers are suited for automotive, transportation, aerospace, robotic, and bio-med industries.

Amplifier suits strain gages and strain gage transducers.

Amplifier suits strain gages and strain gage transducers.

RDP Electrosense, Inc.
Pottstown, PA 19465
May 28, 2008 Fully isolated and EMC-compliant, DR7DC is designed to avoid potential ground loop noise problems. It offers shunt calibration with remote operation and provides acceptable solution when integrating industrial load cells and pressure sensors into control system. Operating from 9-36 Vdc, DIN rail-mount product can be configured for 0-10 V, +10 V, or 4-20 mA outputs from 4 mV to 10 V input signals. Transducer excitation is adjustable from 3-10 Vdc, and non-linearity is 0.02% FS.

Signal Conditioner/Amplifier accepts high level signals.

Signal Conditioner/Amplifier accepts high level signals.

Vishay Intertechnology, Inc.
Malvern, PA 19355 2143
Jun 06, 2005 With frequency response of 110 kHz, Model A2 features digital control of system instrumentation and monitoring of 10 Vdc analog outputs, both locally on control panel and remotely by Ethernet from PC. Embedded web server is scalable in multiples of 8 channels to maximum of 128. All system, card, and channel settings are accessible using HTTP commands or GUI provided by system. Model A2 is designed for strain gages, strain-gage-based transducers, and thermocouples.

Measurement Amplifier optimizes press-fit accuracy.

Measurement Amplifier optimizes press-fit accuracy.

HBM, Inc.
Marlborough, MA 01752 3014
May 20, 2005 Model MP85 facilitates 2-channel monitoring by checking 2 inter-related signals. Almost any sensor can be connected to amplifier, including strain gage sensors, inductive or incremental transmitters, and SSI transducers. Model MP85 uses algorithms for curve evaluation with max of 9 predefined windows for each curve, or 1 master curve with envelope as evaluation criteria. Digital I/Os save statistics on component quality, either on PC or internal MMC card.

Signal Conditioner features in-line design.

Signal Conditioner features in-line design.

PCB Piezotronics Inc.
Depew, NY 14043 2495
Dec 11, 2003 Model 8160A provides regulated, strain gage excitation voltage and delivers both voltage and current mode output signals for recording, control, or analysis purposes. It incorporates zero and span adjustments via screwdriver-adjustable potentiometers. Product is used with strain gage load cells and reaction torque sensors. In-line design makes it convenient for PLCs and computer-based data acquisition systems.

Strain-Gage Signal Conditioner suits low-level signals.

Strain-Gage Signal Conditioner suits low-level signals.

Calex Mfg. Co., Inc.
Concord, CA 94520
Nov 26, 2002 Model 163MK accommodates ¼, ½, and full wheatstone bridge strain gage applications and includes 2 built-in precision ½ bridge completion resistors. Product offers high-gain differential amplifier, 2-pole Butterworth filter, and built-in excitation supply capable of providing up to 120 mA. Gain can be set up to 5,000, amplifier output is ±10 V, and output filter cutoff frequency can be set at 10 Hz, 100 Hz, or 1 kHz via on-board DIP switch.

Load Cell includes amplifier/conditioner.

Load Cell includes amplifier/conditioner.

Transducer Techniques
Temecula, CA 92590
Sep 09, 2002 MLC Series (Mini Load Column) Compression Only Load Cell, constructed from stainless steel, is offered in range from 2,000 to 30,000 lbs. It mounts in shallow, machined flat pocket or smooth, flat surface, either free or fastened via bottom, tapped hole. Model TM0-1, 12 Vdc powered Amplifier/Conditioner Module, provides dedicated conditioning and several units can be powered from common power supply. Balance and span pots are low-tempco metal film for stability.

Amplifier conditions strain gages and load cell sensors.

Amplifier conditions strain gages and load cell sensors.

Phoenix Contact
Harrisburg, PA 17111 0100
Aug 14, 2002 MCR-Strain Gage amplifier module includes 1,000 V 3-way galvanic isolation between power supply, input, and output circuits. It supports strain gages/load cells with resistances from 120 to 20,000 ohms. Module filters and conditions signals to eliminate unwanted signal noise with DIP switch selectable cutoff frequencies of 30 Hz or 5,000 Hz. Outputs are provided for voltage (0–10, ±10, 0–5, or ±5 volts), and current loop (4–20 mA) operation.

Strain Gage Amplifiers are adjustable over wide range.

Strain Gage Amplifiers are adjustable over wide range.

Sensotec, Inc.
Columbus, OH 43228
Jun 24, 2002 Universal Series in-line strain gage transducer amplifiers have field selectable excitation voltage and wide adjustable gain range, making them suitable for transducers with sensitivities from 0.5-10 mV/V. Metal enclosure provides NEMA 4 or IP65 protection. Outputs include ±5 Vdc, ±10 Vdc, and 4-20 mA. They have 2 wire connections for high resistance strain gage bridges, and 3 wire connections for 350 Ohm bridges. Options include quick disconnect metal plug and molded cable.

Amplifier conditions strain gages and load cells.

Amplifier conditions strain gages and load cells.

Phoenix Contact
Harrisburg, PA 17111 0100
Apr 22, 2002 MCR-Strain Gage amplifier supports strain gages/load cells with resistances from 120 to 20,000 ohms. It includes 1000 V, 3-way galvanic isolation between power supply, input, and output circuits. Module filters and conditions signals to eliminate unwanted signal noise with DIP switch selectable cutoff frequencies of 30 or 5000 Hz. Outputs are provided for voltage (0 to 10, +/-10, 0 to 5, or +/-5 V), and current loop (4 to 20 mA) operation.

Amplifier/Conditioner offers side load rejection.

Amplifier/Conditioner offers side load rejection.

Transducer Techniques
Temecula, CA 92590
Apr 19, 2002 System combines SW0 (universal/tension or compression) and TM0-2 (stand alone bench top amplifier/conditioner), and is suitable for industrial and OEM force measurement and weighing applications. TM0-2 provides excitation, balance, and span adjustment via precision 10 turn pots and shunt calibration. SW0 load cell is offered in ranges from 1,000 to 50,000 lbs.




(Showing headlines 1 - 11)   


ThomasNet News Advertisers




Home  |  My ThomasNet News  |  Industry Market Trends  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2009 Thomas Publishing Company
Terms of Use - Privacy Policy