Electrical Equipment & Systems
(Showing headlines 9421 - 9440) << 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 ...
|
 Transformers measure current levels up to 30 A.Zettler Magnetics, Inc.
Aliso Viejo, CA 92656
Mar 07, 2006
Intended for PCB mount applications, Series ACST-200 features wide range of primary to secondary turn's ratios and is optimized for near linear output voltage vs input current. Bobbin holds primary winding to ensure consistent mounting position, and allows isolation voltage up to 3,000 V. Units are lead-free and feature UL approved Class B insulation system.
|
 LED Illuminated Switches suit front panel applications.Lumex Inc.
Carol Stream, IL 60188
Mar 07, 2006
Chroma LED(TM) SPST Switches are available in variety of colors and styles. Offered with round and square bezels, push-button units are rated 3 A at 125 Vac and 1.5 A at 250 Vac. Rocker-style switches come in rectangular, round, oval, and square versions, in thread-mount or snap-in styles. Low-voltage units are rated 12 Vdc at 25 A, while power-line voltage models are rated 125/250 Vac at 16/10 A. Round and rectangular toggle-action switches are rated 30 A at 12 Vdc, 10 A at 125 Vac, and 6 A at 250 Vac.
|
 GFCI can be used with up to 3 power tools.EGS Electrical Group
Skokie, IL 60077
Mar 07, 2006
Portable in-line triple-tap Ground Fault Circuit Interrupter (GFCI) detects and shuts off dangerous electrical currents in less than .025 sec. With 4-6 mA trip level, manual reset, and 120 V/15 A rating, it prevents injury or electrocution resulting from water, frayed insulation, or damaged power cords. GFCI offers 2 ft SJT 12/3 AWG cable with NEMA 5-15 plugs on line side and attached molded T-head power block of 3 NEMA 5-15 receptacles on load end.
|
Electronic HID Ballast supports ceramic metal halide lamps.Advance Div. of Philips Electronics North America
Rosemont, IL 60018
Mar 07, 2006
Measuring 4.4 x 1.3 x 1.2 in., e-Vision® Mini 39 W Ballast operates on line voltage of 120 V, 50/60 Hz with 90°C max case temperature rating and cold-start capability down to -20°F. Ballast incorporates range of safety features, including lamp end-of-life detection and thermal protection. It is suited for downlighting, track lighting, and accent lighting applications.
|
Battery suits material handling applications.Power-Sonic
San Diego, CA 92154
Mar 07, 2006
Maintenance-free, sealed lead acid battery, Model PS-62000 is designed specifically for pallet jacks and walkie stacker applications. Measuring 12.05 x 6.61 x 8.74 in., 6 V unit weighs 64 lb and has nominal capacity of 200 Ah at 10 hour rate. Height over terminals is 9.98 in.
|
Cable Tie Assembly has tamper-proof design.Device Technologies, Inc.
Southborough, MA 01772-1033
Mar 06, 2006
Push-Mount(TM) Cable Tie assembly features low profile that prevents snagging when cable is trimmed and harness is pulled through bulkhead. Remaining terminal end falls below low profile receptacle, eliminating sharp edges. Push-Mount Wire Tie has 50 lb tensile strength rating and operates in temperatures from -40 to 185°F. RoHS-compliant product snaps into panel sheet with max thickness of .135 in., providing clean, multi-tasking management solution.
|
Data Center Power Systems scale up to 60 kW per rack.American Power Conversion
West Kingston, RI 02892
Mar 06, 2006
Integrated InfraStruXure(TM) Systems provide UPS power, power distribution, and cooling in standardized rack-based architecture. InRow cooling solutions feature modular design that allows for placement within row of racks to provide predictable cooling infrastructure in data center. InfraStruXure Manager allows customers to proactively manage entire system from single management platform.
|
 Power Supplies offer output voltages from 3.3-54 V.Hitek Power
Santee, CA 92071
Mar 03, 2006
HTK Series of single-output, low-voltage, switch-mode power supplies offers choice of case type, output connectivity, and front panel. Featuring over-current, over-voltage, over-temperature, and short-circuit protection, they accept input from 90-264 V and have power factor correction to 0.99. HTK300 units offer max output power of 198 W for 3.3 V variant and 300 W for other variants, while HTK400 supplies have max output power of 264 W for 3.3 V unit, and 400 W for other units.
|
 Electronic HID Ballasts suit metal halide lamps.Advance Div. of Philips Electronics North America
Rosemont, IL 60018
Mar 03, 2006
Featuring IntelliVolt® multiple-voltage technology, e-Vision® Ballasts include 70 and 100 W Reduced-Profile models and 150 W Dimming model with 0-10 V dimming interface and dim ability to 60% lamp power. All ballasts feature 85°C max case temperature, as well as safety features, including automatic lamp power control and lamp monitoring. They are suited for downlighting and accent lighting applications within retail, commercial, institutional, and outdoor settings.
|
 I/O Bus Terminals control DC motors.Beckhoff Automation LLC
Minneapolis, MN 55337
Mar 02, 2006
Offering alternative to traditional drive systems, Model KL2532 can supply two 24 W DC motors with up to 1 A, while Model KL2542 can drive two 175 W DC motors with up 3.5 A continuous current. Model KL2542 includes output stage for up to 50 V operating voltage and permits short-term peak currents. It also offers option for direct connection of incremental encoder for each motor.
|
 Power Management IC suits handheld applications.Linear Technology Corp.
