Quantcast
Search for: Search what?
Aug 21, 2008  
 Newsletters
Subscribe Free to Product News Alerts
  
Receive customized, daily news on the products you want.
Subscribe   View Sample
 Categories
Industrial Market Trends
OnSite WebReviews
Latest New Product News
Adhesives and Sealants
Agricultural and Farming Products
Architectural and Civil Engineering Products
Automatic ID
Chemical Processing and Waste Management
Cleaning Products and Equipment
Communication Systems and Equipment
Computer Hardware and Peripherals
Construction Equipment and Supplies
Controls and Controllers
Display and Presentation Equipment
Electrical Equipment and Systems
Electronic Components and Devices
Explosives, Armaments and Weaponry
Fasteners and Hardware
Fluid and Gas Flow Equipment
Food Processing and Preparation
Health, Medical and Dental Supplies and Equipment
HVAC
Labels, Tags, Signage and Equipment
Laboratory and Research Supplies and Equipment
Lubricants
Machinery and Machining Tools
Material Handling and Storage
Materials and Material Processing
Mechanical Components and Assemblies
Mechanical Power Transmission
Mining, Oil Drilling & Refining
Mounting and Attaching Products
Non-Industrial Products
Optics and Photonics
Packaging Products & Equipment
Paints and Coatings
Plant Furnishings and Accessories
Portable Tools
Printing and Duplicating Equipment
Retail and Sales Equipment
Robotics
Safety and Security Equipment
Sensors, Monitors and Transducers
Services
Software
Test and Measuring Instruments
Textile Industry Products
Thermal and Heating Equipment
Timers and Clocks
Transportation Industry Products
Vision Systems
Waste Handling Equipment
Welding Equipment and Supplies
Association News
Browse Categories
Browse Companies
 Press Releases
Products in the News
Company News
Mergers & Acquisitions
People in the News
Literature & Websites
 Resources
News Delivery Options
Mobile Edition
PR Resources
Licensing
Advertising
How to Write an effective Press Release
Trade Associations
Small Business Support
MEP

Advertisement
Electrical Equipment & Systems -> Electrical Transmission & Switching -> Relays -> Protection Relays


Protection Relays


   Add to Google      PDF icon



(Showing headlines 1 - 18)   

Distribution Controller helps reduce power outage times.

Schweitzer Engineering Laboratories Inc.
Pullman, WA 99163
Aug 06, 2008 SEL Distribution Automation Control System analyzes and detects permanent fault conditions such as broken jumpers, loss of substation source, and lockout due to miscoordinated protective devices, isolates affected feeder sections, and restores power to unaffected sections to reduce outage times. With ability to automate up to 6 sources and 100 devices, system includes drag-and-drop IEC 61131 function block configuration software on SEL information processor.

Digital Relays comply with ANSI standards.

Digital Relays comply with ANSI standards.

Schneider Electric
Palatine, IL 60067-7399
Oct 15, 2007 Featuring modular design with plug-and-play DIN rail mount options, Square D® SEPAM Line includes Series 80 for critical sources and loads, Series 40 for important sources and loads, and Series 20 for basic source and load requirements. Units feature graphical software package for programming, and backlit LCD display that allows multi-line text plus graphics. Display lets users view multiple metered values, as well as alarm and diagnostic functions.

Relay/Monitor helps predict motor failure.

FCI Automation
Grand Rapids, MI 49548
Oct 08, 2007 Designed to work as overload relay and motor system monitor, MOTOR+MEDIC provides diagnostic information needed to recognize impending motor failure or conditions that will lead to motor failure if not resolved. Included software suite allows user to sample motor's health on steady or periodic basis. In addition to low and high voltage, MOTOR+MEDIC protects 3-phase motors from low and high current, current and voltage imbalance, and ground fault.

System protects MV to EHV transmission lines.

