Electronic Components & Devices ->
Electronic Amplifiers ->
Instrumentation Amplifiers
Instrumentation Amplifiers
(Showing headlines 1 - 20) more ....
|
 Instrumentation Amp, Bandpass Filter enables flexible DAQ.Alligator Technologies
Costa Mesa, CA 92627
Jan 19, 2012
As single-channel, programmable signal conditioning instrumentation amplifier and band pass filter, USB-controllable USBPBP-S1(TM) comes in range of filter characteristics. Intelligence is built in to configure module from power-up and operate independently in Turn-Key or host computer controlled scenario. Compatible with 12, 16, or 24-bit A/D devices, module lets user mix and match filter characteristics and independently select and program high/low pass corner frequency and gain steps.
|
 Strain Gauge Signal Amplifier features CE approval.FUTEK Advanced Sensor Technology, Inc
Irvine, CA 92618
Oct 26, 2011
Compliant for all medical, industrial, and consumer applications, CSG110 is available in 1 or 10 kHz bandwidth versions and supports modification to support 25 kHz option. RoHS-compliant product, designed for minimal noise output, features short-circuit and over-voltage protection, comes in ABS-94HB black enclosure, and features DB9 connectors. Enclosed with DIN rail mount, product is constructed with DIP switches instead of soldered internal components.
|
Passive 3D Viewing Kit targets professional A/V market.Flexible Picture Systems
Richmond Hill Canada
Sep 19, 2011
Based on video scalers with Geometry Correction and Edge Blending, Image AnyPlace-3D creates fully immersive, passive 3D viewing that can be scaled to fit any projection screen size and accommodate any number of viewers. Passive system utilizes separate and simultaneous polarization for each eye for comfortable viewing experience. Kit includes 2 signal processors, HDMI distribution amplifier, HDMI cables, polarizing filters and glasses, IR remote control, and rack mounts.
|
Instrumentation Amplifier features low -130 dB distortion.Analog Devices, Inc.
Norwood, MA 02062-9106
Jun 29, 2011
Featuring current feedback architecture that offers 15 MHz (G=1) bandwidth and 22 V/µs slew rate, Model AD8429 measures extremely small signals in noisy industrial environments. Device operates across extended industrial temperature range of -40 to 125°C with 1-nV/√Hz input noise and 45-nV/√Hz output noise. Housed in 4 x 5 mm SOIC_N package, Model AD8429 has 90 dB CMRR when operating in dc mode and 80 dB CMRR in ac mode, which prevents unwanted signals from corrupting smaller signal acquisition.
|
 High Frequency Amplifiers features single-drawer design.Instruments For Industry, Inc.
Ronkonkoma, NY 11779
Mar 28, 2011
Supporting frequency range of 1.0-18.0 GHz, S/T 20 Series features compact design in single drawer measuring 7 x 19 x 24 in., depending on power level and options. Applications include MIL-STD-461/462, RTCA/D0-160, SAE Specifications, Radiated Susceptibility, Bellcore testing, and broadband communications.
|
Instrumentation Amplifier operates in environments to 210°C.Analog Devices, Inc.
Norwood, MA 02062-9106
Mar 14, 2011
Over its operating range of -55 to +210°C, AD8229 features CMRR of 100 dB, input voltage offset that varies by 100 nV/°C, and input noise of 1.0 nV/sqrt Hz. Latter makes amp suited for sensors that read faint signals. Gain can be set with single resistor, and additional features include 45 nV/sqrt Hz output noise, 15 MHz bandwidth, 25 V/µsec slew rate, THD of 120 dB at 1 kHz, and ±4 to ±18 V dual supply.
|
 Process Controllers are available with software interface.HBM, Inc.
Marlborough, MA 01752 3014
Oct 14, 2010
Used for monitoring press-fitting processes or implementing switch checks, respectively, MP85A FASTpress and MP85A-S EASYswitch utilize software interface for connection to IPM process data management software. Controllers can be seamlessly integrated into appropriate system via IPM interface so that acquired production data can be directly transmitted to quality assurance server for visualization and archiving. In addition, data can be observed in real-time via web browser.
|
Thermocouple Amplifiers feature cold junction compensation.Analog Devices, Inc.