Milpitas, CA 95035
Mar 02, 2006
Featuring automatic input detection and selection, LTC3550-1 integrates linear Li-Ion battery charger that draws power from wall adapter or USB port. Charger delivers up to 950 mA charge current from wall adapter supply or 500 mA from USB supply using constant-current/constant-voltage algorithm, with final float voltage accuracy of ±0.6%. Product also integrates synchronous buck regulator that delivers up to 600 mA continuous output current and efficiencies up to 93%.
|
 Charge Pump drives main and camera LEDs in cell phones.Linear Technology Corp.
Milpitas, CA 95035
Mar 02, 2006
Manufactured in 3 x 3 x .75 mm QFN package, LTC3210 provides 5 LED current sources at up to 500 mA of total output current: 4 x 25 mA LED Main display and one 400 mA Camera LED display. Each display is digitally controlled with independent dimming and programming via single wire interface. This integrated, 800 kHz, 1x/1.5x/2x multimode charge pump has 2.9-4.5 V input range and exhibits efficiencies to 95% with quiescent current of 400 µA.
|
Medical Connector Contacts offer current ratings from 3-30 A.Synergetix
Kansas City, KS 66106
Mar 02, 2006
Medical Connector contacts can be incorporated in medical connector assemblies in normal environments as well as those used in harsh conditions with extreme temperatures, vibration, or impact. Available 12 different versions with various terminations, they feature overall length range of .173-.513 in. Contacts are suited for applications such as hearing aids, defibrillators, surgical instruments, MRI scanners, and docking stations.
|
EMI Filters target wireless handsets.California Micro Devices
Milpitas, CA 95035
Mar 02, 2006
Praetorian(TM) ASIP(TM) EMI Filter, Model CM1419 integrates spiral inductors with capacitors, diodes, and resistors on single chip, resulting in equivalent series resistance of 0.28 Ohms with minimal insertion loss in 5-bump CSP format. ESD diodes connected to filter ports safely dissipate ESD strikes of ±30 kV. Attenuation levels are greater than -40 dB in 800 MHz to 2.1 GHz frequency range. Model CM1418 features same electrical characteristics in larger 6-bump footprint.
|
Fuel Cell System provides critical backup power.Northwest Power Systems
Bend, OR 97701
Mar 01, 2006
Developed to address needs of telecommunications and UPS backup power needs, ElectraGen(TM)3 helps improve system reliability and lends to predictable performance in various climates. Hydrogen-based proton exchange membrane (PEM) fuel cell solution is CE-certified and produces up to 3 kW of clean backup power. Units have life expectancy of 10 years.
|
Coated Sleeving minimizes aeroengine fire risk.Busak + Shamban Great Lakes
Fort Wayne, IN 46803
Mar 01, 2006
Used on glass braided shielding for aeroengine applications, PTFE-based Turcon® Coating provides resistance to shearing and extreme heat. Aircraft fuel lines and steel clips can be sleeved in Turcon®-treated glass braiding to minimize surface friction. Product is also suited for protecting cables installed in areas at risk of shearing, including cabling next to helicopter rotor blades. Sleeving ranges in size from 0.02-0.6 in. and comes in various colors.
|
 DIN Adapters target infrastructure applications.RF Industries
San Diego, CA 92126 4202
Feb 28, 2006
Built to CECC-22190 international specifications, 7/16 DIN adapters are designed for transmission of medium to high power signals for base station applications. They have characteristic impedance of 50 ohms and electrical performance up to 7.5 Ghz. Available in various straight and right angle configurations, adapters feature brass male and beryllium copper female contacts, machined bodies, and Teflon® dielectric. Bodies and contacts are silver-plated.
|
 Emergency Lighting Station features glow-in-the-dark design.Pelican Products, Inc.
Torrance, CA 90505
Feb 28, 2006
Emergency Lighting Station, Model 2480 consists of clear polycarbonate case with photoluminescent decals, and MityLite(TM) 2440 LED flashlight with photoluminescent body that provides instant visibility in black-out situation. Five-LED array shines 21 lumens of light for up to 90 hours, while tail switch enables one-handed operation. Energizer® e2® Titanium Technology® batteries with 7-year shelf life are included.
|
 Ballast incorporates 5 input voltage taps.Universal Lighting Technologies
Nashville, TN 37214
Feb 28, 2006
Designed for 750 W pulse start systems, Multi-5® Model P750ML5AC5M is suited for use when retrofitting 1,000 W metal halide systems for energy savings. It includes 120, 208, 240, 277, and 480 V input voltage taps to cover all possible lighting voltage applications. Multi-5 technology minimizes inventory and eliminates need to know operating voltage in fixture prior to servicing or retrofitting it.
|
Security Network automates threat protection.CyberDefender Corp.
Los Angeles, CA 90025
Feb 28, 2006
Collaborative Internet Security Network(TM) is client-to-client relay network technology designed to protect CyberDefender-enabled PCs. It identifies unusual behavior, analyzes threats, and creates and distributes required definition files. Network rates threats on scale of 1-10, and threats rated 5 or above are recognized as viruses and virus alerts are sent. It provides defense against spyware, phishing, and viruses.
|
(Showing headlines 9421 - 9440) << 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669
|
|
|