Power Delivery System offers optional RF pulsing.Advanced Energy Industries Inc.
Fort Collins, CO 80525
Jul 19, 2007
Providing repeatability in complex applications, Paramount(TM) System allows accurate process control and uniformity when etching and depositing anti-reflective coatings, hard masks, cap layers, and etch-stop layers required by next-generation nodes. Measurement technology and optional ultra-fast frequency tuning enable system to deliver precise power at 13.56 MHz fixed or variable frequency.
|
Mini DC/DC Converters provide up to 300 V output.BEAR Power Supplies
Phelps, NY 14532
Jul 19, 2007
Operating from -55 to +85°C with no heat sink or electrical derating, BPS Series includes single-input, single-output isolated converters with input voltage from 3-15 Vdc and output voltage from 50-300 Vdc. Units offer typical efficiency of 90% and are suited for powering PIN diodes, avalanche photodiodes, and piezoelectric actuators. Housed in encapsulated package measuring 0.5 x 0.5 x 0.4 in., converters are available in through-hole and SMT versions.
|
 Vibration Limit Switch is designed for bulk solids industry.Pepperl + Fuchs, Inc.
Twinsburg, OH 44087 2245
Jul 18, 2007
Offering plug-and-play commissioning, Vibracon LVL-B Series has solid-state design that contributes to maintenance-free level sensing of fine or coarse-grained bulk solids materials. It requires no calibration and is insensitive to material build-up, external vibration, and flow noise. Each product features 10 in. vibrating rod, and extension pipes are available in 20, 40, and 60 in. sizes. Suited for hazardous environments, sensor is constructed of stainless steel.
|
 Spring Contact allows for solderless termination.RIA Connect
Tinton Falls, NJ 07112
Jul 18, 2007
Single pole, vibration-resistant Model ASM01Y allows connection of pinned components and individual solid wires ranging in size from 18-14 AWG, or stranded wires and ferrules. Device is THR compatible and can withstand soldering temperatures of 290° for 90 sec. Covering 3.5 mm², Model ASM01Y is suited for SMT applications and is available in tape and reel.
|
DC/DC Converter extends battery run time.Linear Technology Corp.
Milpitas, CA 95035
Jul 18, 2007
Housed in 2 x 3 mm DFN package, Model LTC3538 delivers regulated output voltage at up to 800 mA of continuous current with input voltage above, below, or equal to output. Input range of 2.4-5.5 V and output range of 1.5-5.25 makes unit suited for single-cell Li-Ion/Polymer applications. Delivering efficiencies up to 96%, synchronous, buck-boost converter provides constant 1 MHz switching frequency, ensuring low noise while minimizing external component size.
|
External Battery powers laptops and charges other devices.Tekkeon, Inc.
Tustin, CA 92780
Jul 18, 2007
While providing up to 4 hr of power for operating laptops, myPower(TM) ALL Plus MP3450 can simultaneously charge other small portable electronic devices through on-board USB port. Rechargeable lithium polymer universal battery comes with 9 adapter tips, retractable USB cable, and voltage selector switch for setting appropriate voltage for particular portable device. Automatic reset upon adapter change provides added safety to protect connected device.
|
 Rotating Power Strip leaves no wasted space.Quail Electronics
Livermore, CA 94550
Jul 18, 2007
Providing outlets on 180° axis, Rotating Power Strip is equipped with 6 rotating outlets and 2 fixed side outlets. It includes power push button, cord management design, EMI/RFI noise filter, surge protection, NEMA 5-15P rotating, NEMA 5-15R rotating, and 2,160 joules. Electrical rating is 15 A circuit breaker, 125 Vac, 60 Hz and 1,875 W.
|
 Raintight Fittings are available in steel and zinc.Bridgeport Fittings, Inc.
Stratford, CT 06497
Jul 17, 2007
UL-Listed EMT concrete-tight, raintight connectors feature split-type gland ring that prevents conduit from turning when tightening hex nut. Fittings enable user to connect PVC Jacketed cable by stripping back cable, unscrewing hex nut, and pushing in cable and tightening. They are available in ½-3½ in. steel, ½-2 in. zinc, and 12/2 to 8/3 for PVD Jacketed MC cable.
|
AC/DC Power Supplies can be PCB- or chassis-mounted.XP Power
Sunnyvale, CA 94085
Jul 17, 2007
Comprised of 10 W (ECL10) and 15 W (ECL15) versions, ECL series is available in open frame PCB-mount, encapsulated PCB-mount, and open frame chassis-mount formats. ECL10 measures 1.0 x 2.0 x 0.9 in., offering 5.6 W/in.³ power density. Both ECL10 and ECL15 offer single output voltages of 3.3, 5, 9, 12, 15, 24, and 48 Vdc. Full power is supplied across entire input voltage range of 85-264 Vac or 120-370 Vdc, and are suited for use in Class I and II isolation systems.
|
Single-Cell Boost Converter operates with less than 1.6 µA.austriamicrosystems AG
Premstatten Austria
Jul 17, 2007
Supplied in 5-pin TSOT23 package specified over -40 to +85°C range, AS1323 step-up dc/dc converter delivers 100 mA output current from single AA battery, with possible fixed output voltages of 2.7, 3.0, and 3.3 V operating from input voltage from 0.75-2 V. Integrated low-voltage boot circuit ensures start-up, even with high load currents. Minimum start-up voltage, 0.95 V, is independent of load current, and internal synchronous rectification eliminates need for external diode.
|
Motor Protection Relay offers multiple metering and relaying.Eaton Corp.
