Electrical Grounding Connectors
(Showing headlines 1 - 10)
|
 Connectors terminate communication grounding conductors.ILSCO
Cincinnati, OH 45227 1426
Oct 06, 2008
UL-listed and meeting UL467 specifications and NEC Article 250.94, GBT lay-in intersystem grounding and bonding termination connectors accommodate from 250 kcmil-#8 AWG grounding electrode conductors. Units are designed for copper or aluminum conductor and install on ground electrode conductor below meter or panel. They include 4 x #2-14 AWG bonding taps, lay-in feature, stainless steel screws, and serrations in conductor wire way to minimize oxidation.
|
 Grounding Tails come in 1-gallon pail.Ideal Industries, Inc.
Sycamore, IL 60178
Aug 13, 2008
Supplied in re-closable pail, Pail-o-Tails includes five hundred 6.5 in., 12 AWG solid wire grounding tails. Pail is built to withstand elements, and moves with contractor from one jobsite to another without spilling or allowing dirt and moisture inside to damage tails. Once emptied, pail can be used to hold any number of additional supplies.
|
Grounding Clip and Cabling suit solar power installations.Tyco Electronics Corp.
Harrisburg, PA 17105-3608
Aug 29, 2007
Providing grounding for solar panels and related products, SolKlip Connectors have 4 points of electrical contact and are suited for use with 12-10 AWG uninsulated copper wire. They can be installed with pliers and Phillips screwdriver and can be reused several times. Made from high conductivity copper alloy, Solar AWG Cable provides UV resistance in outdoor PV and solar panel installations. It is available in 500 or 1,000 ft reels in 10, 12, or 14 AWG wire size.
|
 Shaft Grounding Ring includes aluminum mounting adaptor.Electro Static Technology
Mechanic Falls, ME 04256
Aug 22, 2006
Designed for NEMA and IEC ac motors, AEGIS SGR(TM) Conductive MicroFiber(TM) Shaft Grounding Ring prevents bearing damage by dissipating shaft currents to ground. Conductive microfibers inside provide path of least resistance, allowing shaft currents to discharge safely to motor frame. Microfibers work with virtually no friction or wear and are unaffected by dirt, grease, or other contaminants. Secured with 3 mounting screws, mounting adapter holds SGR in place beyond protrusion.
|
 Power Connectors withstand extreme environmental conditions.FCI/Burndy Products
Manchester, NH 03108
Nov 02, 2005
Made of high copper content alloys, Mechanical Grounding/Power Connectors are suited for direct burial applications in earth or embedment in concrete. Units feature nut and bolt design to provide means for connecting copper cable to various applications.
|
Fittings feature snap-in design.Bridgeport Fittings, Inc.
Stratford, CT 06497
Aug 11, 2005 Made of die-cast zinc, WHIPPER-SNAPâ„¢ Connectors feature hardened spring steel locking ring that eliminates need for locknut and installs in seconds. Double locking tabs hold connector tight in box, while additional tension tabs provide continuity and clear wire path. Push-through design eliminates snags and wire damage. WHIPPER-SNAPâ„¢ connectors are UL listed for grounding when installed in accordance with NEC, and are suitable for health care facilities. |
 Grounding Connector suits parallel-through applications.ERICO, Inc.
Solon, OH 44139-2631
Nov 23, 2004 ERITECH® HAMMERLOCK joins grounding conductor to ground rod with one hammer strike. Machined from electrolytic copper, connection is conductive and withstands ground fault currents and lightning transients. Dual-hole version, available for No. 6 and No. 4 solid, is suited for pad-mounted transformer applications. Larger version of single-hole product permits 2/0 stranded to be joined to 5/8 in. and ¾ in. ground rods. Both withstand harsh underground environments. |
 Wire Bonding Islands offer alternative to long wire bonding.Florida RF Labs Inc.
Stuart, FL 34997
Aug 09, 2004 Gold-plated, Wire Bonding Islands can be mounted between 2 components being wired together using shorter wire leads, reducing overall parasitics in circuit. Units feature option of using tab for connection to circuit with standard thickness of 0.015 in. Made from alumina substrate, devices feature wire-bondable gold conductor, silver ground plane, and gold-plated, beryllium copper tab contact. |
 Power and Grounding Connectors meet UL and CSA requirements.Panduit Corp.
Tinley Park, IL 60477 3091
Dec 23, 2003 PAN-LUGâ„¢ copper compression lugs and splices meet NEBS Level 3 requirements. PAN-LUG Copper HTAP System features slotted design and snap-on clear cover that allows 360° inspections of crimped connection to assure crimp is complete and correct die was used. Other PAN-LUG products include Copper In-Line Reducing Splices, Copper CTAPs, Lugs for No. 8 AWG - 777.7 kcmil Flex Wire, Lugs for No. 14–10 AWG Wire and Expanded Range for No. 4 AWG Lugs. |
 Conduit Connectors integrate grounding lugs.O-Z/Gedney A Business Of The EGS Electrical Group
Tulsa, OK 74145
Jan 23, 2003 For use with liquid-tight, flexible, metal conduit, Ground-Tite® connectors have grounding lug cast as part of gland nut for ground-fault withstand capability. Lugs terminate bonding conductor run externally across conduit, according to UL and CSA requirements. Windows in long ferrule allow contractor to inspect for full engagement. Connectors are available in 45° and 90° models from 3/8–5 in., and in straight designs from 3/8–6 in. |