Quantcast
 
Search for: Search what?
Nov 25, 2009  
 Sections
Latest New Product News
Industry Market Trends
Green & Clean News
Association & Government News
Adhesives and Sealants
Agricultural and Farming Products
Architectural and Civil Engineering Products
Automatic ID
Chemical Processing and Waste Management
Cleaning Products and Equipment
Communication Systems and Equipment
Computer Hardware and Peripherals
Construction Equipment and Supplies
Controls and Controllers
Display and Presentation Equipment
Electrical Equipment and Systems
Electronic Components and Devices
Explosives, Armaments and Weaponry
Fasteners and Hardware
Fluid and Gas Flow Equipment
Food Processing and Preparation
Health, Medical and Dental Supplies and Equipment
HVAC
Labels, Tags, Signage and Equipment
Laboratory and Research Supplies and Equipment
Lubricants
Machinery and Machining Tools
Material Handling and Storage
Materials and Material Processing
Mechanical Components and Assemblies
Mechanical Power Transmission
Mining, Oil Drilling & Refining
Mounting and Attaching Products
Non-Industrial Products
Optics and Photonics
Packaging Products & Equipment
Paints and Coatings
Plant Furnishings and Accessories
Portable Tools
Printing and Duplicating Equipment
Retail and Sales Equipment
Robotics
Safety and Security Equipment
Sensors, Monitors and Transducers
Services
Software
Test and Measuring Instruments
Textile Industry Products
Thermal and Heating Equipment
Timers and Clocks
Transportation Industry Products
Vision Systems
Waste Handling Equipment
Welding Equipment and Supplies
 Press Releases
Products in the News
Company News
Mergers & Acquisitions
People in the News
Literature & Websites
 Resources
News Delivery Options
Browse Categories
Browse Companies
Mobile Edition
PR Resources
Licensing
Advertising
How to Write an effective Press Release
Trade Associations
Small Business Support
MEP

Advertisement
Chemicals & Chemical Processing -> Sampling Devices -> Other


Other


   Add to Google      PDF icon

(Showing headlines 21 - 40)   1 2 3

Fecal Parasite Concentrator eliminates need for solvents.

DiaSys Corp.
Waterbury, CT 06702
Dec 07, 2006 Without need for ethyl acetate or ether derived products, Parasep SF facilitates clean and efficient concentration of helminth ova and larvae as well as protozoal cysts and oocysts. Product's dual filter technology removes fecal debris and solubilizes fat content to prevent interference with resulting sediment. Providing clean sample with recovery of all parasite stages, Parasep also reduces operator risk and promotes safe disposal.

SPE Products suit pharamaceutical applications.

Varian, Inc.
Palo Alto, CA 94304
Nov 22, 2006 Bond Elut® Plexa(TM) polymeric solid phase extraction products deliver streamlined sample preparation process to pharmaceutical researchers involved in clinical and preclinical studies. Polymeric design, featuring hydroxylated exterior and polarity gradient within pores, maximizes extract cleanliness and analyte recovery, resulting in optimal analytical sensitivity and data quality.

FIB/SEM System offers nanoscale imaging and analysis.

FEI Co.
Hillsboro, OR 97124-5830
Sep 01, 2006 Helios NanoLab(TM) DualBeam(TM) features ultra-high resolution field emission scanning electron microscope (SEM) column combined with Sidewinder(TM) focused ion beam (FIB) column and gas chemistries to provide imaging resolution and contrast in DualBeam system. Small DualBeam platform enables 3D characterization, analysis, and image reconstruction applications, nano-prototyping (fabrication and testing) capabilities, and advanced sample preparation abilities.

Mini Gyratory Rocker has space-saving design.

Mini Gyratory Rocker has space-saving design.

SciLabware (formerly Barloworld Scientific)
Staffordshire ST15 0SA  United Kingdom
Jun 29, 2006 Suited for use on bench or in incubators, SSM3 produces gentle 3D gyratory rocking action for low foaming agitation, DNA extractions, staining, and de-staining procedures. Its 3° to 12° angle of tilt can be moved to any position by hand to optimize mixing of vessels. Along with digital speed control, unit features built-in timer, 9.25 in.˛ platform, and 5-70 rpm speed range. Optional SM3/1 tier system is available; each tier is held in place by magnets.

Ingredient Processing Workstations aid in drug formulation.

