Advertisement
|
|
Chemicals & Chemical Processing ->
Other
Other
(Showing headlines 21 - 38) 1 2
|
 Solvent Reclaiming Systems recover up to 99.90% of solvent.NexGen Enviro Systems, Inc.
Lindenhurst, NY 11757
Feb 28, 2005 RESOLV-R 2® Model IST Series offers alternative to drum and haul services and ensures compliance with EPA standards for solvent handling and disposal. Available in 2.6, 4, 6.6, 11, and 16 gal capacities, systems provide automated cycling turnaround of 4–6 hr, which is controlled mechanically or by on-board 8-bit digital controller that also handles system diagnostics and maintenance alerts. Built-in forced air fan handles condenser vapor cooling. |
 Solvent Recycler replaces drum and haul services.NexGen Enviro Systems, Inc.
Lindenhurst, NY 11757
Feb 07, 2005 Resolv-R2 Model 90DIGIT standalone automated system provides solvent distilling cycle driven by 8-bit microprocessor. It can process 24 gal of solvent within 4–6 hours and recover 99.9% of reuseable solvent, which ensures compliance with EPA standards. On-board digital controller handles system diagnostics and provides alerts when operational maintenance is required. 90DIGIT measures 35 x 43 x 67 in., weighs 539 pounds, and operates at rated power of 8,000 W.
|
Chemical Monitor suits microelectronics manufacturers.Jetalon Solutions, Inc.
Campbell, CA 95008
Nov 08, 2004 Designed for monitoring and controlling concentrations of liquid chemicals, CR-288™ point-of-use system utilizes miniaturized optical reflectivity technology and delivers chemical information in fractions of 1 sec. Process Transparent Liquid Chemical Concentration System helps reduce wafer scrap, increase process control, and reduce chemical consumption. Real-time sensor measures 2 x 2 x 3 in. and has no moving parts. |
 Screenings Conditioner fits in tight plant locations.Franklin Miller Delumper Mixer Div.
Livingston, NJ 07039
May 17, 2004
SPIRALIFT® SC adds in-channel auger screening system to existing mechanical bar screen installation. Employing TASKMASTER® grinder, unit takes screenings from bar screen and washes, dewaters, compacts, and deposits them for disposal. PLC-based control system monitors and integrates entire system. Freestanding conditioner features stainless steel tank enclosure and hopper. It can be fixed mounted or configured for portable operation to handle output from multiple sources.
|
 Aerosol Can Processor offers automatic feeding.Teemark Corp.
Aitkin, MN 56431 9604
Nov 17, 2003 Able to process up to 800 aerosol cans per hour, explosion-proof Super 800 has air/hydraulic logic control system with minimal moving parts. Machine opens, empties, and crushes full or partially full cans of various sizes. VOCs can be collected by optional carbon filter built into crusher. |
 Solvent Recycler Series offers fully automatic operation.PBR Industries
Lindenhurst, NY 11757
Aug 08, 2003 Available in 37, 53, and 105 gal sizes, RESOLV-R2® ECO series is built to meet Class 1 Division 1 Group D Explosion Proof code requirements. Each model includes automatic cycle and is controlled by 8-bit processor. Reclaiming equipment consists of primary evaporation tank connected by rotating joints to secondary unit where solvent vapor is condensed. Waste solvent is automatically loaded, and level control device prevents overload condition. |
 UV Germicidal Irradiation System targets SARS in airstream.UltraViolet Devices, Inc.
Valencia, CA 91355
Jul 21, 2003 V-Flex™ high-intensity UV surface and air stream disinfection system offers 360° UVC irradiance, which targets microorganisms in moving airstreams. Product runs on V-Smart™ application software, which determines correct level of UVC needed to treat the target microbe. System demonstrated a predictive Severe Acute Respiratory Syndrome (SARS) disinfection rate of ~98% in 9,000 cfm air handling systems. |
 Solvent Recyclers offer digital and mechanical controls.PBR Industries
Lindenhurst, NY 11757
Mar 07, 2003 RESOLV-R2 Model IST comes in normal location or certified Class I Division Group D Explosion Proof design. Batch sizes include 2.6, 4, 6.6, 11 and 16 gal. Cycle is entirely automatic and averages 4 hrs. Safety controls monitor cycle and shut down unit when all solvent is evaporated. Recyclers are fan cooled to eliminate need for water. Tank is 304 SS and condensers are offered in copper or stainless steel as required. Electronics are 230 V, single phase. |
 Disposal System drains aerosol cans for recycling.Newstripe, Inc.