GE Multilin
Markham, ON L6E1B3  Canada
Oct 01, 2007 Utilizing dual algorithms, D90Plus sub-cycle distance relay features true convergence of multiple functions, including automation and control, digital fault recording, communications, and local HMI capabilities. Advanced automation engine with user programmable logic provides millisecond deterministic execution rates, irrespective of program size. With 128 samples/cycle multi-channel analog and digital recorder, virtually all transients and long term events can be recorded and viewed.

Generator Protection System uses Synchrophasor technology.

GE Multilin
Markham, ON L6E1B3  Canada
Aug 13, 2007 Designed to protect and control medium to large-sized ac generators, Model G60 supports Synchrophasor technology, which allows power providers to monitor how instabilities are affecting points of generation. Measurements are updated every 16.67 ms, providing critical recording of power system disturbances. Accumulated Over/Under frequency protection monitors amount of time generator has been running at off-nominal frequencies and triggers alarms indicating maintenance is required.

Motor Protection Relay offers multiple metering and relaying.

Eaton Corp.
Cleveland, OH 44114
Jul 17, 2007 Conforming to UL 1053 ground fault protection standard, Cutler-Hammer® MP-4000 motor protection relay offers protection, fault diagnostics, power metering, and communication options such as Modbus RTU and Device Net. Voltage Transformer inputs enable protection functions and metering such as under/over voltage, negative sequence voltage, power factor, and frequency. Relay features Intel-I-Trip algorithm, voltage sag ride-through at 20 cycles, and motor start profile.

Overload Relay provides continuous motor protection.

Siemens AG
Munich D-80333  Germany
Apr 08, 2005 Sirius 3RB2 electronic overload relay permits continuous motor and plant protection from 0.1-630 A. When PTC sensor is connected, unit transmits directly to PLC for further processing. Relays are electronic and mechanical units with dimensions matched to other components of Sirius modular system.

Monitoring Relay enables flexible use.

Siemens AG
Munich D-80333  Germany
Apr 08, 2005 Sirius 3UG4 monitoring Relay can be flexibly adapted using wide range of parameter settings such as: phase sequence, asymmetry, undervoltage or overvoltage, delay times, and reset response. Unit has wide voltage range of 160-690 V. Unit is equipped with a display. Indication of actual value and type of fault facilitates installation and fault diagnostics. Together with contactor reversing combination, relay automatically corrects an incorrect phase sequence.

Relay protects 3-phase motors from thermal overload.

Relay protects 3-phase motors from thermal overload.

Schweitzer Engineering Laboratories Inc.
Pullman, WA 99163
Oct 13, 2004 Model SEL-749M protects against nuisance tripping while enabling release of maximum horsepower. True Temperature-Based Thermal Overload Model tracks heating effects of load and current imbalance while motor is accelerating and running, thereby handling all motor operation scenarios. Adaptive Overcurrent Element technology enables unit to protect against high fault-current conditions when Current Transformer saturation is present.

Differential Relay eliminates need for settings.

Differential Relay eliminates need for settings.

Schweitzer Engineering Laboratories Inc.
Pullman, WA 99163
Jul 07, 2004 Microprocessor-based SEL-387L Line Current Relay suits applications with identical-ratio CTs at both ends of line, with digital communications channel interface between relays. Restraint technology provides secure, high-speed ground fault differential and sensitive phase protection, uncompromised by communication asymmetry, CT saturation, or different in-feeds. Negative- and zero-sequence differential elements detect high-resistance ground faults while remaining secure for external faults.

Differential Relay suits transformer applications.

Differential Relay suits transformer applications.

Cooper Power Systems
Waukesha, WI 53188
Feb 20, 2003 Incorporating selectable transformer winding configuration, selective tripping of high/low-side breakers, and breaker health monitoring, iXP-420 also includes Virtual Test Set™ event record simulator. Protection features include over-excitation (V/Hz), under/over-voltage, phase overcurrent, negative-sequence overcurrent, and breaker fail-to-trip/fail-to-close indicators. Unit comes with IDEA Workbench™ graphical software-programming environment.

