Controls & Controllers ->
Lighting Controls & Controllers
Lighting Controls & Controllers
(Showing headlines 1 - 20) more ....
|
 Lighting Control Panelboards utilize BACnet® protocol.Schneider Electric
Palatine, IL 60067-7399
Mar 19, 2008
Incorporating Building Automation and Control network communication protocol (BACnet®), Powerlink® lighting control systems can be seamlessly integrated into commercial building automation system. In addition to RS-485, Powerlink controllers can be connected directly to facility's LAN using 10BaseT Ethernet connection. This allows automation system's front-end software to communicate directly with each controller to monitor lighting status or perform user-initiated overrides.
|
 Room Controller enables LEED-certified lighting designs.Watt Stopper, Inc., The
Santa Clara, CA 95050
Oct 26, 2007
Suited for areas with small lighting control zones, Model LI-ARP provides 2 relay outputs to support bi-level switching and manual-on operation. It can also accept inputs from occupancy sensors and daylighting controls. By providing terminations for loads as well as for control inputs, LI-ARP eliminates multiple runs of line voltage and control wiring back to central panel location. Controller communicates with Lighting Integrator Complete Control System via single data line.
|
Lighting Control System suits fluorescent applications.IEPC Corp.
Huntington Beach, CA 92649
Sep 19, 2007
Combining solid-state electronics with on-site, remote, and aggregate Web-based controls, Vari-Ballast Control (VBC) includes electronic ballast and microprocessors to regulate current flow. Lamp and fixture maintenance is achieved by using built-in scheduler, timer, relay, and dimmer. Measuring 6 x 6 x 4 in., Model VB400 features 90-300 V universal input voltages, 14-430 W variable output wattages, and controlled start-up and shut-down.
|
HID Lighting Control enables web-based energy management.IEPC Corp.
Huntington Beach, CA 92649
Jun 06, 2007
Model VB400 lighting control system utilizes solid state electronics with on-site, remote, and aggregate Web-based controls for HID lighting. Designed for efficient energy management, system features electronic ballast, microprocessors for flow regulation, dimming and timing controls, automatic maintenance scheduler, and built-in photo cell for automatic daylight harvesting. System is compatible with all 200-400 W bulbs.
|
 Lighting Control offers efficient option for HID users.IEPC Corp.
Huntington Beach, CA 92649
May 31, 2007
Featuring solid-state electronics, Model VB400 enables automatic, manual, and remote control to provide HID lighting that is energy efficient and can be integrated into demand-response scenario. It replaces magnetic ballasts, timers, relays, control panels, photo cells, and intensive wiring required to connect each fixture to all external parts. Featuring plug-and-play design, Model VB400 enables use of 200-400 W bulbs no matter what manufacturer, HID type, or input voltage.
|
Self-Powered Switch wirelessly controls building lights.Ad Hoc Electronics
Orem, UT 84058
Mar 28, 2007
Offering alternative to wired solutions when installing lighting control into existing buildings, Ad Hoc wireless lighting control systems consist of transmitters (switches) and receivers that are wired between light and power-source. One switch can be configured to control unlimited number of lights and generates its own electricity using EnOcean's energy-harvesting technology.
|
 Relays target automotive and lamp accessories.CIT Relay & Switch: Division of Circuit Interruption Technology, Inc.
Maple Grove, MN 55369
Nov 03, 2006
Offering PCB pin and quick-connect mounting, A2 Series features contact ratings up to 40 A at 14 Vdc, while A3 Series is rated 80 A at 14 Vdc. Contact resistance is less than 30 mW initially on both types. Max switching power, voltage, and current is 630 W, 75 Vdc, and 40 A for A2 Series and 1,120 W, 75 Vdc, and 80 A for A3 Series. Providing electrical life of 100K cycles, units are solderable at 260°C for 5 sec with operating temperature of -40 to 85°C.
|
Device provides daylight management control for 2 rooms.Leviton Manufacturing Co., Inc.
Little Neck, NY 11362 2591
Oct 04, 2006
Combining occupancy sensing, daylight harvesting, and flexible lighting control in single package, Dual Room miniZ(TM) meets variety of commercial lighting needs. Self-contained, self-configuring system takes into account changing environmental conditions, and meets energy-code mandates for balancing artificial and natural light sources. AutoCal(TM) feature automates photocell calibration, establishing max light output levels and calculating light loss factors.
|
Control Systems regulate scheduling and energy use.Triangle Micro Systems, Inc.
Raleigh, NC 27616
Aug 25, 2006
Designed for convenience stores, BASYX CS system can control time of day scheduling, temperature, and humidity, as well as electrical usage. BASYX CW system, designed for free-standing car wash systems, controls fans and heating stages to maintain proper temperatures and automatically adjust bay setpoints based on outdoor temperatures. In addition to programmable outputs that control interior and exterior lighting, both systems offer remote access and notification capabilities.
|
Controller/Software simplifies complex lighting control.Vantage Controls, Inc.