Aurora, CO 80011
Feb 07, 2003 Mounted on 20, 30, or 55 gal drums, AEROVENT 3 puntures and drains up to 3 aerosol cans in less than 10 sec. Fluids collect in drum, and cans may be disposed of as scrap steel. Non-sparking design includes carbide piercing tips and anti-static grounding cable. Built from structural steel, unit totally encloses cans being punctured, while vent carbon filter eliminates VOC and hydrocarbons from being released into atmosphere. |
 Distillation System handles ammonia, cyanide, and phenols.Kimble-Kontes
Vineland, NJ 08362-1502
Aug 28, 2002 Rated at 155 V and 1000 W, Midi-Vap 2000 supports semiautomatic colorimetry methods for drinking, ground, surface, saline, domestic, and industrial waste waters. Using up to 10, 50 mL sized samples, unit thermostatically controls temperatures to prevent overheating. Offerings include draft shield, parallel water manifold, and 120-minute timers. Also included: heat indicator lights, digital temperature controls, and vacuum PTFE needle valves. |
 Destruct System decomposes fully saturated ozone.IN USA, Inc.
Needham, MA 02494
Jul 05, 2002 TOD-O3 Thermal Ozone Destruct System destroys high concentration ozone vapors that offgas from wet bench and other semiconductor applications. It includes heat exchanger, coalescing filter, thermal cooling switch, and EMO. System is designed for mounting to ozone transfer module exhaust, and can accommodate flow rates of saturated ozone up to 20 SLPM @ 240 g/Nm³. There are no consumables required for operation. |
 Solvent Recovery Unit recycles paints/solvents.SIVA
Ocala, FL 34474
Apr 24, 2002 Model R-2A non-vacuum solvent recovery unit distills waste solvents with boiling points between 95 and 375 deg F. Cast-in aluminum heater provides enough heat to distill up to 4 gallons of solvent in 8 to 12 hours. |
 Separation System suits septage, food, and pulp products.Franklin Miller Delumper Mixer Div.
Livingston, NJ 07039
Apr 18, 2002
SPIRALIFT(TM) SR receives, screens, and separates solids from liquids. It incorporates fine screening shaftless screw system, spray wash, optional press zone, and integrated controls. System is housed in stainless steel tank enclosure with quick disconnect inlet flange for connection to septage trucks. Automatic inlet valve regulates internal fluid level. SPIRALIFT SR is available with one, 2, and 3 stages of solids separation.
|
 Mixer Reactor produces nanoparticles.Microfluidics, Division MFIC Corp.
Newton, MA 02464 9101
Apr 17, 2002 NMR high-intensity Multiple Stream Mixer Reactor produces uniform nanoparticles such as planarization media, superconductors, abrasive silica, recording media, photographic production and pharmaceutical products. Multiple streams of reactants, pressurized up to 40,000 psi, are fed in stoichiometric ratios into mixing chamber. Reactor uses computer controls to adjust multiple stream flow by keeping intensifier pumps operating in phase. |
 Vision Towers provide unobstructed site lines.Porta-King Building Systems
Earth City, MO 63045 1211
Mar 12, 2002 Vision Towers provide raised platforms, 4 to 15 ft above grade level, and are available in 3 types. DURASTEEL(TM) has seamless, steel construction for smooth panel finishes. DURASTEEL-PC(TM), with steel-pan construction, allows replacement of damaged wall panels. DURALUMINUM(TM) has clear anodized aluminum components. Buildings are available with spotlights, security screens, HVAC units, satellite glazing, and roll-down shutters. |
 Chemical Metering Pump operates at high pressure.LINC Mfg.
Conroe, TX 77303-5700
Mar 12, 2002 Pneumatically actuated 94P Series injects liquid chemical into process or pipeline. It injects bio-fluids into medication, dies and additive into food and beverages, dye into diesel fuel, and biocides, sulfides and amines into boilers. 1/4 in. and 1/2 in. plungers deliver pressures of 15,000 and 12,000 psi, respectively. Pump has abrasion-resistant ceramic plungers, dual seals, and floating piston for concentric stroke operation. |
 Chemical Monitoring System employs CVS technique.ECI Technology
East Rutherford, NJ 07073 1605
Mar 06, 2002 Quali-line QLC-6000 provides on-line chemical monitoring for copper electrodeposition process. Automatic system measures organic additives and inorganic components. Cyclic voltammetric stripping (CVS) technique offers logic based features and analysis development. QLC-6000's Microsoft® Windows® based platform supports GUI and touch screen monitors. |
Regenerative Thermal Oxidizer works without flush chambers.MEGTEC Systems
De Pere, WI 54115-5030
Dec 18, 2001 Cleanswitch™ RTO guarantees 99+% standard VOC destruction efficiency. Valve keeps treated air separate from dirty process air, so no significant amount of untreated air escapes when flow direction changes. By eliminating this puff of untreated air, it eliminates need for flush chambers. Under normal operating conditions, unit will run in a self-sustaining mode. No additional fuel is required to destroy VOCs. |
(Showing headlines 21 - 38) 1 2
|
|
|