Caliper Life Sciences, Inc.
Hopkinton, MA 01748
Jun 21, 2006 Tabletop Models TPW3 and APW3 Tablet and Active Ingredient Processing Workstations perform fully automated sample preparation for common pharmaceutical development and quality assurance tests in regulatory compliant manner. System delivers precise control over dispersing and extracting, with gravimetric confirmation that assures liquid dispense accuracy. Units confirm to ATSM and USP requirements for volumetric delivery, precision, and accuracy.

Laboratory Freezer aids with sample preparation.

Laboratory Freezer aids with sample preparation.

Leica Microsystems, Inc.
Bannockburn, IL 60015
Apr 12, 2006 Model EM PACT2 Freezer is designed to help researchers achieve reproducible results for localization and characterization of organelles and subcellular components. High-pressure system allows freezing up to 200 µm into specimen for subsequent sectioning and observation, and menu-driven color touchscreen guides user through fresh to frozen process in 5 sec. After freezing, pressure and temperature curves can be observed, stored, and downloaded to PC.

Gas Analysis Sampling System offers stack mounting option.

Gas Analysis Sampling System offers stack mounting option.

Perma Pure Inc.
Toms River, NJ 08754
Mar 10, 2006 Housed in NEMA 4X rated enclosure, GASS(TM)-2040 prepares gas samples for analysis, removing acid mists, coalescable liquids, water, and particulates without altering concentrations of analyte gases such as CO, CO2, HCl, NOX, O2 and SO2. It processes samples containing 50% water at rates of up to 25 L/min, removing particulates as small as 1 µm, and reducing water content to dew point of -25°C. Heated coalescing filter with automatic drain removes acid mists before drying.

SPE Formats assist bioanalytical sample preparation.

Varian, Inc.
Palo Alto, CA 94304
Feb 06, 2006 OMIX® micro extraction solid phase extraction formats for bioanalytical research feature monolithic sorbent technology that allows for extractions with low elution volumes. OMIX micro extraction pipette tips enable vacuum-free SPE processing of biofluid samples directly in pipette tips. OMIX 96-well plate is designed to process small sample volumes in SBS-compatible device which interfaces with standard 96-well liquid-handling equipment.

Diluter/Dispenser facilitates sample preparation process.

Diluter/Dispenser facilitates sample preparation process.

Valco Instrument Co., Inc.
Houston, TX 77255
Jan 30, 2006 Built around syringe-free, bi-directional, positive displacement pump, Cheminert M Series includes Model M10 with flow range of 10 nl to 10 ml and Model M50 with range of 50 µl to 50 ml. Wizard format eliminates math calculations and external charts. Users enter dilution ratio and final volume, and correct volume is calculated and automatically dispensed. Multiposition stream selection valve can be integrated with pump for multi-solvent applications.

Sample Preparation System facilitates molecular testing.

Beckman Coulter, Inc.
Fullerton, CA 92834-3100
Jan 05, 2006 Based on Biomek® automation and diagnostic primary tube handling technologies, Vidiera(TM) NsP Nucleic Sample Preparation platform provides nucleic acid isolation, quantification, normalization, and reaction set-up for downstream assay analysis. Suited for molecular diagnostic applications in virology and pathology, Vidiera NsP enables hospital and reference labs to centralize pre-analytical functions in one room and streamline process.

Gas Dryers handle flows up to 1 lpm.

Gas Dryers handle flows up to 1 lpm.

Perma Pure Inc.
Toms River, NJ 08754
Nov 08, 2005 Designed to dry hot, wet, sample gases prior to analysis, MDH(TM) Series combines heating element with Nafion® technology, which selectively removes only water from sample gases, leaving rest of gas sample unaffected. Dryers remove water directly from vapor phase, preventing loss of water-soluble gases through dissolution in condensate. Units can dry gases with as much as 30% water by volume and use built-in thermostat to prevent condensation throughout drying process.

Micro Sample Preparation Tools deliver precision cutting.

Micro Sample Preparation Tools deliver precision cutting.

JASCO, Inc.
Easton, MD 21601
Oct 18, 2005 SliceMaster HS-1 Vertical Slicer is capable of cutting various materials in thin sections from 100-600 µm, depending on material, with variable thickness selection. Capable of cutting samples at 15° angle, HK-1 Angled Slicer handles thicknesses from 60-140 µm. Model HW-1 Multi-angle Slicer, capable of cutting samples at any angle from 45-90°, allows user to view slicing process of samples with microscope. It provides thin sections from 10-500 µm.

Dry Bath controls temperatures from -10 to +100°C.

Dry Bath controls temperatures from -10 to +100°C.