Orem, UT 84097
May 01, 2006
Allowing for more than 100 available stations, InFusion Controller includes processor, memory, built-in Ethernet jack, and USB port. Infusion Design Center software accompanying controller provides 3rd party device libraries with drag-and-drop menus, facilitating integration of audio video solutions. Program also features savable and reusable customized programming.
|
Tablet Touch Screen controls lights, security systems, etc.Vantage Controls, Inc.
Orem, UT 84097
Apr 28, 2006
Using wireless communication, TouchPoint 1210 provides definitive control of lights, heating and cooling, fireplaces, distributed audio systems, video equipment, home theaters, and window treatments. It offers in-wall, desktop, VESA mount, kickstand, and under-counter mounting possibilities. Included InFusion Media 1.0 software allows utilization of custom designed interface developed in InFusion Design Center. TouchPoint 1210 is available in white, silver, and black.
|
 Databus System monitors status of motors and lighting.Cole Hersee Co.
Boston, MA 02127 2467
Mar 15, 2006
Suited for crane, vehicle, and utility applications, self-contained MiniBus(TM) digital multiplex system is specifically designed for switching high-amp dc motors and operation of lighting on vehicles. It minimizes wiring as units are linked by single electrical cable. If needed, multiple loads can be added to system.
|
 Lighting Control Panel complies with energy codes.Watt Stopper, Inc., The
Santa Clara, CA 95050
Dec 30, 2005
Lighting Integrator is available with BACnet option, which enables native level integration of lighting control with BACnet-based building automation system. Option also ensures lighting control compliance with energy codes such as ASHRAE 90.1 and IECC while eliminating need for BAS to support lighting-specific functions. With BACnet, users still have convenience of control options such as blink warnings and wall switch overrides with time delays.
|
Lighting Contactor is designed for branch circuits.Rockwell Automation
Milwaukee, WI 53204
Aug 02, 2005
Requiring momentary 20 A applied current to open or close, multi-pole Bulletin 500LC is controllable from multiple sources. Contactor connects with various control systems and devices and can have 2-wire, 3-wire, and start/stop control to allow it to interface with remote objects. With small footprint and four screw mount, unit installs within, or next to, enclosures and is UL 508 listed, CSA certified, and suited for UL 67 listed panelboards.
|
 Lighting Controller suits machine vision applications.Deva Electronic Controls Ltd
Wirral CH41 1EL United Kingdom
Jun 11, 2004 Controlled and powered via single USB connection, Deva 022 incorporates 64 LED light ring and 2 auxiliary outputs. Individual control of LED intensity and radial position allows user to direct light onto subject from any angle. Auxiliary outputs are connected via 2.5 mm dc jack sockets and provide intensity control up to 12 x 4 LEDS. Plug and play device is supplied with drivers compatible with Windows 98/2000/XP/ME. |
 Lighting Control offers bi-level switching of HID fixtures.Watt Stopper, Inc., The
Santa Clara, CA 95050
May 17, 2004 Model DM-105-WP features low voltage outdoor motion sensor, which uses passive infrared technology to detect occupancy. During times of vacancy, controller switches lights to lower level. When occupants return, lights immediately return to high. Bi-level switching capability eliminates long restrike time associated with ON/OFF control of HID lighting. Rated for outdoor use, sensor and controller handle wet locations and fluctuating temperatures. |
 Power Pack offers switching and dimming of lighting loads.Watt Stopper, Inc., The
Santa Clara, CA 95050
May 13, 2004 Intelligent Power Pack Model LC-100 features 2 relay outputs and dimming channels for up to 100 ballasts per channel. It contains inputs for connecting occupancy sensors, photosensors, building automation systems, and relay-based lighting control panels, enabling dimming, daylighting, load shedding, and blink warnings for 2 separate lighting loads simultaneously. Unit operates at 120 or 277 Vac and installs as standard power pack. |
 LED Controller suits machine vision applications.Schott-Fostec, LLC
Auburn, NY 13021 3120
Aug 05, 2003 Pro Ultra LED Controller consists of one regulated constant current with variable intensity controller. Product recognizes connected LED light head and requires no adjustments when changing heads. Trigger function extends LED head lifetime and provides dark periods during part inspection. Offerings include automatic over temperature protection, overdrive intensity mode, grounded metal industrial housing, and single-knob light intensity control (0–150%). |
Lighting Control System manages public lighting.GE Company, GE Lighting
Cleveland, OH 44112
May 01, 2003 Pro-Tec 3000 offers wide range of management and monitoring capabilities, enabling measurements such as number and timing of faults detected, current value at time of fault, and cause of fault. Lighting operators can reduce diameter of cable required, and increase distances between relays. Repair requirements can be pinpointed rapidly, reducing downtime and improving public safety. |
 Lighting Controller does not require hard wiring to fixtures.Sportlite Inc.
Glendale, AZ 85301
Mar 17, 2003 Advanced Lighting System with PulseBloc® utilizes digital pulse technology to provide 4 levels of remote stepped dimming. System consists of 3 components: Sportlite fixture, PulseBloc receiver, and PulseBloc wall controller. PulseBloc digital pulse technology is unaffected by noise on line, allowing signals to get through 99.97% reliability. Using existing wiring as communication medium, system does not interfere with other equipment in building. |
(Showing headlines 1 - 20) more ....
|
|
|