Norwood, MA 02062-9106
Jun 07, 2010
Designed for K- and J-type thermocouples, Series AD849x includes 4 models that convert small voltages generated by thermocouple junction into 5 mV/°C analog signal that can be read by ADC or microcontroller. Common-mode rejection of 0.1°C/V allows devices to reject common-mode noise that may be associated with long lead thermocouples. Operating off variety of voltages from single 2.7 V to dual ±18 V supplies, amplifiers consume 180 µA quiescent supply current.
|
 MIL Grade Strain Gage Amplifier suits aircraft applications.Columbia Research Labs., Inc.
Woodlyn, PA 19094
May 04, 2010
Designed for DT and DTD series of full bridge strain sensors, military grade Model 5802 provides strain and temperature outputs from sensors monitoring critical aircraft undercarriage structure and surfaces for potential fatigue damage. Strain output incorporates microprocessor driven auto zeroing circuit capable of compensating for input offests, allowing operator to correct for any strain offsets resulting from gage mounting, material fatigue, or material deformation.
|
 Instrumentation Amplifier includes on-chip diagnostics.National Semiconductor Corp.
Santa Clara, CA 95051-0695
Apr 09, 2010
By allowing users to detect shorts, open circuits, and degraded source connections in remote industrial applications, Model LMP8358 facilitates pressure and thermocouple bridge measurements. Zero-drift, programmable amplifier operates from single 2.7-5 V supply, providing 10 µV max offset voltage and 50 nV/C max offset voltage drift. Supplied in 14-pin SOIC and TSSOP packages, amplifier features gain bandwidth of 8 MHz while consuming 1.7 mA of supply current.
|
 Universal Amplifier has 4 individually configurable channels.HBM, Inc.
Marlborough, MA 01752 3014
Apr 09, 2010
Supporting up to 15 different transducer types per channel, 4-channel MX440A features electrically isolated input channels, each providing one 24 bit analog-to-digital converter. Individually configured output channels can be used for measuring wide range of mechanical, thermal, or electrical quantities. Suited for wide range of applications, universal amplifier offers Ethernet TCP/IP and automatic configuration allowing for quick connection to PC.
|
Distribution Amplifier switches 2 sources to multiple HDTVs.Atlona Technologies
San Jose, CA 95131
Mar 22, 2010
Designed to work as splitter for all HD video applications, Model AT-HD-V214 features 2 HDMI 1.3 inputs and 4 HDMI 1.3 mirrored outputs, allowing any digital video source with HDMI outputs to connect to upwards of 4 simultaneous HD displays. HDCP-compliant device can send HD signals at resolutions up to 1080p or 1,920 x 1,200 and data rates up to 6.75 Gbps, with no signal or picture degradation. Control options include front panel, RS232, and IR remote.
|
DisplayPort-Based IC cleans and amplifies video signals.Integrated Device Technology, Inc.
Santa Clara, CA 95054
Oct 26, 2009
Offering signal quality enhancements when transmitting display signals over extended distances and inefficient board layouts, PanelPort(TM) LinkXtend(TM) provides unlimited cable extension for PCs and mobile computers to connect to monitors and projectors. DisplayPort(TM)-based single-chip device amplifies and re-drives signals while also cleaning, reconditioning, and renewing signal integrity. It also provides full link layer repeat functionality while extending DisplayPort signal capability.
|
Distribution Amplifier works as VGA video splitter.Atlona Technologies
San Jose, CA 95131
Oct 16, 2009
Providing 1 VGA input and 16 VGA outputs, Model AT-VGA116 is capable of splitting any signal from 1 VGA source to 16 separate displays with compatible VGA inputs simultaneously. Device allows cascading of up to 24 units to meet any AV application. With max bandwidth of 1 GHz, splitter will support highly defined video in multiple resolutions up to 2,048 x 2,048. Applications include store video displays, education and worship facilities, and digital signage.
|
 Power Amplifiers target EMC testing applications.Instruments For Industry, Inc.
