|
|
|
Controls & Controllers ->
Fluid & Gas Controls & Controllers ->
Level Controls & Controllers
Level Controls & Controllers
(Showing headlines 1 - 20) more ....
|
 Sump Level Regulator can be used for all fluid types.Zebra Skimmers Corp
Solon, OH 44139
Mar 09, 2009
Featuring heavy duty, mechanical components, Sump Level Regulator (SLR) activates user's water supply or fluid pump to maintain correct fluid operating level in each machine tool sump or central tank. It has only two moving parts, and offers simple, two-step installation. When coupled with Fill-Station(TM), unit creates automated fluid on demand system.
|
 Level Controller utilizes non-contacting ultrasonic sensor.Greyline Instruments, Inc.
Massena, NY 13662
Feb 06, 2009
Designed for sewage lift stations, wet wells, and storage tanks, PSL Pump Station Level Controller features isolated 4-20 mA output and 6 programmable control relays for pump control, pump alternation, and level alarms. Automatic pump run time logging and reporting system helps operators to plan pump maintenance. Each PSL includes PSL Remote for Windows(TM) Operators software, which can prepare and save calibrations in advance and download to PSL through password-protected RS232 interface.
|
Point Level Switch offers SIL-certified overfill protection.AMETEK Drexelbrook
Horsham, PA 19044
Feb 04, 2009
Safety IntelliPoint RF(TM) Switch, used in above-ground bulk storage tanks, meets American Petroleum Institute's 2350 Recommended Practice for overfill/spill protection. Specifically, it comes standard with SIL1 certification; SIL2 is optional, and SIL3 is possible with redundant switch. Integral software continuously monitors application for changes and maintains repeatable trip point on probe. Switch detects presence or absence of material without calibration, and MTTF is 110 years.
|
Ultrasonic Level Controller works from up to 26 ft away.Omega Engineering, Inc.
Stamford, CT 06907
May 02, 2008
Model LVCN700 Series of non-contact controllers provide fail-safe intelligence with diagnostic feedback for troubleshooting. Pushbutton target calibration features 3-relay outputs that can be configured on single set-point alarm and 3 in. beam diameter for restricted space applications. Protected by PC/ABS NEMA 4X rated enclosure, units are designed for range of corrosive, waste, and slurry-type media, and waste sump applications.
|
 Ultrasonic Level Controller is CE compliant.Omega Engineering, Inc.
Stamford, CT 06907
Apr 18, 2008
Designed for continuous and switching operations, LVCN414 Series non-contact level controller offers output of 4-20 mA to drive any local display or PLC to monitor process level, control, or chemical feed applications. Unit is configured through USB connection and Windows XP compatible software calibration kit. It can be used with water, waste water, chemical tanks, and fuel tanks in chemical, automotive, water, and petroleum industries.
|
 Lift Station Control provides open channel flow monitoring.Siemens Energy & Automation, Inc.
Alpharetta, GA 30005
Oct 17, 2007
Designed for duplex lift stations in water and wastewater plants, Sitrans LUC500 Level Controller combines non-contacting ultrasonic technology, echo-processing techniques, and application software to provide level control of liquids in wet wells up to 50 ft deep. Unit also monitors flow in flumes, weirs, and other open channels. Providing 16 digital inputs and 5 relays, LUC500 features fault monitoring and data logging, as well as integration with SCADA, PLC, or DCS systems.
|
 Level Compensator suits high automation material handling.PIAB Vacuum Products
Hingham, MA 02043
Oct 24, 2006
Designed to adjust level differences in lifting devices that are fitted with several suction cups, Model LC30 minimizes demand for exact vertical positioning. Conical stainless steel spring rests in cushion of polyurethane that optimizes damping. Featuring 1.18 in. stroke and max vertical load of 157 lbf, unit can be adjusted by 0.47 in., and can also be made non-rotational. Compensator may be integrated into any PIAB vacuum product.
|
 Level Sensor tracks inventory in smaller tanks and silos.BinMaster
Lincoln, NE 68529
Oct 18, 2006
Used in vessels as deep as 30 ft, SmartBob-TS1 can be used to start or stop machinery instantly when product reaches specified level or show whether product is flowing freely. It is unaffected by airborne dust, filling noise, steam, temperature, or measured material's characteristics. When dropped to material surface level, sensor immediately retracts to ensure minimal contact; verifying measurement is taken during ascent.
|
 Bin Picking System requires one light grid per bin.SICK, Inc.
Minneapolis, MN 55438
Jun 23, 2006
Suited for assembly and picking applications, Pick2Light bin control system offers hand detection and 360°-viewable job LED. Single-sided, retro-reflective light grid features t-slot frame mounting feature. Without restricting bin size, external mounting configuration minimizes damage caused by workers when removing parts or inserting bins. Features include metal housing, 2 m max range, and 5 available sensor heights from 120-420 mm.
|
 Radar Interface Board has dual-channel architecture.Curtiss-Wright Controls Embedded Computing
San Diego, CA 92121-1773
Jun 16, 2006
Available in PMC mezzanine card or half-length PCI card formats, Osiris supports 2 independent radar channels inputs at rates to 16k samples/return. Open standard-based solution supports sampling at frequencies up to 50 MHz on each of its 2 analog inputs, which can be mixed with up to 8 digital radar inputs. Its 64 bit, 66 MHz PCI interface can output 2 streams of radar video directly to host processor, and each stream can be processed using one of 2 sets of trigger and turning data.