Relays enhance machine monitoring.

Rockwell Automation
Milwaukee, WI 53204
Dec 31, 2002 MachineAlert(TM) function protection relays include phase monitors, current monitors, thermistor monitors, and motor rotation monitors. Microprocessor technology combined with solid-state circuitry provides repeatable operation. LCD keypad programming takes guesswork out of device set up. Motor control enhancing functions of relays protect equipment and monitor applications to help reduce equipment damage and production downtime.

Electronic Overload Relay protects motors.

Electronic Overload Relay protects motors.

Automatic Timing & Controls
Lancaster, PA 17605
Dec 04, 2002 Microprocessor-based, MotorGuardian™ MPA-1000 provides protection for 3-phase ac motors, pumps, and compressors. It installs in new or retrofit applications using 2-piece, clip-on current transformers. DIN-rail mount enclosure includes 2-line, 16-character, vacuum-fluorescent display.

Programmable Relays suit power distribution applications.

Programmable Relays suit power distribution applications.

Eaton Corp., Cutler-Hammer Group
Moon Township, PA 15108
Nov 18, 2002 Enclosed in NEMA Type 6 chemically treated, waterproof drawn-brass shell, MPCV Network Protector Communications Relays grant access to voltage, current, power, power factor, harmonics, and last trip information. Users select from 2 closing curves, including modified, circular, closed curve. Relays monitor network protector's internal enclosure for temperature, alarms of detected anomalies, and water. Waveform storage capability provides breaker information.

Relays protect utility equipment.

Relays protect utility equipment.

Electroswitch Electronic Products
Raleigh, NC 27604
Jul 24, 2002 Series 24 Type WL-2 and WL Lock-Out Relays feature manual-, electric-, or self-reset capability. Manual-reset LORs have nominal trip speed of less than 8 msec. Electric- and self-reset models are available in standard-speed (12 to 15 msec) or high-speed (8 msec or less) trip configuration. Maximum of 10 decks can be stacked in one relay, providing 2 N/O and 2 N/C contacts per deck. Contacts are rated at 60 A for 1 min and 30 A for continuous current.

Generator Relay protects against abnormal conditions.

Generator Relay protects against abnormal conditions.

Schweitzer Engineering Laboratories Inc.
Pullman, WA 99163
Jul 02, 2002 SEL-547 Distributed Generator Interconnection Relay provides utility-grade protection when using generator in all operating modes including peak shaving, base loading, islanding, and emergency backup. Relay provides most basic generator protection functions recommended by IEEE Standard P1547 including over/under voltage detection for single or 3-phase, over/under frequency detection, synchronism check, reverse phase, and reverse power protection.

Protection Relay monitors 2-winding transformers.

Protection Relay monitors 2-winding transformers.

Schweitzer Engineering Laboratories Inc.
Pullman, WA 99163
Jun 11, 2002 SEL-387A monitors and protects transformers and other 2-port electrical apparatus. Protection includes differential and overcurrent protection for 3-phase current inputs, and optional Restricted Earth Fault function. Four serial communications ports enable remote metering and control of system functions and settings via PC. Sequential-events recorder logs all changes of state within relay logic elements, providing data regarding events and conditions leading up to events.

Circuit Monitor detects oscillatory and impulsive transients.

Circuit Monitor detects oscillatory and impulsive transients.

Square D Co.
Palatine, IL 60067
Feb 12, 2002 POWERLOGIC® Series 4000 permanently mounted circuit monitor with transient detection (CM4000T) automatically generates alarm so that action may be taken to correct problems before facility shuts down. It detects and captures oscillatory and impulsive transients (up to 10,000V peak, line-to-line) as short as 1 microsecond in duration. CM4000T maintains historical record of number of transients per phase, magnitude, duration and time of occurrence.




(Showing headlines 1 - 18)   


Category Advertisements


Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2008 Thomas Publishing Company