Advertisement
|
|
Controls & Controllers ->
Fluid & Gas Controls & Controllers
Fluid & Gas Controls & Controllers
(Showing headlines 161 - 180) 1 2 3 4 5 6 7 8 9 10 11 12
|
 Transmitters/Controllers offer on-line calibration adjustments.Barton Instrument Systems, LLC
City Of Industry, CA 91749-1882
Feb 24, 2003 Series B30 Transmitters and B40 Transmitters-Controllers provide measurement and control of differential pressure, absolute pressure, gauge pressure, and saturated steam flow. Non-conductive and conductive liquids at high viscosities can be accommodated. Units feature remote options, rotatable NEMA 4X/6P housing and rotatable smart display, and built-in PID controller. They have Hastelloy-C diaphragms, 316SS wetted parts, and ¼ or ½ in. NPTF process connections. |
 Pressure Regulator is a zero leak device.Airtrol Components Inc.
New Berlin, WI 53146 2107
Feb 24, 2003 Unit regulates pneumatic or water pressures in applications that require little or no flow. Output is adjustable with ranges from 0-3.5 psi to 0-100 psi with 15 turns of resolution. Maximum supply pressure is 150 psi with maximum air flow of 1.0 scfm, and maximum water flow of 0.2 gpm. Non-bleed, non-relieving type regulator is for use in medical equipment, air bearings, and custom machinery. Parts can be flush or panel mounted. |
Pump Controller manages performance in various conditions.Bell & Gossett
Morton Grove, IL 60053
Feb 24, 2003 Technovar® Pump Controller consists of variable frequency drive with integral microprocessor controller that mounts directly on motor. Utilizing variable speed capability, controller adjusts power consumption. Programmable features include over/under voltage protection, overload/overhead protection, and adjustable acceleration/deceleration. Available in 1–30 hp, product allows for staging and sequencing of up to 4 pumps and performs 4 system control methods. |
 Solenoid Control Module has step-down power control circuit.Bio-Chem Valve Inc.
Boonton, NJ 07005
Feb 19, 2003 CoolCube™ allows placement of overdrive voltage on solenoid valve, which can decrease valve response time, increase operating pressure, and reduce power consumption. Control module provides step-down voltage to 1/3 of input voltage. Hit and hold circuit accepts 12 or 24 Vdc input to energize solenoid valve with full power for 110 msec. It then drops voltage and current and reduces power consumption to 1/9 of original value to hold valve in its energized mode, reducing heat generation. |
 Flowmeters/Controllers feature max flowrate of 100 L/min.Aalborg Instruments & Controls, Inc.
Orangeburg, NY 10962
Feb 13, 2003 CE compliant, AF Thermal Mass Flowmeters and Controllers use straight tube sensors to ensure laminar gas flow. Materials in contact with gases are stainless steel and Viton™ O-rings. PC boards have built-in polarity reversal protection, and resettable fuses provide power input protection. Response time is typically 1 sec to within ±2% of flow setting. Units provide 0–5 Vdc output and ±1% full scale accuracy. Maximum gas pressure is 500 psig. |
 Flow Controller suits tight areas and mobile units.Pneucleus Technologies LLC
Hollis, NH 03049
Feb 03, 2003 MicroFlo miniature mass flow controller features InSitu-Sense™ sensing technology, which incorporates microchip-sized, in-line flow transducer to achieve repeatable and stable flow regulation in 40 msec. It is specifically for gases used in chromatography, elemental analyzers, gas detectors, gas monitoring, and vacuum coating applications. |
 Controllers work with heat pumps and air conditioners.EDC International, Inc.
Shelton, CT 06484
Jan 23, 2003 Head Pressure Controllers sense refrigerant temperatures and modulate condenser fan speed to balance high to low side circuit vapor pressure. On start up, fan is given initial hard start at full speed for 10 seconds and then slows to speed to give required condensing temperature. As ambient temperatures fall further, fan gradually slows to about 1/3 full speed to maintain bearing lubrication and can be re-set to any desired level. |
 Liquid Level Control suits low level cutoff protection.ABB SSAC
Baldwinsville, NY 13027
Jan 22, 2003 Single probe LLC8 series uses AC current sensing to prevent thermal runaway and excessively high internal pressure in hot water tanks by detecting presence of conductive liquids. With open board design and UL353 recognition, it offers factory fixed time delay of 1–60 sec and is available for input voltages of 24, 120, or 230 Vac, 50/60 Hz. Sense resistance is factory fixed from 5K–250K ohms. SPDT relay contacts are rated 10 A resistive at 120/240 Vac. |
 Mass Flow Controller offers ±1% full-scale accuracy.Aalborg Instruments & Controls, Inc.
Orangeburg, NY 10962
Jan 10, 2003 Digital Flow Controller allows user to program, record, analyze, and control flow rates of various gases with computer via RS-485 interface. Auto zero feature utilizes automatic balancing circuit that virtually eliminates drift of zero and span. On-board memory enables each controller to store NIST-traceable calibrations for up to 10 gases. Maximum flow is 100 sL/min and max gas pressure is 500 psig. Output signals include 4–20 mA, 0–5 Vdc, and 0–10 Vdc. |
 Pressure Controller/Calibrator provides accuracy to 0.005%.Ruska Instrument Corp., A Druck Co.
