|
|
|
Chemicals & Chemical Processing ->
Sampling Devices ->
Other
Other
(Showing headlines 21 - 32) 1 2
|
 Diluter/Dispenser facilitates sample preparation process.Valco Instrument Co., Inc.
Houston, TX 77255
Jan 30, 2006
Built around syringe-free, bi-directional, positive displacement pump, Cheminert M Series includes Model M10 with flow range of 10 nl to 10 ml and Model M50 with range of 50 µl to 50 ml. Wizard format eliminates math calculations and external charts. Users enter dilution ratio and final volume, and correct volume is calculated and automatically dispensed. Multiposition stream selection valve can be integrated with pump for multi-solvent applications.
|
Sample Preparation System facilitates molecular testing.Beckman Coulter, Inc.
Fullerton, CA 92834-3100
Jan 05, 2006
Based on Biomek® automation and diagnostic primary tube handling technologies, Vidiera(TM) NsP Nucleic Sample Preparation platform provides nucleic acid isolation, quantification, normalization, and reaction set-up for downstream assay analysis. Suited for molecular diagnostic applications in virology and pathology, Vidiera NsP enables hospital and reference labs to centralize pre-analytical functions in one room and streamline process.
|
 Gas Dryers handle flows up to 1 lpm.Perma Pure Inc.
Toms River, NJ 08754
Nov 08, 2005
Designed to dry hot, wet, sample gases prior to analysis, MDH(TM) Series combines heating element with Nafion® technology, which selectively removes only water from sample gases, leaving rest of gas sample unaffected. Dryers remove water directly from vapor phase, preventing loss of water-soluble gases through dissolution in condensate. Units can dry gases with as much as 30% water by volume and use built-in thermostat to prevent condensation throughout drying process.
|
 Micro Sample Preparation Tools deliver precision cutting.JASCO, Inc.
Easton, MD 21601
Oct 18, 2005
SliceMaster HS-1 Vertical Slicer is capable of cutting various materials in thin sections from 100-600 µm, depending on material, with variable thickness selection. Capable of cutting samples at 15° angle, HK-1 Angled Slicer handles thicknesses from 60-140 µm. Model HW-1 Multi-angle Slicer, capable of cutting samples at any angle from 45-90°, allows user to view slicing process of samples with microscope. It provides thin sections from 10-500 µm.
|
 Dry Bath controls temperatures from -10 to +100°C.Torrey Pines Scientific, Inc.
San Marcos, CA 92069
Jan 03, 2005 EchoTherm™ Model IC20 can freeze, chill, or heat samples in assay plates, centrifuge tubes, vials, and test tubes. Peltier driven unit measures 6.5 x 8.75 x 3.5 in. and comes with chiller/heater module, UPS, and ac line cord. It provides digital display and control of temperature to 1°C; count down timer in days, hours, minutes and seconds to 30 days; data logger; and RS232 interface. Product is suited for various uses in molecular biology labs. |
Analytic Extractor suits bioanalytical sample preparation.Argonaut Technologies
Redwood City, CA 94063
Nov 17, 2004 EVOLUTE ABN (Acidic Basic Neutral) provides means to extract drugs from biological fluids through solid phase extraction (SPE). Able to process plasma extracts and quantify drug concentrations using LC-MS/MS analysis, product reduces problems of ion suppression and matrix effects. EVOLUTE ABN SPE columns and 96-well plates use polymer-based sorbent to facilitate separation of unneeded matrix materials from analytes. |
 Sample Preparation System suits range of polymer types.Polymer Laboratories, Inc.
Amherst, MA 01002
Oct 01, 2004 Intended for manual dissolution and filtration of samples prior to GPC analysis, Model PL-SP 260VS combines controlled heating across temperature range of 30–260°C with gentle agitation and user-selectable speeds between 85–230 rpm. Pipettor device dispenses hot filtered sample solution from preparation vial directly into destination vials, with minimal handling. Choice of filtration media includes 1µm glass fiber and porous stainless steel.
|
 Gas Sampling System is probe mounted.Perma Pure Inc.
Toms River, NJ 08754
Jul 22, 2004 Designed to prepare wet, hot, and dirty stack gases for analysis, 1640 Mini-GASS (Gas Analysis Sampling System) allows users to accurately monitor smoke stack emissions. Gas conditioning system extracts sample gas via integrated sample probe and passes it through series of filters, scrubbers, and dryers. Housed in stainless steel cabinet, components remove water, acid mist, and ash without altering concentrations of gases to be analyzed. |
 Sample Conditioning Modules provide single-point sampling.Waters Equipment Co.
Lansdale, PA 19446 0576
Jul 14, 2003 Series 3100 provides tool for lowering temperature and pressure of single samples in power plants and boiler rooms. Units handle sample conditions up to 5,000 psig at 1,000°F. Sample flows up to 1,500 cc/min and beyond are capable of being cooled to within degrees of cooling water temperature due to high-efficiency coolers. Carbon-steel or optional stainless-steel backplate allows for mounting to plant's control panel or suitable structure. |
 Sample Cutter handles soft, moist foods and materials.Bel-Art Products
Pequannock, NJ 07440 1920
Apr 23, 2003
Molded of polycarbonate, Scienceware® Sample Cutter is a three tined fork constructed with sharp rocker knife on its back edge. Product has sturdy handle for positive grip when manipulating tough samples. Cutter, measuring 7.5 in. long, can be safely autoclaved at 250°F or cleaned using commercial dishwasher.
|
 Automatic Drawdown Machine is suited for laboratory use.Paul N. Gardner Co., Inc.
Pompano Beach, FL 33060 6608
Oct 29, 2002
AUTO-DRAW(TM) III motorized laboratory drawdown machine eliminates human variables to create laboratory precision samples. Able to control speed and direction, unit produces samples up to 8˝ x 13 in. at 47 in./minute rate. Machine offers 1-switch control knob.
|
 Disrupter Press disintegrates cells.Thermo Spectronic
Rochester, NY 14625
Apr 23, 2002 Enhancements to FRENCH(R) Press include startup kits and valves. Start Up Kit and Miniature 20K Start Up Kit both include motor driven Laboratory Press, spare parts kit, and cell filling stand. Valves include Press Flow Valve and Press O-ring Stem Valve, both for Standard 40K pressure cell. Press and pressure cells are used for disintegration of chloroplast materials, blood cells, unicellular organisms, and other biological particles.
|
(Showing headlines 21 - 32) 1 2
|
|
|