Ronkonkoma, NY 11779
Oct 13, 2009
Available at power levels from 10-500 W, IFI CMC300 Series provides minimum of 300 W of CW power for 10 MHz to 1.0 GHz frequency range. Single-drawer units feature compact design measuring 10.5 in. H (depending on power level and options) x 19 in. W x 25.25 in. D. Amplifiers are suited for high power test requirements for pre-compliance testing, EMC testing, and all lab and test installations.
|
Amplifier provides radiated susceptibility testing.Instruments For Industry, Inc.
Ronkonkoma, NY 11779
Sep 21, 2009
Solid-state SMXE-200-2G Series power amplifier provides minimum of 200 W of CW power for frequency range of 10 KHz to 2.0 GHz. Measuring 19 x 10.5 x 27 in. and weighing 60 lb, compact, solid-state power amplifier simplifies EMC and other RF/Microwave testing for low-to-high power test applications. It can also be used for pre-compliance testing, as well as all lab and test requirements.
|
HD/SDI Distribution Amplifiers suit broadcast applications.Atlona Technologies
San Jose, CA 95131
Jul 09, 2009
Available with support for SDI and HD-SDI standards, 1 x 4 splitter AT-SDI-14, 1 x 4 splitter with re-clocking AT-SD-14RC, 1 x 6 splitter AT-SDI-16, and 1 x 6 splitter with re-clocking AT-SDI-16RC take single input and distribute signal perfectly to 4 or 6 identical outputs. Re-Clocking technology helps buffer and cascade long distance transmissions to send signal over 1,000 ft with resolutions up to 1,080p and full bandwidth up to 1.48 Gbps. Models also support audio.
|
 Instrumentation Amplifier targets DAQ applications.Alligator Technologies
Costa Mesa, CA 92627
Jun 25, 2009
Compatible with all 12, 16, or 24-bit A/D devices, USB-controlled, single-channel Model USBPGF-S1(TM) consists of programmable signal conditioning instrumentation amplifier and low pass filter. Users can mix and match filter characteristics and independently select and program AC or DC coupling, corner frequency, and gain steps up to x1000 in single-ended or differential measurements. Each can be configured as 8-pole Butterworth, Bessel, elliptic, or linear phase filter.
|
Universal Amplifier has up to 96 kHz/channel sampling rate.HBM, Inc.
Marlborough, MA 01752 3014
Jun 08, 2009
Supporting Advanced Plug and Measure technology that allows applicable transducers to be automatically recognized by amplifier, MX410 has 4 individually configurable inputs, each electrically isolated and each with analog output. Digitalization is implemented with 24 bit resolution. Module is suitable for SG transducers in half or full bridge circuits, inductive half or full bridges, current-fed piezoelectric sensors (IEPE), and analog voltage signals (±10 V).
|
Frequency Amplifier can acquire up to 4 frequency signals.HBM, Inc.
Marlborough, MA 01752 3014
Jun 08, 2009
With sampling rates of up to 96,000 signals/sec and bandwidths of up to 38 kHz, MX460 can acquire torque from HBM torque transducers, PWM signals, and speeds. It measures digital signals with precision of up to 1 MHz, while all input channels are electrically isolated and can be individually configured. Device supports integrated Transducer Electronic Data Sheet (TEDS) technology and features Ethernet and Firewire interfaces for data transmission.
|
(Showing headlines 1 - 20) more ....
|
Latest Products in the News |
FSR Metal Products - May 17, 2012 FSR to Launch Enhanced High-Resolution 1 X 2 Computer Distribution
Bruel & Kjaer - August 11, 2011 Meet Brüel & Kjær at Autumn Events
More Products in the News...
|
|
|