Cleveland, OH 44114
Jul 17, 2007
Conforming to UL 1053 ground fault protection standard, Cutler-Hammer® MP-4000 motor protection relay offers protection, fault diagnostics, power metering, and communication options such as Modbus RTU and Device Net. Voltage Transformer inputs enable protection functions and metering such as under/over voltage, negative sequence voltage, power factor, and frequency. Relay features Intel-I-Trip algorithm, voltage sag ride-through at 20 cycles, and motor start profile.
|
LED Driver suits mobile display and keypad LED backlighting.Sipex Corp.
Miliptas, CA 95035-1701
Jul 17, 2007
Available in 3 x 3 mm QFN16 package, Model SP7680 is targeted at backlighting main display, sub-display, and indicator functions. Seven LED driver channels are partitioned into 3 banks of 4 channels, 2 channels, and one channel, and each bank can be independently programmed through I2C interface up to 31 mA (63 mA for single channel bank) with 6-bit resolution. With -40 to +85°C operating temperature range, device operates at 2 MHz and utilizes 4 small capacitors.
|
 CAT 6 Protector targets network racks and I/O ports.Meter-Treater Inc.
Lake Park, FL 33403
Jul 16, 2007
Molded in high-impact ABS, Model CTI is fully CAT6 compliant and backward compatible for CAT5 and CAT5E applications. Unit provides bidirectional protection capability and meets channel limits in dB per ANSI/TIA/EIA-568B.2. With plug-and-play modularity, user removes patch cable from existing patch panel, snaps in CTI device, re-inserts cable, and makes ground connection.
|
Ferrules and Crimping Tools suit high volume applications.Panduit Corp.
Tinley Park, IL 60477 3091
Jul 16, 2007
Featuring continuously molded design for consistent placement in tools, REEL SMART(TM) Ferrules are available in No. 20-14 AWG in strips of 50 and reels of 3,000-5,000. Seamless barrel design contains loose wire strands. Semi-automatic CT-100 Crimping Tool features rapid load design utilizing strips of ferrules. Multi-use 54 lb tool cuts, strips, and crimps wire.
|
 Set-Point Flowswitches come in adjustable and fixed models.Orange Research, Inc.
Milford, CT 06460
Jul 13, 2007
Adjustable flowswitches come in fixed-orifice models for 0-2 to 0-40 gph (liquid)/1.5-5 scmf (gas) and variable-orifice models for 0-1 to 0-30 gpm/1.5-10 to 1-100 scfm. They incorporate adjustable, hermetically sealed reed switches and suit line pressures to 5,000 psig. Fixed set-point flowswitches, available with liquid flow settings in 6 steps from 0.1-1.5 gpm, have solid brass or stainless steel pistons and pressure bodies and stainless steel springs, enabling use up to 1,000 psig.
|
 Three-Phase Modular PDUs feature up to 42 outlets.Hewlett Packard
Houston, TX 77269-2000
Jul 13, 2007
With modular architecture that facilitates access to PDU outlets, HP 8.6 kVA and 11 kVA Power Distribution Units (PDUs) suit blade systems in dense data center environments. Each unit, which uses 3-phase input plug and has 6 IEC C19 outlets, consists of control unit and up to 6 optional extension bars. Control unit may be mounted in 1U/0U space, and extension bars mount directly to frame of rack in multiple locations. Extension bars have 7 outlets.
|
Portable USB Power Adapter charges range of devices.Tekkeon, Inc.
Tustin, CA 92780
Jul 13, 2007
Along with retractable prongs, retractable USB cable, and Mini USB adapter, myCharger(TM) package comes with several adapter tips for charging iPhone, iPod, and Blackberry devices as well as mobile phones by LG, Motorola, Nokia, Samsung, and Sony Ericsson. Optional adapter tips are available for other 5 V devices, including Bluetooth headsets, digital cameras, other mobile phones, MP3 players, PDAs, and portable media players. Optional travel pack includes international plugs.
|
Medical Power Supply offers variable wall mounted options.Transitronix
Ronkonkoma, NY 11779
Jul 13, 2007
Medical Wallmount power supplies are equipped standard with over current and short current protection. Unit is RoHS compliant and approved to medical UL60601. Features include 0 to +40°C full power operational temperature range and single output voltage options ranging from 3.3-24 Vdc. Power supplies are offered in 10, 15, 18, 30, and 40 W versions with US, UK, Euro, and Australian-type plug styles.
|
Light Source offers portable illumination for inspections.Lenox Instrument Co.
Trevose, PA 19053 3427
Jul 13, 2007
Adaptable to most fiber optic illuminated borescopes, fiberscopes, and videoscopes, cordless Model 3000LS-3.5LED operates on 3 C-cell batteries for 24 hours before new alkaline or rechargeable batteries are needed. Illumination is delivered by 5,000-6,000° Kelvin LED light, which produces up to 110,000 lux at input to light guide. Weighing 1.4 lb with batteries installed in 11 in. handle, light source offers shock and impact resistance.
|
 Exit Sign features self-testing diagnostics.Chloride Systems
Burgaw, NC 28425
Jul 12, 2007
Wet/damp location listed Tuff-Act operates from -40 to +113°F, and includes Intelli-Charge diagnostics to monitor all critical functions. Energy Star rated unit features high-brightness LEDs and provides 120 min emergency power with sealed NiCad battery. Available in AC Only and Self-Powered models, unit features aluminum housing with impact-resistant, injection-molded polycarbonate covers and vandal-resistant and anti-corrosion coated hardware.
|
(Showing headlines 7781 - 7800) << 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669
|
|
|