|
 Multi-Controller facilitates dry product measurement.Emerson Process Management
Austin, TX 78754
Nov 29, 2005
Designed for Mobrey ULT ultrasonic level transmitters or any HART-enabled field device, SCU Multi-Controller enables operator to program and view real-time readings from up to 15 transmitters from central control room. It is compatible with HART-compliant 2-wire and 4-wire units and has integrated LCD panel for variety of display functions. Output options include 4-20 mA and relays, which are programmed via 6-button keypad housed in IP65 enclosure.
|
 Tuning Fork Switch offers high and low level indication.AMETEK Drexelbrook
Horsham, PA 19044
May 25, 2005 Series TF-100 provides no-calibration solution to point level measurement of clean liquids and is available with relay, current, or PNP outputs. Made of 316 stainless steel, sensor is offered in standard and sanitary versions. When material level reaches predetermined point on sensing element, it causes change in status in electronic unit, resulting in output that can operate alarms, annunciators, valves, or other controls or indicators. |
 Ultrasonic Monitor determines depth of sludge blanket.Clark-Reliance Corp., The
Strongsville, OH 44136
Apr 15, 2005 Utilizing sonar principle, MS600 analyzes pulse of ultrasound that transmits vertically and reflects from surface of sludge blanket. Menu-driven program enables complete configuration of unit, while local programming is carried out via membrane keypad. Optimized for use with clarifier and thickeners containing municipal and industrial wastewater treatment sludge, system is comprised of self-cleaning ultrasonic transducer and bridge-mounted control unit. |
 Boiler Cut-Out Device offers upgrade kit.Clark-Reliance Corp., The
Strongsville, OH 44136
Apr 04, 2005 Series EA-100 Levalarm with upgrade kit replaces original float mechanism and micro switch with conductivity probe and detection relay, eliminating all moving parts. Relay provides 2 independent dry Form C switch contacts. Kit requires no welding, re-work of piping, or adjustments, and takes minutes to install. |
 Point Level Control features no-moving-part design.Princo Instruments, Inc.
Southampton, PA 18966
Mar 22, 2005 Null-Kote⢠L2000-OEM employs circuitry to cancel out any effects of coatings or material build-up on sensing probe. It includes 10 A relay, explosionproof/weatherproof NEMA 4 housing, 0ā30 sec time delay, and high or low fail safe, as well as 316 stainless steel and Teflon® sensing probe with temperature range of -300 to 500°F. Rollock⢠probe design ensures that no part of sensor can fall into process or be blown from mounting. |
 Water Control System suits wetland conservation.Hancor, Inc.
Findlay, OH 45839
Nov 30, 2004 Watertight Water Control Structure offers timely, precise water control to improve water quality. It reduces contaminants, provides flood control, assists with erosion control, and provides habitat and food source for wildlife. System retains exact targeted water amounts with water levels that are adjustable in 1 in. increments. HDPE body and stainless steel components are compatible with variety of pipe materials. |
 Controller alerts personnel of low chemical levels.Dosatron International Inc.
Clearwater, FL 33765 1201
Mar 19, 2004 Low Level Controller offers protection from chemical outages that could damage equipment or finished goods in metal processing applications. Splash-resistant control box includes built-in audible and visual alarm to indicate when fluid in tank drops below specific level. Tank float is comprised of CPVC chemical-resistant components, 2 in. standard bung cap, and stem that can be cut to fit tank size. Controller can be integrated into dispensing system. |
Switch combines temperature and level control.Norgren
Littleton, CO 80120
Dec 03, 2003 Temperature/Level Switch is available with variety of switching configurations and temperature settings. Floats are provided as normally open on stems, but can be reversed to normally closed when specified. Switch wiring and installation is through one opening. Suitable for water and hydrocarbons, switch has max operating pressure of 150 psi. Operating temperatures are from -40 to +225°F in oil and -40 to +180°F in water. |
 Control measures solid and liquid levels.KSR Kuebler Of America, Inc.
Raleigh, NC 27613
Sep 26, 2003 Wave Control 234 harnesses ultrasonic band pressure waves to provide non-contact measurement of solid and liquid levels within tanks. Low frequency operation resists distortion and energy absorption from foam, dust, wind, and condensation. Available in 2-, 3- and 4-wire configurations, system utilizes transducer, which directs energy toward tank material. Standard range of 2-wire model is 80 m with overall accuracy of ±.25%. |
 Level Controller accepts all standard input signals.Sigma Controls Inc.
Perkasie, PA 18944 1335
Sep 25, 2003 Programmable MYRIAD LC1 Digital Level Controller is microprocessor-based and housed in NEMA 4, watertight, outdoor enclosure. PC board is removable and graphical backlit display provides digital and bar graph level readouts with user-selectable engineering units. Four solid state digital inputs, 4 solid state outputs, and 2 form C relay outputs with setpoint and dead band adjustments are provided. |
(Showing headlines 1 - 20) more ....
|
|
|
|
 |
ThomasNet News Advertisers
|
 |
|