Torrey Pines Scientific, Inc.
San Marcos, CA 92069
Jan 03, 2005 EchoTherm™ Model IC20 can freeze, chill, or heat samples in assay plates, centrifuge tubes, vials, and test tubes. Peltier driven unit measures 6.5 x 8.75 x 3.5 in. and comes with chiller/heater module, UPS, and ac line cord. It provides digital display and control of temperature to 1°C; count down timer in days, hours, minutes and seconds to 30 days; data logger; and RS232 interface. Product is suited for various uses in molecular biology labs.

Analytic Extractor suits bioanalytical sample preparation.

Argonaut Technologies
Redwood City, CA 94063
Nov 17, 2004 EVOLUTE ABN (Acidic Basic Neutral) provides means to extract drugs from biological fluids through solid phase extraction (SPE). Able to process plasma extracts and quantify drug concentrations using LC-MS/MS analysis, product reduces problems of ion suppression and matrix effects. EVOLUTE ABN SPE columns and 96-well plates use polymer-based sorbent to facilitate separation of unneeded matrix materials from analytes.

Sample Preparation System suits range of polymer types.

Sample Preparation System suits range of polymer types.

Polymer Laboratories, Inc.
Amherst, MA 01002
Oct 01, 2004 Intended for manual dissolution and filtration of samples prior to GPC analysis, Model PL-SP 260VS combines controlled heating across temperature range of 30–260°C with gentle agitation and user-selectable speeds between 85–230 rpm. Pipettor device dispenses hot filtered sample solution from preparation vial directly into destination vials, with minimal handling. Choice of filtration media includes 1µm glass fiber and porous stainless steel.

Gas Sampling System is probe mounted.

Gas Sampling System is probe mounted.

Perma Pure Inc.
Toms River, NJ 08754
Jul 22, 2004 Designed to prepare wet, hot, and dirty stack gases for analysis, 1640 Mini-GASS (Gas Analysis Sampling System) allows users to accurately monitor smoke stack emissions. Gas conditioning system extracts sample gas via integrated sample probe and passes it through series of filters, scrubbers, and dryers. Housed in stainless steel cabinet, components remove water, acid mist, and ash without altering concentrations of gases to be analyzed.

Sample Conditioning Modules provide single-point sampling.

Sample Conditioning Modules provide single-point sampling.

Waters Equipment Co.
Lansdale, PA 19446 0576
Jul 14, 2003 Series 3100 provides tool for lowering temperature and pressure of single samples in power plants and boiler rooms. Units handle sample conditions up to 5,000 psig at 1,000°F. Sample flows up to 1,500 cc/min and beyond are capable of being cooled to within degrees of cooling water temperature due to high-efficiency coolers. Carbon-steel or optional stainless-steel backplate allows for mounting to plant's control panel or suitable structure.

Sample Cutter handles soft, moist foods and materials.

Sample Cutter handles soft, moist foods and materials.

Bel-Art Products
Pequannock, NJ 07440 1920
Apr 23, 2003 Molded of polycarbonate, Scienceware® Sample Cutter is a three tined fork constructed with sharp rocker knife on its back edge. Product has sturdy handle for positive grip when manipulating tough samples. Cutter, measuring 7.5 in. long, can be safely autoclaved at 250°F or cleaned using commercial dishwasher.

Automatic Drawdown Machine is suited for laboratory use.

Automatic Drawdown Machine is suited for laboratory use.

Paul N. Gardner Co., Inc.
Pompano Beach, FL 33060 6608
Oct 29, 2002 AUTO-DRAW(TM) III motorized laboratory drawdown machine eliminates human variables to create laboratory precision samples. Able to control speed and direction, unit produces samples up to 8˝ x 13 in. at 47 in./minute rate. Machine offers 1-switch control knob.

Disrupter Press disintegrates cells.

Disrupter Press disintegrates cells.

Thermo Spectronic
Rochester, NY 14625
Apr 23, 2002 Enhancements to FRENCH(R) Press include startup kits and valves. Start Up Kit and Miniature 20K Start Up Kit both include motor driven Laboratory Press, spare parts kit, and cell filling stand. Valves include Press Flow Valve and Press O-ring Stem Valve, both for Standard 40K pressure cell. Press and pressure cells are used for disintegration of chloroplast materials, blood cells, unicellular organisms, and other biological particles.




(Showing headlines 21 - 40)   1 2 3


ThomasNet News Advertisers





Fybroc - World Leader in Thermoset Pumps for Corrosive & Abrasive Liquids
Home  |  My ThomasNet News  |  Industry Market Trends  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2009 Thomas Publishing Company
Terms of Use - Privacy Policy