Houston, TX 77042
Dec 20, 2002 Digital Series 7250 incorporates quartz sensor, RS-232 and IEEE-488 interfaces, and active-matrix, full color screen with 6.4 in. diagonal viewing area. User-selectable control modes include Active and Passive mode. Former continuously controls set-point and corrects for leaks and temperature effects, while latter permits user to define upper and lower limit. Series includes 3 models with pressure ranges from 0–5 to 0–1,000 psi through 0–20 to 0–2,500 psi. |
 Liquid and Gas Controllers provide accuracy to ±3% FS.Key Instruments
Trevose, PA 19053-3428
Dec 20, 2002 Series 8500 Optaflow® Controller combines noncontact optical sensors and electromechanical features to set and monitor flow control functions. Tracking mode adjusts unit's control valve to maintain preset flow parameters and integrated alarm provides audible and visual signal. Units include remote PC interface via RS 232/485. Liquid models are calibrated for water and contain 1 manual bleed valve. Gas models offers selectable calibration of 6 gases. |
 Fluid Management System suits oil change centers.Graco Inc.
Minneapolis, MN 55440
Dec 11, 2002 Matrix™ Total Fluid Management System™ provides wireless metering, tracking, and delivery of oil, gear lube, anti-freeze, and transmission fluids. System tracks all fluids dispensed through Matrix system, and records transactions and inventory levels. Multi-level security and PIN codes protect system and assets. Electronic meters dispense fluids in pints, quarts, gallons, or liters, and tank level monitors keep track of bulk fluids in storage tanks. |
 Flow Controller operates in header systems.Kates, W.A., Co., A Taube Co.
Clawson, MI 48017
Dec 03, 2002 Flo-Miser controls flow rates to within 1½ % of setting, regardless of fluctuations in upstream or downstream pressures. Applications include chemical, petrochemical, paper, automotive, pharmaceutical, food and beverage, textiles, and plastics industries. |
 Flow Controls have expanded internal o-ring.Parker Hannifin Corp., Pneumatic Div.
Richland, MI 49083 0901
Dec 01, 2002
Banjo-style Miniature Flow Control mounts directly on small-bore cylinders such as those used in micro-pneumatic applications. Unidirectional valve has adjustment screw that produces linear flow and allows free flow of intake air while metering exhaust air. Available with or without knob adjuster, flow control is offered with 10-32 UNF to 1/2 in. NPT threads for 5/32 to 1/2 in. tubing or up to 1/2 in. female threads.
|
 Pressure Regulator suits various instrument applications.U.S. Para Plate Corporation
Auburn, CA 95602
Nov 14, 2002 Miniature 9028 series cartridge style regulator uses all available sensing area to provide precision set pressure control in limited-space installations. Design accommodates inlet pressures to 750 psi, while outlet is factory preset for pressures from 2 to 10 psi. Cartridge can be used in single cavity or manifold. Valve spring housing projects above manifold top surface by less than 0.5 in. Materials of construction are 316 SST, brass, or aluminum. |
 Controllers provide multi-function capabilities.McDonnell & Miller
Chicago, IL 60618 5523
Nov 11, 2002 Conductance actuated level devices control burner circuits, pumps, motor starters, and electric valves. Dual-function 750B-LP-120 models have low-water cutoff and pump control capabilities, while 750B-DLP-120 models have tri-function capabilities, with 2 low-water cutoffs and pump control. Both controllers are available in panel mount configurations and are CSD-1 compliant. Series 750B controllers provide low-water cutoff protection and level control. |
 Rotary Level Control senses level of dry solids.Garner Industries
Lincoln, NE 68504
Nov 11, 2002 Mini-Rotary has few moving parts and is designed for use in small bins, hoppers, and feeders. Slow-speed synchronous motor rotates paddle that senses pressure of material at level where unit is placed. Sensitivity can be adjusted allowing unit to be used in both light and heavy materials. Small design allows use in areas where other level sensors will not fit. |
 Sludge Level Control can monitor thin floc levels.Markland Specialty Engineering Ltd.
Rexdale, ON M9W 4M2 Canada
Nov 07, 2002 Sludge Blanket Level Control uses laser-like beam to monitor thin floc and Dissolved Air Flotation sludge levels. Microprocessor-based instrument is housed in NEMA 4X enclosure with LCD local readout, 4-20 mA output, 2 set-point relays, and RS 232/485 serial port. Self-diagnostic system simplifies debugging. Depth ranges are 4 or 8 ft. Fixed installation and portable models are available. |
 Mass Flow Controller handles flow rates for multiple gases.Sierra Instruments, Inc.
Monterey, CA 93940
Nov 06, 2002 With stainless steel construction, digital Smart-Trak™ is available in any range from 0–10 sccm to 0–50 slm. Dial-A-Gas™ feature and pilot module interface allow changing gases and critical parameters in field. Microprocessor is programmed for 10 gases used in biotech, pharmaceutical, analytical, and research applications. Other gases may be specified for custom unit. Device has RS232 output and 2 user-selectable analog outputs. |
 Gas Ignition Controls can continuously monitor functions.Fenwal
Ashland, MA 01721
Nov 01, 2002 Custom Gas Ignition Controls integrate previously discrete functions such as gas control and temperature sensing, with field-adjustable fan off delay into one unit with one central wiring point. Available with over 1,000 variations of spark electrodes and flame sense rods, controls are microprocessor-controlled and can provide ignition timing from a few seconds to several hours, with 0.2 sec accuracy. Packaging options include PC boards and range of enclosures and connectors. |
(Showing headlines 161 - 180) 1 2 3 4 5 6 7 8 9 10 11 12
|
|
|